80 research outputs found
Patella Infera in an HIV Positive Patient Following Total Knee Arthroplasty
A lowering of the patella after total knee arthroplasty is accompanied by pain and a restriction of the range of motion. With its etiology being unclear at present, a multifactorial genesis is under discussion. For the first time, we present a case report describing an HIV infection as a possible cause of patella infera
Osteogenic Predifferentiation of Human Bone Marrow-Derived Stem Cells by Short-Term Mechanical Stimulation
It is commonly accepted that bone marrow-derived stem cells (BMSCs) have to be expanded in vitro, but a prolonged time in culture decreases their multilineage potential. Mechanical and biological stimuli have been used to improve their osteogenic potential. While long-term stimulation has been shown to improve osteogenic differentiation, it remains to be seen whether short-term stimulation is also sufficient
Forgivingness of an Anteromedially Positioned Small Locked Plate for High Tibial Osteotomy in Case of Overcorrection and Lateral Hinge Fracture
High tibial osteotomy (HTO) represents a sensible treatment option for patients with moderate unicondylar osteoarthritis of the knee and extraarticular malalignment. The possibility of a continuously variable correction setting and a surgical approach low in complications has meant that the medial opening osteotomy has prevailed over the past decades. The objective of the present study was to determine whether anteromedially positioned small plates are nevertheless forgiving under biomechanically unfavourable conditions (overcorrection and lateral hinge fracture). In this study, a simulated HTO was performed on composite tibiae with a 10-mm wedge and fixed-angle anteromedial osteosynthesis with a small implant. Force was applied axially in a neutral mechanical axis, a slight and a marked overcorrection into valgus, with and without a lateral hinge fracture in each case. At the same time, a physiological gait with a dual-peak force profile and a peak load of 2.4 kN was simulated. Interfragmentary motion and rigidity were determined. The rigidity of the osteosynthesis increased over the cycles investigated. A slight overcorrection into valgus led to the lowest interfragmentary motion, compared with pronounced valgisation and neutral alignment. A lateral hinge fracture led to a significant decrease in rigidity and increase in interfragmentary motion. However, in no case was the limit of 1 mm interfragmentary motion critical for osteotomy healing exceeded. The degree of correction of the leg axis, and the presence of a lateral hinge fracture, have an influence on rigidity and interfragmentary motion. From a mechanically neutral axis ranging up to pronounced overcorrection, the implant investigated offers sufficient stability to allow healing of the osteotomy, even if a lateral hinge fracture is present
Recommended from our members
FLIM data analysis based on Laguerre polynomial decomposition and machine-learning
Significance: The potential of fluorescence lifetime imaging microscopy (FLIM) is recently being recognized, especially in biological studies. However, FLIM does not directly measure the lifetimes, rather it records the fluorescence decay traces. The lifetimes and/or abundances have to be estimated from these traces during the phase of data processing. To precisely estimate these parameters is challenging and requires a well-designed computer program. Conventionally employed methods, which are based on curve fitting, are computationally expensive and limited in performance especially for highly noisy FLIM data. The graphical analysis, while free of fit, requires calibration samples for a quantitative analysis.
Aim: We propose to extract the lifetimes and abundances directly from the decay traces through machine learning (ML).
Approach: The ML-based approach was verified with simulated testing data in which the lifetimes and abundances were known exactly. Thereafter, we compared its performance with the commercial software SPCImage based on datasets measured from biological samples on a time-correlated single photon counting system. We reconstructed the decay traces using the lifetime and abundance values estimated by ML and SPCImage methods and utilized the root-mean-squared-error (RMSE) as marker.
Results: The RMSE, which represents the difference between the reconstructed and measured decay traces, was observed to be lower for ML than for SPCImage. In addition, we could demonstrate with a three-component analysis the high potential and flexibility of the ML method to deal with more than two lifetime components
Polyhexanide and hydrogen peroxide inhibit proteoglycan synthesis of human chondrocytes
The use of local antiseptics is a common method in septic joint surgery. We tested polyhexanide and hydrogen peroxide, two of the most frequently used antiseptics with high efficacy and low toxicity. The purpose of this study was to evaluate the effects of both antiseptics on the extracellular cartilaginous matrix synthesis of human chondrocytes. Chondrocytes were isolated from donated human knee joints, embedded in alginate beads, and incubated for 10 and 30 minutes with polyhexanide (0.04%), hydrogen peroxide (3%), or phosphate-buffered saline (PBS) for control. Cartilaginous matrix production was quantified through light microscopic analysis of Alcian blue staining. Cell number and morphology were detected by histological analysis. Chondrocytes showed a decreased intensity of blue colouring after antiseptic treatment versus PBS. In contrast to that, neither the cell number per view field nor the cell morphology differed between the groups. Polyhexanide has more toxic potential than hydrogen peroxide. Based on the fact that the cell number and morphology was not altered by the substances at the examined concentrations, the lower intensity of Alcian blue staining of treated chondrocytes indicates a decreased cartilage-specific matrix synthesis by polyhexanide more than by hydrogen peroxide and control
Genç tacir
İbn-i Asım Refet'in Çocuklara Rehber'de tefrika edilen Genç Tacir adlı romanıTefrika yarım kalmıştır. Arşivdeki eksikler nedeniyle tefrikanın tamamlanıp tamamlanmadığı bilinmemektedir
CTLA-4 mediates inhibitory function of mesenchymal stem/stromal cells
Mesenchymal stem/stromal cells (MSCs) are stem cells of the connective tissue, possess a plastic phenotype, and are able to differentiate into various tissues. Besides their role in tissue regeneration, MSCs perform additional functions as a modulator or inhibitor of immune responses. Due to their pleiotropic function, MSCs have also gained therapeutic importance for the treatment of autoimmune diseases and for improving fracture healing and cartilage regeneration. However, the therapeutic/immunomodulatory mode of action of MSCs is largely unknown. Here, we describe that MSCs express the inhibitory receptor CTLA-4 (cytotoxic T lymphocyte antigen 4). We show that depending on the environmental conditions, MSCs express different isoforms of CTLA-4 with the secreted isoform (sCTLA-4) being the most abundant under hypoxic conditions. Furthermore, we demonstrate that the immunosuppressive function of MSCs is mediated mainly by the secretion of CTLA-4. These findings open new ways for treatment when tissue regeneration/fracture healing is difficult
- …