Optimization of operation and test of large size GEM detectors
We describe basic development work aimed at the realization of large (~1000 cm2 active) detectors for the COMPASS experiment, based on the gas electron multiplier technology. Essentially a high-rate forward spectrometer, the experiment requires high accuracy tracking of scattered particles and light detectors, in order not to degrade mass resolution and particle identification. The choice of a double GEM structure with two-coordinate read-out fulfils the above requirements. Systematic studies confirm the required performances, with good safety margins for an operation in harsh environments. We discuss the design problems encountered in the construction of the large devices and the solutions adopted, together with preliminary results obtained with prototypes in the laboratory and in a high intensity beam
Development and test of large size GEM detectors
We discuss the main operating features of GEM detectors, optimized for use as trackers in a high radiation environment. The construction, tests and performances of large prototypes for the COMPASS experiment are also described, as well as the results of an exposure to very high intensity beams. (11 refs)
Emerging Microfluidic Tools for Simultaneous Exosomes and Cargo Biosensing in Liquid Biopsy: New Integrated Miniaturized FFF-Assisted Approach for Colon Cancer Diagnosis
The early-stage diagnosis of cancer is a crucial clinical need. The inadequacies of surgery tissue biopsy have prompted a transition to a less invasive profiling of molecular biomarkers from biofluids, known as liquid biopsy. Exosomes are phospholipid bilayer vesicles present in many biofluids with a biologically active cargo, being responsible for cell-to-cell communication in biological systems. An increase in their excretion and changes in their cargo are potential diagnostic biomarkers for an array of diseases, including cancer, and they constitute a promising analyte for liquid biopsy. The number of exosomes released, the morphological properties, the membrane composition, and their content are highly related to the physiological and pathological states. The main analytical challenge to establishing liquid biopsy in clinical practice is the development of biosensors able to detect intact exosomes concentration and simultaneously analyze specific membrane biomarkers and those contained in their cargo. Before analysis, exosomes also need to be isolated from biological fluids. Microfluidic systems can address several issues present in conventional methods (i.e., ultracentrifugation, size-exclusion chromatography, ultrafiltration, and immunoaffinity capture), which are time-consuming and require a relatively high amount of sample; in addition, they can be easily integrated with biosensing systems. A critical review of emerging microfluidic-based devices for integrated biosensing approaches and following the major analytical need for accurate diagnostics is presented here. The design of a new miniaturized biosensing system is also reported. A device based on hollow-fiber flow field-flow fractionation followed by luminescence-based immunoassay is applied to isolate intact exosomes and characterize their cargo as a proof of concept for colon cancer diagnosis
Further developments of the gas electron multiplier (GEM)
We describe the development and operation of the Gas Electron Multiplier, a thin insulating foil metal-clad on both sides and perforated by a regular pattern of small holes. The mesh can be incorporat ed in the gas volume of an active detector to provide a first amplification channel for electrons, or used as stand alone. We report on the basic properties of GEMs manufactured with different geometr ies and operated in several gas mixtures as well as on their long-term stability after accumulation of charge equivalent to several years of operation in high luminosity experiments. Optimized GEMs re ach gains close to 10000 at safe operating voltages, permitting the detection of ionizing tracks, without other amplifying elements, on a simple printed circuit board (PCB), opening new possibilities for detector design
The CAST Time Projection Chamber
One of the three X-ray detectors of the CAST experiment searching for solar
axions is a Time Projection Chamber (TPC) with a multi-wire proportional
counter (MWPC) as a readout structure. Its design has been optimized to provide
high sensitivity to the detection of the low intensity X-ray signal expected in
the CAST experiment. A low hardware threshold of 0.8 keV is safely set during
normal data taking periods, and the overall efficiency for the detection of
photons coming from conversion of solar axions is 62 %. Shielding has been
installed around the detector, lowering the background level to 4.10 x 10^-5
counts/cm^2/s/keV between 1 and 10 keV. During phase I of the CAST experiment
the TPC has provided robust and stable operation, thus contributing with a
competitive result to the overall CAST limit on axion-photon coupling and mass.Comment: 19 pages, 11 figures and images, submitted to New Journal of Physic
Melatonin affects the motility and adhesiveness of in vitro capacitated boar spermatozoa via a mechanism that does not depend on intracellular ROS levels
This work sought to address the effects of melatonin during in vitro capacitation (IVC) and progesterone-induced acrosome exocytosis (IVAE) in boar spermatozoa. With this purpose, two different experiments were set. In the first one, IVC and IVAE were induced in the absence or presence of melatonin, which was added either at the start of IVC or upon triggering the IVAE with progesterone. Different parameters were evaluated, including intracellular levels of peroxides and superoxides, free cysteine radicals and distribution of specific lectins. While melatonin neither affected most capacitation-associated parameters nor IVAE, it dramatically decreased sperm motility, with a maximal effect at 5 µm. This effect was accompanied by a significant increase in the percentage of agglutinated spermatozoa, which was independent from noticeable changes in the distribution of lectins. Levels of free cysteine radicals were significantly lower in melatonin treatments than in the control after 4 h of incubation in capacitating medium. The second experiment evaluated the effects of melatonin on in vitro fertilising ability of boar spermatozoa. Spermatozoa previously subjected to IVC in the presence of 1 µm melatonin and used for in vitro fertilisation exhibited less ability to bind the zona pellucida (ZP) and higher percentages of monospermy. In conclusion, melatonin affects sperm motility and the stability of nucleoprotein structure and also modulates the ability of in vitro capacitated boar spermatozoa to bind the oocyte ZP. However, such effects do not seem to be related to either its antioxidant properties or changes in the sperm glycocalix
The Drift Chambers Of The Nomad Experiment
We present a detailed description of the drift chambers used as an active
target and a tracking device in the NOMAD experiment at CERN. The main
characteristics of these chambers are a large area, a self supporting structure
made of light composite materials and a low cost. A spatial resolution of 150
microns has been achieved with a single hit efficiency of 97%.Comment: 42 pages, 26 figure
Construction, test and commissioning of the triple-GEM tracking detector for COMPASS
The Small Area Tracking system of the COMPASS experiment at CERN includes a set of 20 large area, fast position-sensitive Gas Electron Multiplier (GEM) detectors, designed to reliably operate in the harsh radiation environment of the experiment. We describe in detail the design, choice of materials, assembly procedures and quality controls used to manufacture the devices. The test procedure in the laboratory, the performance in test beams and in the initial commissioning phase in the experiment are presented and discussed
Prospects for the CERN Axion Solar Telescope Sensitivity to 14.4 keV Axions
The CERN Axion Solar Telescope (CAST) is searching for solar axions using the
9.0 T strong and 9.26 m long transverse magnetic field of a twin aperture LHC
test magnet, where axions could be converted into X-rays via reverse Primakoff
process. Here we explore the potential of CAST to search for 14.4 keV axions
that could be emitted from the Sun in M1 nuclear transition between the first,
thermally excited state, and the ground state of 57Fe nuclide. Calculations of
the expected signals, with respect to the axion-photon coupling, axion-nucleon
coupling and axion mass, are presented in comparison with the experimental
sensitivity.Comment: 4 pages, 1 figure. Submitted to Nucl. Instr. and Meth.
X-ray emission during the muonic cascade in hydrogen
We report our investigations of X rays emitted during the muonic cascade in
hydrogen employing charge coupled devices as X-ray detectors. The density
dependence of the relative X-ray yields for the muonic hydrogen lines (K_alpha,
K_beta, K_gamma) has been measured at densities between 0.00115 and 0.97 of
liquid hydrogen density. In this density region collisional processes dominate
the cascade down to low energy levels. A comparison with recent calculations is
given in order to demonstrate the influence of Coulomb deexcitation.Comment: 5 pages, Tex, 4 figures, submitted to Physical Review Letter
- …