1,610 research outputs found

    Optically Generated Ultrasound for Intracoronary Imaging

    Get PDF
    Conventional intravascular ultrasound (IVUS) devices use piezoelectric transducers to electrically generate and receive US. With this paradigm, there are numerous challenges that restrict improvements in image quality. First, with miniaturization of the transducers to reduce device size, it can be challenging to achieve the sensitivities and bandwidths required for large tissue penetration depths and high spatial resolution. Second, complexities associated with manufacturing miniaturized electronic transducers can have significant cost implications. Third, with increasing interest in molecular characterization of tissue in-vivo, it has been challenging to incorporate optical elements for multimodality imaging with photoacoustics (PA) or near-infrared spectroscopy (NIRS) whilst maintaining the lateral dimensions suitable for intracoronary imaging. Optical Ultrasound (OpUS) is a new paradigm for intracoronary imaging. US is generated at the surface of a fiber optic transducer via the photoacoustic effect. Pulsed or modulated light is absorbed in an engineered coating on the fiber surface and converted to thermal energy. The subsequent temperature rise leads to a pressure rise within the coating, which results in a propagating ultrasound wave. US reflections from imaged structures are received with optical interferometry. With OpUS, high bandwidths (31.5 MHz) and pressures (21.5 MPa) have enabled imaging with axial resolutions better than 50 μm and at depths >20 mm. These values challenge those of conventional 40 MHz IVUS technology and show great potential for future clinical application. Recently developed nanocomposite coating materials, that are highly transmissive at light wavelengths used for PA and NIRS light, can facilitate multimodality imaging, thereby enabling molecular characterization

    In Memoriam: Sidney George Shaw, DPhil (1948-2017)

    Get PDF

    A System Dynamics Approach for Modeling Return on Quality for ECS Industry

    Get PDF
    The Electronic Components and Systems industry (ECS) is characterized by long lead times and high market volatility. Besides fast technological development within this industry, cyclic market up- and downturns are influencing the semiconductor market. Therefore, adequate capacity and inventory management as well as continuous process improvements are important success factors for semiconductor companies to be competitive. In this study, the authors focus on a manufacturing excellence approach to increase front-end supply reliability and the availability of inventory within the customer order decoupling point. Here, development and manufacturing processes must be designed in a way that highest levels of product quality, flexibility, time and costs are reached. The purpose of this study is to explore the impact of return on quality in manufacturing systems. Therefore, multimethod simulation modelling including discrete-event and system dynamics simulation is applied

    Wall-less vascular poly(vinyl) alcohol gel ultrasound imaging phantoms using 3D printed vessels

    Get PDF
    Vascular phantoms are crucial tools for clinical training and for calibration and validation of medical imaging systems. With current methods, it can be challenging to replicate anatomically-realistic vasculature. Here, we present a novel method that enables the fabrication of complex vascular phantoms. Poly(vinyl alcohol) (PVA) in two forms was used to create wall-less vessels and the surrounding tissue mimicking material (TMM). For the latter, PVA cryogel (PVA-c) was used as the TMM, which was made from a solution of PVA (10% by weight), distilled water, and glass spheres for ultrasonic scattering (0.5% by weight). PVA-c is not water soluble, and after a freeze-thaw cycle it is mechanically robust. To form the wall-less vessels, vessel structures were 3D printed in water-soluble PVA and submerged in the aqueous solution of PVA-c. Once the PVA-c had solidified, the 3D printed PVA vessel structures were dissolved in water. Three phantoms were created, as initial demonstrations of the capabilities of this method: a straight vessel, a stenosed (narrowed), and a bifurcated (branched) vessel. Ultrasound images of the phantoms had realistic appearances. We conclude that this method is promising for creating wall-less, anatomically realistic, vascular phantoms

    The Impact of Global Warming and Anoxia on Marine Benthic Community Dynamics: an Example from the Toarcian (Early Jurassic)

    Get PDF
    The Pliensbachian-Toarcian (Early Jurassic) fossil record is an archive of natural data of benthic community response to global warming and marine long-term hypoxia and anoxia. In the early Toarcian mean temperatures increased by the same order of magnitude as that predicted for the near future; laminated, organic-rich, black shales were deposited in many shallow water epicontinental basins; and a biotic crisis occurred in the marine realm, with the extinction of approximately 5% of families and 26% of genera. High-resolution quantitative abundance data of benthic invertebrates were collected from the Cleveland Basin (North Yorkshire, UK), and analysed with multivariate statistical methods to detect how the fauna responded to environmental changes during the early Toarcian. Twelve biofacies were identified. Their changes through time closely resemble the pattern of faunal degradation and recovery observed in modern habitats affected by anoxia. All four successional stages of community structure recorded in modern studies are recognised in the fossil data (i.e. Stage III: climax; II: transitional; I: pioneer; 0: highly disturbed). Two main faunal turnover events occurred: (i) at the onset of anoxia, with the extinction of most benthic species and the survival of a few adapted to thrive in low-oxygen conditions (Stages I to 0) and (ii) in the recovery, when newly evolved species colonized the re-oxygenated soft sediments and the path of recovery did not retrace of pattern of ecological degradation (Stages I to II). The ordination of samples coupled with sedimentological and palaeotemperature proxy data indicate that the onset of anoxia and the extinction horizon coincide with both a rise in temperature and sea level. Our study of how faunal associations co-vary with long and short term sea level and temperature changes has implications for predicting the long-term effects of “dead zones” in modern oceans

    Characterizations of how species mediate ecosystem properties require more comprehensive functional effect descriptors

    Get PDF
    The importance of individual species in mediating ecosystem process and functioning is generally accepted, but categorical descriptors that summarize species-specific contributions to ecosystems tend to reference a limited number of biological traits and underestimate the importance of how organisms interact with their environment. Here, we show how three functionally contrasting sediment-dwelling marine invertebrates affect fluid and particle transport - important processes in mediating nutrient cycling - and use high-resolution reconstructions of burrow geometry to determine the extent and nature of biogenic modification. We find that individual functional effect descriptors fall short of being able to adequately characterize how species mediate the stocks and flows of important ecosystem properties and that, in contrary to common practice and understanding, they are not substitutable with one another because they emphasize different aspects of species activity and behavior. When information derived from these metrics is combined with knowledge of how species behave and modify their environment, however, detailed mechanistic information emerges that increases the likelihood that a species functional standing will be appropriately summarized. Our study provides evidence that more comprehensive functional effect descriptors are required if they are to be of value to those tasked with projecting how altered biodiversity will influence future ecosystems

    Micron resolution, high-fidelity three-dimensional vascular optical imaging phantoms

    Get PDF
    Microscopic and mesoscale optical imaging techniques allow for three-dimensional (3-D) imaging of biological tissue across millimeter-scale regions, and imaging phantom models are invaluable for system characterization and clinical training. Phantom models that replicate complex 3-D geometries with both structural and molecular contrast, with resolution and lateral dimensions equivalent to those of imaging techniques (<20  μm), have proven elusive. We present a method for fabricating phantom models using a combination of two-photon polymerization (2PP) to print scaffolds, and microinjection of tailored tissue-mimicking materials to simulate healthy and diseased tissue. We provide a first demonstration of the capabilities of this method with intravascular optical coherence tomography, an imaging technique widely used in clinical practice. We describe the design, fabrication, and validation of three types of phantom models: a first with subresolution wires (5- to 34-μm diameter) arranged circumferentially, a second with a vessel side-branch, and a third containing a lipid inclusion within a vessel. Silicone hybrid materials and lipids, microinjected within a resin framework created with 2PP, served as tissue-mimicking materials that provided realistic optical scattering and absorption. We demonstrate that optical phantom models made with 2PP and microinjected tissue-mimicking materials can simulate complex anatomy and pathology with exquisite detail

    Dynamic physiological temperature and pressure sensing with phase-resolved low-coherence interferometry

    Get PDF
    We report the development and characterisation of highly miniaturised fibre-optic sensors for simultaneous pressure and temperature measurement, and a compact interrogation system with a high sampling rate. The sensors, which have a maximum diameter of 250 µm, are based on multiple low-finesse optical cavities formed from polydimethylsiloxane (PDMS), positioned at the distal ends of optical fibres, and interrogated using phase-resolved low-coherence interferometry. At acquisition rates of 250 Hz, temperature and pressure changes of 0.0021 °C and 0.22 mmHg are detectable. An in vivo experiment demonstrated that the sensors had sufficient speed and sensitivity for monitoring dynamic physiological pressure waveforms. These sensors are ideally suited to various applications in minimally invasive surgery, where diminutive lateral dimensions, high sensitivity and low manufacturing complexities are particularly valuable

    Exercise therapy for chronic low back pain:protocol for an individual participant data meta-analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Low back pain (LBP) is one of the leading causes of disability and has a major socioeconomic impact. Despite a large amount of research in the field, there remains uncertainty about the best treatment approach for chronic LBP, and identification of relevant patient subgroups is an important goal. Exercise therapy is a commonly used strategy to treat chronic low back pain and is one of several interventions that evidence suggests is moderately effective.</p> <p>In parallel with an update of the 2005 Cochrane review, we will undertake an individual participant data (IPD) meta-analysis, which will allow us to standardize analyses across studies and directly derive results, and to examine differential treatment effects across individuals to estimate how patients’ characteristics modify treatment benefit.</p> <p>Methods/design</p> <p>We will use standard systematic review methods advocated by the Cochrane Collaboration to identify relevant trials. We will include trials evaluating exercise therapy compared to any or no other interventions in adult non-specific chronic LBP. Our primary outcomes of interest include pain, functional status, and return-to-work/absenteeism. We will assess potential risk of bias for each study meeting selection criteria, using criteria and methods recommended by the Cochrane BRG.</p> <p>The original individual participant data will be requested from the authors of selected trials having moderate to low risk of bias. We will test original data and compile a master dataset with information about each trial mapped on a pre-specified framework, including reported characteristics of the study sample, exercise therapy characteristics, individual patient characteristics at baseline and all follow-up periods, subgroup and treatment effect modifiers investigated. Our analyses will include descriptive, study-level meta-analysis and meta-regression analyses of the overall treatment effect, and individual-level IPD meta-analyses of treatment effect modification. IPD meta-analyses will be conducted using a one-step approach where the IPD from all studies are modeled simultaneously while accounting for the clustering of participants with studies.</p> <p>Discussion</p> <p>We will analyze IPD across a large number of LBP trials. The resulting larger sample size and consistent presentation of data will allow additional analyses to explore patient-level heterogeneity in treatment outcomes and prognosis of chronic LBP.</p
    corecore