3,105 research outputs found

    Quantum metrology of spatial deformation using arrays of classical and quantum light emitters

    Get PDF
    We introduce spatial deformations to an array of light sources and study how the estimation precision of the interspacing distance d changes with the sources of light used. The quantum Fisher information (QFI) is used as the figure of merit in this work to quantify the amount of information we have on the estimation parameter. We derive the generator of translations Gˆ in d due to an arbitrary homogeneous deformation applied to the array. We show how the variance of the generator can be used to easily consider how different deformations and light sources can effect the estimation precision. The single-parameter estimation problem is applied to the array, and we report on the optimal state that maximizes the QFI for d. Contrary to what may have been expected, the higher average mode occupancies of the classical states performs better in estimating d when compared with single photon emitters (SPEs). The optimal entangled state is constructed from the eigenvectors of the generator and found to outperform all these states. We also find the existence of multiple optimal estimators for the measurement of d. Our results find applications in evaluating stresses and strains, fracture prevention in materials expressing great sensitivities to deformations, and selecting frequency distinguished quantum sources from an array of reference sources

    Geometric perspective on quantum parameter estimation

    Get PDF
    Quantum metrology holds the promise of an early practical application of quantum technologies, in which measurements of physical quantities can be made with much greater precision than what is achievable with classical technologies. In this Review, the authors collect some of the key theoretical results in quantum parameter estimation by presenting the theory for the quantum estimation of a single parameter, multiple parameters, and optical estimation using Gaussian states. The authors give an overview of results in areas of current research interest, such as Bayesian quantum estimation, noisy quantum metrology, and distributed quantum sensing. The authors address the question of how minimum measurement errors can be achieved using entanglement as well as more general quantum states. This review is presented from a geometric perspective. This has the advantage that it unifies a wide variety of estimation procedures and strategies, thus providing a more intuitive big picture of quantum parameter estimation

    Comparison of standardised versus non-standardised methods for testing the in vitro potency of oxytetracycline against mannheimia haemolytica and pasteurella multocida

    Get PDF
    The in vitro pharmacodynamics of oxytetracycline was established for six isolates of each of the calf pneumonia pathogens Mannheimia haemolytica and Pasteurella multocida. Minimum inhibitory concentration (MIC), minimum bactericidal concentration (MBC) and bacterial time-kill curves were determined in two matrices, Mueller Hinton broth (MHB) and calf serum. Geometric mean MIC ratios, serum:MHB, were 25.2:1 (M. haemolytica) and 27.4:1 (P. multocida). The degree of binding of oxytetracycline to serum protein was 52.4%. Differences between serum and broth MICs could not be accounted for by oxytetracycline binding to serum protein. In vitro time-kill data suggested a co-dependent killing action of oxytetracycline. The in vitro data indicate inhibition of the killing action of oxytetracycline by serum factor(s). The nature of the inhibition requires further study. The outcome of treatment with oxytetracycline of respiratory tract infections in calves caused by M. haemolytica and P. multocida may not be related solely to a direct killing action

    Comparison of concentration methods for quantitative detection of sewage-associated viral markers in environmental waters

    Get PDF
    Pathogenic human viruses cause over half of gastroenteritis cases associated with recreational water use worldwide. They are relatively difficult to concentrate from environmental waters due to typically low concentrations and their small size. Although rapid enumeration of viruses by quantitative PCR (qPCR) has the potential to greatly improve water quality analysis and risk assessment, the upstream steps of capturing and recovering viruses from environmental water sources along with removing PCR inhibitors from extracted nucleic acids remain formidable barriers to routine use. Here, we compared the efficiency of virus recovery for three rapid methods of concentrating two microbial source tracking (MST) viral markers human adenoviruses (HAdVs) and polyomaviruses (HPyVs) from one liter tap water and river water samples on HA membranes (90 mm in diameter). Samples were spiked with raw sewage, and viral adsorption to membranes was promoted by acidification (method A) or addition of MgCl2 (methods B and C). Viral nucleic acid was extracted directly from membranes (method A), or viruses were eluted with NaOH and concentrated by centrifugal ultrafiltration (methods B and C). No inhibition of qPCR was observed for samples processed by method A, but inhibition occurred in river samples processed by B and C. Recovery efficiencies of HAdVs and HPyVs were ∼10-fold greater for method A (31 to 78%) than for methods B and C (2.4 to 12%). Further analysis of membranes from method B revealed that the majority of viruses were not eluted from the membrane, resulting in poor recovery. The modification of the originally published method A to include a larger diameter membrane and a nucleic acid extraction kit that could accommodate the membrane resulted in a rapid virus concentration method with good recovery and lack of inhibitory compounds. The frequently used strategy of viral absorption with added cations (Mg(2+)) and elution with acid were inefficient and more prone to inhibition, and will result in underestimation of the prevalence and concentrations of HAdVs and HPyVs markers in environmental waters

    Distributions of fecal markers in wastewater from different climatic zones for human fecal pollution tracking in Australian surface waters

    Get PDF
    Recreational and potable water supplies polluted with human wastewater can pose a direct health risk to humans. Therefore, sensitive detection of human fecal pollution in environmental waters is very important to water quality authorities around the globe. Microbial source tracking (MST) utilizes human fecal markers (HFMs) to detect human wastewater pollution in environmental waters. The concentrations of these markers in raw wastewater are considered important because it is likely that a marker whose concentration is high in wastewater will be more frequently detected in polluted waters. In this study, quantitative PCR (qPCR) assays were used to determine the concentrations of fecal indicator bacteria (FIB) Escherichia coli and Enterococcus spp., HFMs Bacteroides HF183, human adenoviruses (HAdVs), and polyomaviruses (HPyVs) in raw municipal wastewater influent from various climatic zones in Australia. E. coli mean concentrations in pooled human wastewater data sets (from various climatic zones) were the highest (3.2 × 10 gene copies per ml), followed by those of HF183 (8.0 × 10 gene copies per ml) and Enterococcus spp. (3.6 × 10 gene copies per ml). HAdV and HPyV concentrations were 2 to 3 orders of magnitude lower than those of FIB and HF183. Strong positive and negative correlations were observed between the FIB and HFM concentrations within and across wastewater treatment plants (WWTPs). To identify the most sensitive marker of human fecal pollution, environmental water samples were seeded with raw human wastewater. The results from the seeding experiments indicated that Bacteroides HF183 was more sensitive for detecting human fecal pollution than HAdVs and HPyVs. Since the HF183 marker can occasionally be present in nontarget animal fecal samples, it is recommended that HF183 along with a viral marker (HAdVs or HPyVs) be used for tracking human fecal pollution in Australian environmental waters

    Vitamin B6 Deficiency and Galactose Induced Alterations in Morphology and Osmotic Fragility of Rat Erythrocytes

    Get PDF
    Recently, red blood cells have been investigated mainly for alterations in ion transporting capacity, membrane bound enzymes or modifications in the structure of its individual constituents in clinical and experimental urolithiasis. However, the implication of such modifications on the physical state or morphology of cells has not been investigated. Scanning electron microscopic studies performed in vitamin B6 deficient and/or galactose fed rat (established hyperoxaluric models) erythrocytes, showed the presence of large number of stomatocytes, spherocytes and other variously deformed cells as compared to discocytic cells seen in normal control group. These changes in shape were in concurrence with red cell osmotic fragility, which decreased both in vitamin B6 deficient and vitamin B6 deficient + galactose fed group (19% and 33% hemolysis at 4 g/l NaCl, respectively) while it increased in galactose control group (73% hemolysis at 4 g/l NaCl) as compared to normal control group (55 % hemolysis at 4 g/l NaCl). These morphological and physical state alterations could be correlated with red blood cells\u27 membrane cholesterol and phospholipid sub-class distribution. These findings suggest that some structural membrane changes occur due to vitamin B6 deficiency and/or galactose feeding, which may be responsible for the altered membrane functions known to be associated with pathogenesis of urolithiasis

    Role of contrast-enhanced ultrasound (CEUS) in paediatric practice: an EFSUMB position statement

    Get PDF
    The use of contrast-enhanced ultrasound (CEUS) in adults is well established in many different areas, with a number of current applications deemed off-label, but the use supported by clinical experience and evidence. Paediatric CEUS is also an off-label application until recently with approval specifically for assessment of focal liver lesions. Nevertheless there is mounting evidence of the usefulness of CEUS in children in many areas, primarily as an imaging technique that reduces exposure to radiation, iodinated contrast medium and the patient-friendly circumstances of ultrasonography. This position statement of the European Federation of Societies in Ultrasound and Medicine (EFSUMB) assesses the current status of CEUS applications in children and makes suggestions for further development of this technique
    • …
    corecore