303 research outputs found

    Rationale, design and population baseline characteristics of the PERFORM Vascular Project: an ancillary study of the Prevention of cerebrovascular and cardiovascular Events of ischemic origin with teRutroban in patients with a history oF ischemic strOke or tRansient ischeMic attack (PERFORM) trial

    Get PDF
    <p><b>Purpose</b></p> <p>PERFORM is exploring the efficacy of terutroban versus aspirin for secondary prevention in patients with a history of ischemic stroke or transient ischemic attacks (TIAs). The PERFORM Vascular Project will evaluate the effect of terutroban on progression of atherosclerosis, as assessed by change in carotid intima-media thickness (CIMT) in a subgroup of patients.</p> <p><b>Methods and results</b></p> <p>The Vascular Project includes structural (CIMT, carotid plaques) and functional (carotid stiffness) vascular studies in all patients showing at least one carotid plaque at entry. Expected mean follow-up is 36 months. Primary endpoint is rate of change of CIMT. Secondary endpoints include emergent plaques and assessment of carotid stiffness. 1,100 patients are required for 90% statistical power to detect treatment-related CIMT difference of 0.025 mm. The first patient was randomized in April 2006.</p> <p><b>Conclusions</b></p> <p>The PERFORM Vascular Project will investigate terutroban’s effect on vascular structure and function in patients with a history of ischemic stroke or TIAs.</p&gt

    Low prevalence of significant carotid artery disease in Iranian patients undergoing elective coronary artery bypass

    Get PDF
    BACKGROUND: Coronary artery bypass grafting ranks as one of the most frequent operations worldwide. The presence of carotid artery stenosis may increase the stroke rate in the perioperative period. Routine preoperative noninvasive assessment of the carotid arteries are recommended in many institutions to reduce the stroke rate. METHODS: 271 consecutive patients undergoing coronary artery bypass grafting at Shaheed Madani hospital of Tabriz, Iran (age, 58.5 Y; 73.1% male) underwent preoperative ultrasonography for assessment of carotid artery wall thickness. RESULTS: Plaque in right common, left common, right internal and left internal carotid arteries was detected in 4.8%, 7.4%, 43.2% and 42.1% of patients respectively. 5 patients (1.8%) had significant (<50%) and 3 (1.1%) patients had critical (<70%) stenosis in internal carotid arteries. Plaque formation in common carotid was not significantly different between two genders but the stenosis of left internal carotid was more frequently seen among men. Patients with plaques in right or left internal carotid arteries were significantly older. CONCLUSION: Consecutive Iranian patients undergoing elective coronary artery bypass surgery show a very low prevalence of significant carotid artery disease

    Relationship between carotid intima-media thickness and coronary angiographic findings: a prospective study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Since cardiovascular diseases are associated with high mortality and generally undiagnosed before the onset of clinical findings, there is a need for a reliable tool for early diagnosis. Carotid intima-media thickness (CIMT) is a non-invasive marker of coronary artery disease (CAD) and is widely used in practice as an inexpensive, reliable, and reproducible method. In the current study, we aimed to investigate prospectively the relationship of CIMT with the presence and extent of significant coronary artery narrowing in patients evaluated by coronary angiography for stable angina pectoris.</p> <p>Methods</p> <p>One hundred consecutive patients with stable angina pectoris and documented ischemia on a stress test were included in the study. The patients were divided into two groups according to the result of the coronary angiography: group 1 (39 patients) without a noncritical coronary lesion, and group 2 (61 patients) having at least one lesion more than 50% within the main branches of the coronary arteries. All of the patients underwent carotid Doppler ultrasound examination for measurement of the CIMT by a radiologist blinded to the angiographic data.</p> <p>Results</p> <p>The mean CIMT was 0.78 ± 0.21 mm in Group 1, while it was 1.48 ± 0.28 mm in Group 2 (p = 0.001). The mean CIMT in patients with single vessel disease, multi-vessel disease, and left main coronary artery disease were significantly higher compared to Group 1 (1.2 ± 0.34 mm, p = 0.02; 1.6 ± 0.32 mm, p = 0.001; and 1.8 ± 0.31 mm, p = 0.0001, respectively). Logistic regression analysis identified CIMT (OR 4.3, p < 0.001) and hypertension (OR 2.4, p = 0.04) as the most important factors for predicting CAD.</p> <p>Conclusions</p> <p>The findings of this study show that increase in CIMT is associated with the presence and extent of CAD. In conclusion, we demonstrated the usefulness of carotid intima-media thickness in predicting coronary artery disease but large-scale studies are required to define its role in clinical practice.</p

    Carotid Artery Intima-Media Thickness, Carotid Plaque and Coronary Heart Disease and Stroke in Chinese

    Get PDF
    Background: Our aim was to prospectively investigate the association between carotid artery intima-media thickness (IMT) as well as carotid plaque and incidence of coronary heart disease (CHD) and stroke in Chinese, among whom data are limited. Methods and Findings: We conducted a community-based cohort study composed of 2190 participants free of cardiovascular disease at baseline in one community. During a median 10.5-year follow up, we documented 68 new cases of coronary heart disease and 94 cases of stroke. The multivariate relative risks (RRs) associated with a change of 1 standard deviation of maximal common carotid IMT were 1.38 (95% confidence interval [CI], 1.12–1.70) for CHD and 1.47 (95% CI, 1.28–1.69) for stroke. The corresponding RRs with internal carotid IMT were 1.47 (95% CI, 1.21–1.79) for CHD and 1.52 (95% CI, 1.31–1.76) for stroke. Carotid plaque measured by the degree of diameter stenosis was also significantly associated with increased risk of CHD (p for trend<0.0001) and stroke (p for trend<0.0001). However, these associations were largely attenuated when adjusting for IMT measurements. Conclusions: This prospective study indicates a significant association between carotid IMT and incidence of CHD and stroke in Chinese adults. These measurements may be useful for cardiovascular risk assessment and stratification in Chinese

    Ultrasound settings significantly alter arterial lumen and wall thickness measurements

    Get PDF
    Background. Flow-mediated dilation (FMD) and carotid intima-medial thickness (CIMT), measured by ultrasound, are widely used to test the efficacy of cardioprotective interventions. Although assessment methods vary, automated edge-detecting image analysis software is routinely used to measure changes in FMD and CIMT. We aimed to quantify the effect that commonly adjusted ultrasound settings have on arterial lumen and wall thickness measurements made with CIMT measurement software. Methods. We constructed phantom arteries from a tissue-mimicking agar compound and scanned them in a water bath with a 10 MHz multi-frequency linear-array probe attached to a high-resolution ultrasound machine. B-mode images of the phantoms were recorded with dynamic range (DR) and gain set at five decibel (dB) increments from 40 dB to 60 dB and -10 dB to +10 dB respectively. Lumen diameter and wall-thickness were measured off-line using CIMT measurement software. Results. Lumen measurements: there was a strong linear relationship between DR and gain and measured lumen diameter. For a given gain level, a 5 dB increase in DR reduced the measured lumen diameter by 0.02 ± 0.004 mm (p \u3c 0.001). For a given DR level, a 5 dB increase in gain reduced measured lumen diameter by 0.04 ± 0.004 mm (p \u3c 0.001). A 5 mm increase in distance between the ultrasound probe and the artery reduced measured lumen diameter by 0.04 ± 0.03 mm (p \u3c 0.001). CIMT measurements: For a fixed gain level, a 5 dB increase in DR increased measured wall thickness by 0.003 ± 0.002 mm (p \u3c 0.001). The effects of increasing gain were not consistent and appeared to vary depending on the distance between the artery and the ultrasound probe and the thickness of the artery wall. Conclusion. DR, gain and probe distance significantly alter lumen diameter and CIMT measurements made using image analysis software. When CIMT and FMD are used to test the efficacy of cardioprotective interventions, the DR, gain and probe position used to record baseline scans should be documented and replicated in post-treatment scans in individual trial subjects. If more than one sonographer or imaging centre is used to collect data, the study protocol should document specific DR and gain settings to be used in all subjects

    Carotid artery plaque in women with rheumatoid arthritis and low estimated cardiovascular disease risk: a cross-sectional study

    Get PDF
    INTRODUCTION: We previously reported that most patients with rheumatoid arthritis (RA) and moderate cardiovascular disease (CVD) risk according to the Systematic COronary Evaluation score (SCORE) experience carotid artery plaque. In this study, we aimed to identify patient characteristics that can potentially predict carotid plaque presence in women with RA and a concurrent low CVD risk according to the SCORE. METHODS: A cohort of 144 women with an evaluated low risk of CVD (SCORE value of zero) was assembled amongst 550 consecutive patients with RA that underwent CVD risk factor recording and carotid artery ultrasound. Participants had no established CVD, moderate or severe chronic kidney disease, or diabetes. We assessed carotid plaque(s) presence and its associated patient characteristics. RESULTS: Carotid artery plaque was present in 35 (24.3%) of women with RA. Age, the number of synthetic disease-modifying agents (DMARDs) and total cholesterol concentrations were independently associated with plaque in multivariable stepwise backward regression analysis (odds ratio (95% confidence interval)=1.15 (1.07 to 1.24), P49.5 years or/and total cholesterol concentration of >5.4 mmol/l, respectively, compared to only 7.8% in those (n=64; 44.4%) with age≤49.5 years or/and total cholesterol concentration of ≤5.4 mmol/l, respectively. CONCLUSIONS: Approximately one-third of women with RA who experience a low SCORE value and are aged >49.5 years or/and have a total cholesterol concentration of >5.4 mmol/l, experience high-risk atherosclerosis, which requires intensive CVD risk management

    Assessment of atherosclerotic carotid plaque volume with multidetector computed tomography angiography

    Get PDF
    Purpose The amount of atherosclerotic plaque and its components (calcifications, fibrous tissue, and lipid core) could be better predictors of acute events than the now currently used degree of stenosis. Therefore, we evaluated a dedicated software tool for volume measurements of atherosclerotic carotid plaque and its components in multidetector computed tomography angiography (MDCTA) images. Materials and Methods Data acquisition was approved by the Institutional Review Board and all patients gave written informed consent. MDCTA images of 56 carotid arteries were analyzed by three observers. Plaque volumes were assessed by manual drawing of the outer vessel contour. The luminal boundary was determined based on a Hounsfield-Unit (HU) threshold. The contribution of different components was measured by the number of voxels within defined ranges of HU-values (calcification >130 HU, fibrous tissue 60–130 HU, lipid core <60 HU). Interobserver variability (IOV) was assessed. Results Plaque volume was 1,259 ± 621 mm3. The calcified, fibrous and lipid volumes were 238 ± 252 mm3, 647 ± 277 mm3 and 376 ± 283 mm3, respectively. IOV was moderate with interclass correlation coefficients (ICC) ranging from 0.76 to 0.99 and coefficients of variation (COV) ranging from 3% to 47%. Conclusion Atherosclerotic carotid plaque volume and plaque component volumes can be assessed with MDCTA with a reasonable observer variability
    corecore