960 research outputs found

    Myocardial changes in incident haemodialysis patients over 6-months:an observational cardiac magnetic resonance imaging study

    Get PDF
    Patients commencing on haemodialysis (HD) have an increased risk of cardiovascular events in the first year after starting HD compared to those patients established on HD longer. Left ventricular (LV) hypertrophy and abnormal myocardial strain predict mortality. There may be changes in the myocardium of incident HD patients over a 6-month period of HD which may explain changes in cardiovascular risk. We used CMR to consider changes in LV mass, myocardial strain and T1 mapping. We examined changes in pre-dialysis highly sensitive troponin T. 33 patients undergoing HD for <12 months were recruited. Participants underwent CMR at baseline and after 6-months of standard care. 6-months of HD was associated with reduction in LV mass index (Baseline: 78.8 g/m2 follow up: 69.9 g/m2, p = <0.001). LV global longitudinal strain also improved (Baseline: −17.9%, follow up: −21.6%, p = <0.001). Change in T1 time was not significant (Baseline septal T1 1277.4 ms, follow up 1271.5 p = 0.504). Highly sensitive troponin T was lower at follow up (Baseline 38.8 pg/L, follow up 30.8 pg/L p = 0.02). In incident HD patients, 6-months of HD was associated with improvements in LV mass, strain and troponin. These findings may reflect improvement in known cardiac tissue abnormalities found in patients over the first year of HD

    Postdialysis blood pressure rise predicts long-term outcomes in chronic hemodialysis patients: a four-year prospective observational cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The blood pressure (BP) of a proportion of chronic hemodialysis (HD) patients rises after HD. We investigated the influence of postdialysis BP rise on long-term outcomes.</p> <p>Methods</p> <p>A total of 115 prevalent HD patients were enrolled. Because of the fluctuating nature of predialysis and postdialysis BP, systolic BP (SBP) and diastolic BP before and after HD were recorded from 25 consecutive HD sessions during a 2-month period. Patients were followed for 4 years or until death or withdrawal.</p> <p>Results</p> <p>Kaplan-Meier estimates revealed that patients with average postdialysis SBP rise of more than 5 mmHg were at the highest risk of both cardiovascular and all-cause mortality as compared to those with an average postdialysis SBP change between -5 to 5 mmHg and those with an average postdialysis SBP drop of more than 5 mmHg. Furthermore, multivariate Cox regression analysis indicated that both postdialysis SBP rise of more than 5 mmHg (HR, 3.925 [95% CI, 1.410-10.846], <it>p </it>= 0.008) and high cardiothoracic (CT) ratio of more than 50% (HR, 7.560 [95% CI, 2.048-27.912], <it>p </it>= 0.002) independently predicted all-cause mortality. We also found that patients with an average postdialysis SBP rise were associated with subclinical volume overload, as evidenced by the significantly higher CT ratio (<it>p </it>= 0.008).</p> <p>Conclusions</p> <p>A postdialysis SBP rise in HD patients independently predicted 4-year cardiovascular and all-cause mortality. Considering postdialysis SBP rise was associated with higher CT ratio, intensive evaluation of cardiac and volume status should be performed in patients with postdialysis SBP rise.</p

    Potential role of differential medication use in explaining excess risk of cardiovascular events and death associated with chronic kidney disease: A cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Patients with chronic kidney disease (CKD) are less likely to receive cardiovascular medications. It is unclear whether differential cardiovascular drug use explains, in part, the excess risk of cardiovascular events and death in patients with CKD and coronary heart disease (CHD).</p> <p>Methods</p> <p>The ADVANCE Study enrolled patients with new onset CHD (2001-2003) who did (N = 159) or did not have (N = 1088) CKD at entry. The MDRD equation was used to estimate glomerular filtration rate (eGFR) using calibrated serum creatinine measurements. Patient characteristics, medication use, cardiovascular events and death were ascertained from self-report and health plan electronic databases through December 2008.</p> <p>Results</p> <p>Post-CHD event ACE inhibitor use was lower (medication possession ratio 0.50 vs. 0.58, P = 0.03) and calcium channel blocker use higher (0.47 vs. 0.38, P = 0.06) in CKD vs. non-CKD patients, respectively. Incidence of cardiovascular events and death was higher in CKD vs. non-CKD patients (13.9 vs. 11.5 per 100 person-years, P < 0.001, respectively). After adjustment for patient characteristics, the rate of cardiovascular events and death was increased for eGFR 45-59 ml/min/1.73 m<sup>2 </sup>(hazard ratio [HR] 1.47, 95% CI: 1.10 to 2.02) and eGFR < 45 ml/min/1.73 m<sup>2 </sup>(HR 1.58, 95% CI: 1.00 to 2.50). After further adjustment for statins, β-blocker, calcium channel blocker, ACE inhibitor/ARB use, the association was no longer significant for eGFR 45-59 ml/min/1.73 m<sup>2 </sup>(HR 0.82, 95% CI: 0.25 to 2.66) or for eGFR < 45 ml/min/1.73 m<sup>2 </sup>(HR 1.19, 95% CI: 0.25 to 5.58).</p> <p>Conclusions</p> <p>In adults with CHD, differential use of cardiovascular medications may contribute to the higher risk of cardiovascular events and death in patients with CKD.</p

    Hospitalization and mortality following non-attendance for hemodialysis according to dialysis day of the week : a European cohort study

    Get PDF
    Background The extension of the interdialytic interval due to due to dialysis session non-attendance varies according to which session of the week the patient misses. The impact of this on subsequent hospitalization and mortality is unknown. Methods The ARO cohort study prospectively collected data from hemodialysis patients across 15 European countries on demography, comorbidity, laboratory, hospitalisation, mortality and individual hemodialysis sessions from 2007 to 2014. Event rates for death and hospitalisation according to dialysis day of the week were calculated for patients who attended the three previous scheduled hemodialysis sessions, who then on the next scheduled dialysis day either attended or did not attend. The hazard ratio for these events following non-attendance for the first compared to the second dialysis session of the week was estimated using Cox proportional hazards model adjusted for patient demographics. Results 3.8 million hemodialysis sessions in 9397 patients were analysed. The non-attendance rates for Monday/Wednesday/Friday sessions were 0.8, 0.9% & 1.4% respectively, and for Tuesday/Thursday/Saturday sessions were 0.6, 1.0% & 1.2% respectively. Compared to those who attended, for the 48–72 h between non-attendance and the next scheduled haemodialysis session, mortality significantly increased from 4.86 to 51.9/100 pt-yrs and hospitalisation increased from 0.58 to 2.1/yr. As time from the two-day break increased, the risk associated with non-attendance lessened: compared to missing the second hemodialysis session, missing the first session had a hazard ratio for mortality of 2.04 (95% CI 1.27–3.29), and for hospitalisation 1.78 (95% CI 1.29–2.47). In patients who attended their scheduled dialysis session and the three preceding, after the two-day break there were absolute increases in mortality (8.3 vs. 4.9/100 pt-yrs) and hospitalisation (1.0 vs. 0.6/yr for the rest of the week) comparable to previous studies. Conclusions In addition to hospitalisation and mortality increases seen after the two-day break, additional harm may be manifested in the greater increases in mortality and hospitalisation observed after non-attendance for the first hemodialysis session after the two-day break compared to missing other sessions

    Electrocardiographic Left Ventricular Hypertrophy and Outcome in Hemodialysis Patients

    Get PDF
    BACKGROUND AND AIMS: Electrocardiography (ECG) is the most widely used initial screening test for the assessment of left ventricular hypertrophy (LVH), an independent predictor of cardiovascular mortality in patients with end-stage renal disease (ESRD). However, traditional ECG criteria based only on voltage to detect LVH have limited clinical utility for the detection of LVH because of their poor sensitivity. METHODS: This prospective observational study was undertaken to compare the prognostic significance of commonly used ECG criteria for LVH, namely Sokolow-Lyon voltage (SV) or voltage-duration product (SP) and Cornell voltage (CV) or voltage-duration product (CP) criteria, and to investigate the association between echocardiographic LV mass index (LVMI) and ECG-LVH criteria in ESRD patients, who consecutively started maintenance hemodialysis (HD) between January 2006 and December 2008. RESULTS: A total of 317 patients, who underwent both ECG and echocardiography, were included. Compared to SV and CV criteria, SP and CP criteria, respectively, correlated more closely with LVMI. In addition, CP criteria provided the highest positive predictive value for echocardiographic LVH. The 5-year cardiovascular survival rates were significantly lower in patients with ECG-LVH by each criterion. In multivariate analyses, echocardiographic LVH [adjusted hazard ratio (HR): 11.71; 95% confidence interval (CI): 1.57-87.18; P = 0.016] and ECG-LVH by SP (HR: 3.43; 95% CI: 1.32-8.92; P = 0.011) and CP (HR: 3.07; 95% CI: 1.16-8.11; P = 0.024) criteria, but not SV and CV criteria, were significantly associated with cardiovascular mortality. CONCLUSIONS: The product of QRS voltage and duration is helpful in identifying the presence of LVH and predicting cardiovascular mortality in incident HD patients

    Does publication bias inflate the apparent efficacy of psychological treatment for major depressive disorder? A systematic review and meta-analysis of US national institutes of health-funded trials

    Get PDF
    Background The efficacy of antidepressant medication has been shown empirically to be overestimated due to publication bias, but this has only been inferred statistically with regard to psychological treatment for depression. We assessed directly the extent of study publication bias in trials examining the efficacy of psychological treatment for depression. Methods and Findings We identified US National Institutes of Health grants awarded to fund randomized clinical trials comparing psychological treatment to control conditions or other treatments in patients diagnosed with major depressive disorder for the period 1972–2008, and we determined whether those grants led to publications. For studies that were not published, data were requested from investigators and included in the meta-analyses. Thirteen (23.6%) of the 55 funded grants that began trials did not result in publications, and two others never started. Among comparisons to control conditions, adding unpublished studies (Hedges’ g = 0.20; CI95% -0.11~0.51; k = 6) to published studies (g = 0.52; 0.37~0.68; k = 20) reduced the psychotherapy effect size point estimate (g = 0.39; 0.08~0.70) by 25%. Moreover, these findings may overestimate the "true" effect of psychological treatment for depression as outcome reporting bias could not be examined quantitatively. Conclusion The efficacy of psychological interventions for depression has been overestimated in the published literature, just as it has been for pharmacotherapy. Both are efficacious but not to the extent that the published literature would suggest. Funding agencies and journals should archive both original protocols and raw data from treatment trials to allow the detection and correction of outcome reporting bias. Clinicians, guidelines developers, and decision makers should be aware that the published literature overestimates the effects of the predominant treatments for depression

    Attainment of clinical performance targets and improvement in clinical outcomes and resource use in hemodialysis care: a prospective cohort study

    Get PDF
    BACKGROUND: Clinical performance targets are intended to improve patient outcomes in chronic disease through quality improvement, but evidence of an association between multiple target attainment and patient outcomes in routine clinical practice is often lacking. METHODS: In a national prospective cohort study (ESRD Quality, or EQUAL), we examined whether attainment of multiple targets in 668 incident hemodialysis patients from 74 U.S. not-for-profit dialysis clinics was associated with better outcomes. We measured whether the following accepted clinical performance targets were met at 6 months after study enrollment: albumin (≥4.0 g/dl), hemoglobin (≥11 g/dl), calcium-phosphate product (<55 mg(2)/dl(2)), dialysis dose (Kt/V≥1.2), and vascular access type (fistula). Outcomes included mortality, hospital admissions, hospital days, and hospital costs. RESULTS: Attainment of each of the five targets was associated individually with better outcomes; e.g., patients who attained the albumin target had decreased mortality [relative hazard (RH) = 0.55, 95% confidence interval (CI), 0.41–0.75], hospital admissions [incidence rate ratio (IRR) = 0.67, 95% CI, 0.62–0.73], hospital days (IRR = 0.61, 95% CI, 0.58–0.63), and hospital costs (average annual cost reduction = $3,282, P = 0.002), relative to those who did not. Increasing numbers of targets attained were also associated, in a graded fashion, with decreased mortality (P = 0.030), fewer hospital admissions and days (P < 0.001 for both), and lower costs (P = 0.029); these trends remained statistically significant for all outcomes after adjustment (P < 0.001), except cost, which was marginally significant (P = 0.052). CONCLUSION: Attainment of more clinical performance targets, regardless of which targets, was strongly associated with decreased mortality, hospital admissions, and resource use in hemodialysis patients

    Exploring haemodynamics of haemodialysis using extrema points analysis model

    Get PDF
    Background: Haemodialysis is a form of renal replacement therapy used to treat patients with end stage renal failure. It is becoming more appreciated that haemodialysis patients exhibit higher rates of multiple end organ damage compared to the general population. There is also a strong emerging evidence that haemodialysis itself causes circulatory stress. We aimed at examining haemodynamic patterns during haemodialysis using a new model and test that model against a normal control. Methods: We hypothesised that blood pressures generated by each heart beat constantly vary between local peaks and troughs (local extrema), the frequency and amplitude of which is regulated to maintain optimal organ perfusion. We also hypothesised that such model could reveal multiple haemodynamic aberrations during HD. Using a non-invasive cardiac output monitoring device (Finometer®) we compared various haemodynamic parameters using the above model between a haemodialysis patient during a dialysis session and an exercised normal control after comparison at rest. Results: Measurements yielded 29,751 data points for each haemodynamic parameter. Extrema points frequency of mean arterial blood pressure was higher in the HD subject compared to the normal control (0.761Hz IQR 0.5-0.818 vs 0.468Hz IQR 0.223-0.872, P < 0.0001). Similarly, extrema points frequency of systolic blood pressure was significantly higher in haemodialysis compared to normal. In contrary, the frequency of extrema points for TPR was higher in the normal control compared to HD (0.947 IQR 0.520-1.512 vs 0.845 IQR 0.730-1.569, P < 0.0001) with significantly higher amplitudes. Conclusion: Haemodialysis patients potentially exhibit an aberrant haemodynamic behaviour characterised by higher extrema frequencies of mean arterial blood pressure and lower extrema frequencies of total peripheral resistance. This, in theory, could lead to higher variation in organ perfusion and may be detrimental to vulnerable vascular beds
    corecore