5,038 research outputs found

    Branching Fractions for chi_cJ -\u3e p p-bar pi^0, p p-bar eta, and p p-bar omega

    Get PDF
    Using a sample of 25.9 million psi(2S) decays acquired with the CLEO-c detector at the CESR e^+e^- collider, we report branching fractions for the decays chi_cJ -\u3e p p-bar pi^0, p p-bar eta, and p p-bar omega, with J=0,1,2. Our results for B(chi_cJ-\u3e p p-bar pi^0) and B(chi_cJ-\u3e p p-bar eta) are consistent with, but more precise than, previous measurements. Furthermore, we include the first measurement of B(chi_cJ-\u3e p p-bar omega)

    Ground-based detection of a vibration-rotation line of HD in Orion

    Get PDF
    The v =1-0 R(5) line of HD at 2.46um has been detected at the position of brightest line emission of shocked H2 in the Orion Molecular Cloud. The flux in this HD line, when compared to that of the previously detected HD 0--0 R(5) line at 19.43um, suggests that, like the v=1 levels of H2, the v=1 levels of HD are populated in LTE, despite their much higher rates of spontaneous emission compared to H2. The higher than expected population of vibrationally excited HD may be due to chemical coupling of HD to H2 via the reactive collisions HD + H H2 + D in the shocked gas. The deuterium abundance implied by the strengths of these lines relative to those of H2 is (5.1 pm 1.9 x 10^-6.Comment: 9 pages, 2 figures, Proceedings of the Conference on "Deuterium in the Universe," to be published in Planetary and Space Science

    A User\u27s Manual for: A Clear Sky Solar Radiation Generator for the Personal Computer

    Get PDF
    Occasional Papers in Geography Publication No. 3 This program is primarily designed as an interactive instructional aid for students concerned with select aspects of shortwave radiation climatology. On the basis of user supplied temporal and geographic information the algorithm will produce instantaneous values of diffuse, direct, global, reflected, net shortwave and extraterrestrial radiation. Daily totals are also generated by numerical approximation of the area under the curve as described by each of these quantities. In addition, an optional routine to compute the instantaneous values of solar elevations and azimuths is included to further define the nature of astronomical relationships for the site under investigation. The overall structure of the program is such that the appropriate variables can be easily and conveniently manipulated to provide an accurate estimate of the shortwave radiative balance at a given point with a minimal knowledge of the relevant mathematics and of FORTRAN computer programming. It is hoped that the interested student will investigate the range of possibilities offered by this routine and use it as a stepping stone to the understanding of the many fundamental concepts involved in shortwave radiative transfer and its geographical distribution.https://pdxscholar.library.pdx.edu/geog_occasionalpaper/1001/thumbnail.jp

    The Cleo III Ring Imaging Cherenkov Detector

    Get PDF
    The CLEO detector has been upgraded to include a state of the art particle identification system, based on the Ring Imaging Cherenkov Detector (RICH) technology, in order to take data at the upgraded CESR electron positron collider. The expected performance is reviewed, as well as the preliminary results from an engineering run during the first few months of operation of the CLEO III detector.Comment: 5 pages, 2 Figures Talk given by M. Artuso at 8th Pisa Meeting on Advanced Detectors, May 200

    Unexpected Effect of Internal Degrees of Freedom on Transverse Phonons in Supercooled Liquids

    Full text link
    We show experimentally that in a supercooled liquid composed of molecules with internal degrees of freedom the internal modes contribute to the frequency dependent shear viscosity and damping of transverse phonons, which results in an additional broadening of the transverse Brillouin lines. Earlier, only the effect of internal modes on the frequency dependent bulk viscosity and damping of longitudinal phonons was observed and explained theoretically in the limit of weak coupling of internal degrees of freedom to translational motion. A new theory is needed to describe this new effect. We also demonstrate, that the contributions of structural relaxation and internal processes to the width of the Brillouin lines can be separated by measurements under high pressure

    Performance of the CLEO III LiF-TEA Ring Imaging Cherenkov Detector in a High Energy Muon Beam

    Get PDF
    The CLEO III Ring Imaging Cherenkov detector uses LiF radiators to generate Cherenkov photons which are then detected by proportional wire chambers using a mixture of CH4_4 and TEA gases. The first two photon detector modules which were constructed, were taken to Fermilab and tested in a beam dump that provided high momentum muons. We report on results using both plane and sawtooth shaped radiators. Specifically, we discuss the number of photoelectrons observed per ring and the angular resolution. The particle separation ability is shown to be sufficient for the physics of CLEO III

    Preventative tele-health supported services for early stage chronic obstructive pulmonary disease: a protocol for a pragmatic randomized controlled trial pilot

    Get PDF
    Background Chronic Obstructive Pulmonary Disease (COPD) is a prevalent debilitating long term condition. It is the second most common cause of emergency admission to hospital in the UK and remains one of the most costly conditions to treat through acute care. Tele-health monitoring offers potential to reduce the rates of re-hospitalisation and emergency department visits and improve quality of life for people with COPD. However, the current evidence base to support technology adoption and implementation is limited and the resource implications for implementing tele-health in practice can be very high. This trial will employ tele-health monitoring in a preventative capacity for patients diagnosed with early stage COPD following discharge from hospital to determine whether it reduces their need for additional health service support or hospital admission and improves their quality of life. Methods/Design We describe a pilot study for a two arm, one site randomized controlled trial (RCT) to determine the effect of tele-health monitoring on self-management, quality of life and patient satisfaction. Sixty patients who have been discharged from one acute trust with a primary diagnosis of COPD and who have agreed to receive community clinical support following discharge from acute care will be randomly assigned to one of two groups: (a) Tele-health supported Community COPD Service; or (b) Usual Care. The tele-health supported service involves the patient receiving two home visits with a specialist COPD clinician (nurse or physiotherapist) then participating in daily tele-monitoring over an eight week period. Usual care consists of six home visits to the patient by specialist COPD clinicians again over eight successive weeks. Health status and quality of life data for all participants will be measured at baseline, on discharge from the service and at six months post discharge from the service. Discussion The tele-health service under study is a complex service delivered through a collaboration between local authority and health care partners. The implementation of this service demanded significant changes to established working patterns and has been a challenging process requiring considerable planning - a challenge that many providers are likely to face in the future. Trial registration Current Controlled Trials ISRCTN6885601

    Optimum Monte Carlo Simulations: Some Exact Results

    Full text link
    We obtain exact results for the acceptance ratio and mean squared displacement in Monte Carlo simulations of the simple harmonic oscillator in DD dimensions. When the trial displacement is made uniformly in the radius, we demonstrate that the results are independent of the dimensionality of the space. We also study the dynamics of the process via a spectral analysis and we obtain an accurate description for the relaxation time.Comment: 17 pages, 8 figures. submitted to J. Phys.

    Construction, Pattern Recognition and Performance of the CLEO III LiF-TEA RICH Detector

    Get PDF
    We briefly describe the design, construction and performance of the LiF-Tea RICH detector built to identify charged particles in the CLEO III experiment. Excellent pion/kaon separation is demonstrated
    • …
    corecore