34 research outputs found

    Structural recycled aggregate concrete made with precast wastes

    Get PDF
    This paper presents the main results of the characterization of recycled aggregate concrete made with precast structural concrete wastes as a case study. The use of recycled aggregates presents two main benefits. On the one hand, there would be an economic and environmental saving because it would not need to deposit waste in landfills. On the other hand, there would be a further economic and environmental saving because it would reduce the need for natural aggregate. However, because of the need of a greater amount of cement not all degrees of substitution present advantages. The results were obtained from four degrees of substitution and different mixing proportions and methods using natural and recycled aggregates and superplasticizers. After obtaining the optimal mixing proportions, the concretes have been fully characterised performing mechanical and durability tests, the methods analysed and the results compared with the literature

    Procedimiento y aparato para medir la deformación en un ensayo de tracción.

    Get PDF
    La presente invención se refiere a un procedimiento para medir la deformación en un ensayo de tracción, así como al dispositivo mediante el que se desarrolla dicho procedimiento. El método consiste en la medición de la deformación a partir del desplazamiento de dos puntos por medio de sensores láser colocados paralelamente al eje de la probeta. Estos van montados sobre un soporte articulado que se amarra a la máquina de ensayo. El dispositivo se completa con dos topes que colocados sobre la probeta sirven de diana para los sensores. El dispositivo permite: realizar medidas sin contacto con la probeta, para prevenir posibles daños en la rotura de la misma; calcular automático de la base de medida del extensómetro, sin medidas iniciales; medir de forma directa, sin calibración previa y tiene la posibilidad de medir con mucha precisión en recorridos cortos o grandes elongaciones con menor precisión.Solicitud: 200900178 (16.01.2009)Nº Pub. de Solicitud: ES2324696A1 (12.08.2009)Nº de Patente: ES2324696B2 (12.01.2010

    Método de medida de la permeabilidad de un material a un gas

    Get PDF
    Método de medición de la permeabilidad de un material a un gas, que comprende las etapas de: preparación de una probeta de un material cuya permeabilidad a un gas se va a medir; situar dicha probeta en un dispositivo configurado para mantener selladas sus caras laterales; conectar al menos un medio de almacenamiento de gas al extremo de la probeta por el cual entra el gas; conectar un caudalímetro al extremo de la probeta por el cual sale el gas; conectar la salida de un detector de flujo másico comprendido en el caudalímetro a unos medios de conversión de datos conectados a un ordenador; seleccionar al menos tres valores de presión de entrada en un manómetro-regulador; para cada presión de entrada, realizar con el caudalímetro al menos una medida del caudal que atraviesa la probeta, y obtener el coeficiente de permeabilidad K, sustituyendo el valor de caudal promedio en la ecuación de Darcy; obtener el coeficiente de permeabilidad de la probeta a partir del valor promedio de los coeficientes de permeabilidad K.Solicitud: 201300198 (19.02.2013)Nº Pub. de Solicitud: ES2406360A1 (06.06.2013)Nº de Patente: ES2406360B1 (04.03.2014

    Caudalímetro para la determinación de la permeabilidad de un material a un gas

    Get PDF
    Caudalímetro para la medición de la permeabilidad de un material a un gas, que comprende una entrada (configurada para recibir un gas que previamente ha atravesado una probeta de un material cuya permeabilidad a dicho gas se va a medir. Dicho caudalímetro comprende un detector de flujo másico configurado para convertir la cantidad de flujo de gas en un determinado parámetro, donde dicho flujo de gas puede tener un caudal del orden de las centésimas de cm3/s o superior.Solicitud: 201300197 (19.02.2013)Nº Pub. de Solicitud: ES2400592A1 (10.04.2013)Nº de Patente: ES2400592B1 (11.11.2013

    Sistema para la determinación de la permeabilidad de un material a un gas

    Get PDF
    Sistema de medición de la permeabilidad de un material a un gas, que comprende al menos un medio de almacenamiento de gas, unido mediante al menos un medio de transporte configurado para hacer circular el gas en su interior, a uno de los extremos de una probeta de un material cuya permeabilidad a dicho gas se va a medir, situada en el interior de un dispositivo configurado para mantener selladas las caras laterales de la probeta asegurando su estanqueidad y permitiendo la entrada de gas por uno de los extremos de dicha probeta y la salida por el extremo opuesto. El extremo opuesto de dicha probeta está unido mediante un medio de transporte configurado para hacer circular el gas en su interior, a un caudalímetro que comprende un detector de flujo másico encargado de convertir la cantidad de flujo de gas a la salida de la probeta en un determinado parámetro.Solicitud: 201300196 (19.02.2013)Nº Pub. de Solicitud: ES2406386A1 (06.06.2013)Nº de Patente: ES2406386B1 (04.03.2014

    Micro- and macro-porosity of dry- and saturatedstate recycled aggregate concrete

    Get PDF
    Society is becoming aware of the environment and progressively using more recycled aggregates to produce recycled structural aggregate concrete. In addition, many researches have analysed the properties of hardened recycled aggregate concrete, but few of them have focused on the mixing method and the consequences that it has on the properties of concrete. In this research, recycled aggregate concrete using dry, with extra water supply, and saturated recycled aggregate has been prepared. The different mixing conditions induce differences the micro and macroporosity of concrete that have been evaluated by computerized axial tomography, scanning electron microscopy and a new developed methodology, based on digital image analysis, developed to analyse the distribution and size of macroporosity. The software has been implemented in Matlab© and is available to the readers of the journal for downloading and use. The results show that the dry and saturated recycled aggregate lead to very different concrete properties. On the one hand, the use of dry aggregate causes a local reduction of the w/c ratio, increasing heterogeneity and decreasing workability. On the other hand, the saturated aggregate incorporates extra water by adsorption that causes an increase in the water/cement ratio, thus increasing the porosity volume and size of the new mortar of the recycled aggregate concrete

    Quasidistributed fiber sensor for precast concrete structures monitoring

    Get PDF
    The prestressing force is transferred to the concrete during the slack period of precast concrete structures fabrication. To contribute to a better understanding of the armor compliant behaviors during the mentioned process, a custom quasidistributed Bragg Grating optical fiber sensor system is designed, fabricated and embedded into a prestressed concrete prismatic beam. The experimental works, the results, their discussion and finally the obtained conclusions are presented in this paper.This work has been supported by the the project TEC2010-20224-C02- 02 and the grant AP2009-140

    Aparato y procedimiento para medir la deformación en un ensayo de tracción.

    Get PDF
    Aparato para medir la deformación por tracción de una probeta, que comprende: un brazo articulado configurado para fijarse a una máquina de ensayo, donde dicho brazo articulado comprende al menos dos tramos rígidos, y medios de anclaje; una guía montada en un extremo del segundo tramo del brazo articulado. Sobre dicha guía están montados dos bastidores en forma de "U", donde cada uno de dichos bastidores porta un sensor óptico respectivo, cada uno de los cuales tiene capacidad para desplazarse a lo largo de dicha guía; donde en el interior de la "U" de dichos soportes se aloja una probeta, incluyendo dos objetivo fijables a dicha probeta, estando dichos objetivos configurados para mediar la deformación de dicha probeta mediante la medición por parte de dichos sensores ópticos del desplazamiento de dichos objetivos.Solicitud: 201100377 (28.03.2011)Nº Pub. de Solicitud: ES2364212A1 (29.08.2011)Nº de Patente: ES2364212B1 (06.07.2012

    Influence of curing conditions on recycled aggregate concrete

    Get PDF
    This paper presents the results of a study of permeability and its influence on the durability of recycled concrete exposed to an aggressive environment. Recycled concretes with 20%, 50% and 100% in weight ofrecycled aggregate and 24 effective w/c ratios have been exposed directly to a marine environment. Control specimens cured in a humidity chamber have been also tested in order to compare the influence of the curing environment. The durability of recycled aggregate concretes exposed to aggressive conditions decreases in terms of permeability, as the results show. However, the influence of the environment on the recycled concrete also depends on the quality of the cement paste. The differences between the control and the exposed concrete are lower for low water/cement (w/c) ratios. The lower capillarity obtained in the new cement paste of the recycled concretes with low w/c ratios isolates the porosity of the recycled aggregate, increasing the durability but with a rise in the cement content.The authors wish to thank the Spanish Ministry of the Environment for the funding of this research. The results contained herein have been achieved under the RECNHOR Project (funded by the Spanish Ministry of Environment) and under the CLEAM Project (funded by the Spanish Centre for Industrial Technology Development, CDTI), Code 3.2-358/200 5/3-B, led by the Economic InterestGrouping CLEAM-CENIT, AIE (Acciona, Dragados, Ferrovial, FCC,Sioux, OHL and Sacyr) and SMEs Informatica 68, Quilosa and Martinez Segovia and associates

    Optical fiber sensor for prestressed concrete structures bond behaviors measurements

    Get PDF
    During the slack period of precast concrete structures fabrication, the prestressing force is transferred, by adhesion to concrete being the armor compliant behaviors, up today, a still pending matter. To contribute to a better understanding of the subject, a new quasi-distributed optical fiber sensor system is specifically designed, fabricated and embedded into a prestressed concrete prismatic beam. The experimental results are presented, discussed and finally, conclusions are extracted. The fiber transducer is based on Brag grating technology and a new custom encapsulation.This work has been supported by the project TEC2010-20224-C02-02 and grant AP2009-1403
    corecore