470 research outputs found
A Strain Gauge Monitor (SGM) for Continuous Valve Gape Measurements In Bivalve Molluscs in Response to Laboratory Induced Diel-Cycling Hypoxia and pH
An inexpensive, laboratory-based, strain gauge valve gape monitor (SGM) was developed to monitor the valve gape behavior of bivalve molluscs in response to diel-cycling hypoxia. A Wheatstone bridge was connected to strain gauges that were attached to the shells of oysters (Crassostrea virginica). The recorded signals allowed for the opening and closing of the bivalves to be recorded continuously over two-day periods of experimentally-induced diel-cycling hypoxia and diel-cycling changes in pH. Here, we describe a protocol for developing an inexpensive strain gauge monitor and describe, in an example laboratory experiment, how we used it to measure the valve gape behavior of Eastern oysters (C. virginica), in response to diel-cycling hypoxia and cyclical changes in pH. Valve gape was measured on oysters subjected to cyclical severe hypoxic (0.6 mg/L) dissolved oxygen conditions with and without cyclical changes in pH, cyclical mild hypoxic (1.7 mg/L) conditions and normoxic (7.3 mg/L) conditions. We demonstrate that when oysters encounter repeated diel cycles, they rapidly close their shells in response to severe hypoxia and close with a time lag to mild hypoxia. When normoxia is restored, they rapidly open again. Oysters did not respond to cyclical pH conditions superimposed on diel cycling severe hypoxia. At reduced oxygen conditions, more than one third of the oysters closed simultaneously. We demonstrate that oysters respond to diel-cycling hypoxia, which must be considered when assessing the behavior of bivalves to dissolved oxygen. The valve SGM can be used to assess responses of bivalve molluscs to changes in dissolved oxygen or contaminants. Sealing techniques to better seal the valve gape strain gauges from sea water need further improvement to increase the longevity of the sensors
Vibration Isolation Design for the Micro-X Rocket Payload
Micro-X is a NASA-funded, sounding rocket-borne X-ray imaging spectrometer
that will allow high precision measurements of velocity structure, ionization
state and elemental composition of extended astrophysical systems. One of the
biggest challenges in payload design is to maintain the temperature of the
detectors during launch. There are several vibration damping stages to prevent
energy transmission from the rocket skin to the detector stage, which causes
heating during launch. Each stage should be more rigid than the outer stages to
achieve vibrational isolation. We describe a major design effort to tune the
resonance frequencies of these vibration isolation stages to reduce heating
problems prior to the projected launch in the summer of 2014.Comment: 6 pages, 7 figures, LTD15 Conference Proceeding
Vibration Isolation Design for the Micro-X Rocket Payload
Micro-X is a NASA-funded, sounding rocket-borne X-ray imaging spectrometer that will allow high precision measurements of velocity structure, ionization state and elemental composition of extended astrophysical systems. One of the biggest challenges in payload design is to maintain the temperature of the detectors during launch. There are several vibration damping stages to prevent energy transmission from the rocket skin to the detector stage, which causes heating during launch. Each stage should be more rigid than the outer stages to achieve vibrational isolation. We describe a major design effort to tune the resonance frequencies of these vibration isolation stages to reduce heating problems prior to the projected launch in the summer of 2014
Multiabsorber Transition-Edge Sensors for X-Ray Astronomy
We are developing arrays of position-sensitive microcalorimeters for future x-ray astronomy applications. These position-sensitive devices commonly referred to as hydras consist of multiple x-ray absorbers, each with a different thermal coupling to a single-transition-edge sensor microcalorimeter. Their development is motivated by a desire to achieve very large pixel arrays with some modest compromise in performance. We report on the design, optimization, and first results from devices with small pitch pixels (<75 m) being developed for a high-angular and energy resolution imaging spectrometer for Lynx. The Lynx x-ray space telescope is a flagship mission concept under study for the National Academy of Science 2020 decadal survey. Broadband full-width-half-maximum (FWHM) resolution measurements on a 9-pixel hydra have demonstrated E(FWHM) = 2.23 0.14 eV at Al-K, E(FWHM) = 2.44 0.29 eV at Mn-K, and E(FWHM) = 3.39 0.23 eV at Cu-K. Position discrimination is demonstrated to energies below <1 keV and the device performance is well-described by a finite-element model. Results from a prototype 20-pixel hydra with absorbers on a 50-m pitch have shown E(FWHM) = 3.38 0.20 eV at Cr-K1. We are now optimizing designs specifically for Lynx and extending the number of absorbers up to 25/hydra. Numerical simulation suggests optimized designs could achieve 3 eV while being compatible with the bandwidth requirements of the state-of-the art multiplexed readout schemes, thus making a 100,000 pixel microcalorimeter instrument a realistic goal
A New Class of Changing-Look LINERs
We report the discovery of six active galactic nuclei (AGN) caught "turning
on" during the first nine months of the Zwicky Transient Facility (ZTF) survey.
The host galaxies were classified as LINERs by weak narrow forbidden line
emission in their archival SDSS spectra, and detected by ZTF as nuclear
transients. In five of the cases, we found via follow-up spectroscopy that they
had transformed into broad-line AGN, reminiscent of the changing-look LINER
iPTF 16bco. In one case, ZTF18aajupnt/AT2018dyk, follow-up HST UV and
ground-based optical spectra revealed the transformation into a narrow-line
Seyfert 1 (NLS1) with strong [Fe VII, X, XIV] and He II 4686 coronal lines.
Swift monitoring observations of this source reveal bright UV emission that
tracks the optical flare, accompanied by a luminous soft X-ray flare that peaks
~60 days later. Spitzer follow-up observations also detect a luminous
mid-infrared flare implying a large covering fraction of dust. Archival light
curves of the entire sample from CRTS, ATLAS, and ASAS-SN constrain the onset
of the optical nuclear flaring from a prolonged quiescent state. Here we
present the systematic selection and follow-up of this new class of
changing-look LINERs, compare their properties to previously reported
changing-look Seyfert galaxies, and conclude that they are a unique class of
transients well-suited to test the uncertain physical processes associated with
the LINER accretion state.Comment: Submitted to ApJ, 31 pages, 17 Figures (excluding Appendix due to
file size constraints but will be available in electronic version
The Magnetically-Tuned Transition-Edge Sensor
We present the first measurements on the proposed magnetically-tuned superconducting transition-edge sensor (MTES) and compare the modified resistive transition with the theoretical prediction. A TES's resistive transition is customarily characterized in terms of the unit less device parameters alpha and beta corresponding to the resistive response to changes in temperature and current respectively. We present a new relationship between measured IV quantities and the parameters alpha and beta and use these relations to confirm we have stably biased a TES with negative beta parameter with magnetic tuning. Motivated by access to this new unexplored parameter space, we investigate the conditions for bias stability of a TES taking into account both self and externally applied magnetic fields
HIV-1 protease inhibitors and clinical malaria: A secondary analysis of the AIDS Clinical Trials Group A5208 study
HIV-1 protease inhibitors (PIs) have antimalarial activity in vitro and in murine models. The potential beneficial effect of HIV-1 PIs on malaria has not been studied in clinical settings. We used data from Adult AIDS Clinical Trials Group A5208 sites where malaria is endemic to compare the incidence of clinically diagnosed malaria among HIV-infected adult women randomized to either lopinavir/ritonavir (LPV/r)-based antiretroviral therapy (ART) or to nevirapine (NVP)-based ART. We calculated hazard ratios and 95% confidence intervals. We conducted a recurrent events analysis that included both first and second clinical malarial episodes and also conducted analyses to assess the sensitivity of results to outcome misclassification. Among the 445 women in this analysis, 137 (31%) received a clinical diagnosis of malaria at least once during follow-up. Of these 137, 72 (53%) were randomized to LPV/r-based ART. Assignment to the LPV/r treatment group (n = 226) was not consistent with a large decrease in the hazard of first clinical malarial episode (hazard ratio = 1.11 [0.79 to 1.56]). The results were similar in the recurrent events analysis. Sensitivity analyses indicated the results were robust to reasonable levels of outcome misclassification. In this study, the treatment with LPV/r compared to NVP had no apparent beneficial effect on the incidence of clinical malaria among HIV-infected adult women. Additional research concerning the effects of PI-based therapy on the incidence of malaria diagnosed by more specific criteria and among groups at a higher risk for severe disease is warranted. Copyrigh
Measuring and Examining the Relevance of Discretionary Corporate Social Responsibility in Tourism: Some Preliminary Evidence From The UK Conference Sector
This article investigates the implementation of environmentally focused discretionary corporate social responsibility (CSR) within the U.K. conference sector. A new framework is proposed that organizes and communicates information detailing business performance regarding 10 environmental policy initiatives (expressed by the acronym GREENER) using a CSR response scale (expressed by the acronym VENUE). This GREENER VENUE framework fills a void in the CSR literature by focusing on discretionary practices, by exhibiting psychometric and conceptual properties enabling its application within a multitude of contexts. Grounded in theory, the framework is simple to implement, practical, easily understandable, and highly relatable. Applying the GREENER VENUE framework to data collected via a self-administered Internet questionnaire of the U.K. conference sector reveals the majority of conference venues are classified as Eager. The study also examines the efficacy of the proposed framework toward influencing U.K. venues’ performance on a range of environmentally friendly best practices relative to environmental accreditation
Suzaku Observations of HESS J1616-508: Evidence for a Dark Particle Accelerator
We observed the bright unidentified TeV gamma-ray source HESS J1616-508 with
the X-ray Imaging Spectrometers onboard the Suzaku satellite. No X-ray
counterpart was found to a limiting flux of 3.1e-13 erg/s/cm^2 in the 2--10 keV
band, which is some 60 times below the gamma-ray flux in the 1--10 TeV band.
This object is bright in TeV gamma-rays but very dim in the X-ray band, and
thus is one of the best examples in the Galaxy of a "dark particle
accelerator." We also detected soft thermal emission with kT=0.3--0.6 keV near
the location of HESSJ1616. This may be due to the dust grain scattering halo
from the nearby bright supernova remnant RCW103.Comment: 10 pages, 9 figures. Accepted for publication in PASJ Suzaku Special
Issue (vol. 59 sp. 1
The Detector Subsystem for the SXS Instrument on the Astro-H Observatory
The Soft X-ray Spectrometer (SXS) instrument on the Astro-H observatory is based on a 36 pixel x-ray calorimeter array cooled to 50 mK in a sophisticated spaceflight cryostat. The SXS is a true spatial-spectral instrument, where each spatially discrete pixel functions as a high-resolution spectrometer. Here we discuss the SXS detector subsystem that includes the detector array, the anticoincidence detector, the first stage amplifiers, the thermal and mechanical staging of the detector, and the cryogenic bias electronics. The design of the SXS detector subsystem has significant heritage from the Suzaku/XRS instrument but has some important modifications that increase performance margins and simplify the focal plane assembly. Notable improvements include x-ray absorbers with significantly lower heat capacity, improved load resistors, improved thermometry, and a decreased sensitivity to thermal radiation. These modifications have yielded an energy resolution of 3.5-4.0 eV FWHM at 6 keV for representative devices in the laboratory, giving considerable margin against the 7 eV instrument requirement. We expect similar performance in fligh
- …