315 research outputs found

    Lateral Diffusion Length Changes in HgCdTe Detectors in a Proton Environment

    Get PDF
    This paper presents a study of the performance degradation in a proton environment of very long wavelength infrared (VLWIR) HgCdTe detectors. The energy dependence of the Non-Ionizing Energy Loss (NIEL) in HgCdTe provides a framework for estimating the responsivity degradation in VLWIR HgCdTe due to on orbit exposure from protons. Banded detector arrays that have different detector designs were irradiated at proton energies of 7, 12, and 63 MeV. These banded detector arrays allo~vedin sight into how the fundamental detector parameters degraded in a proton environment at the three different proton energies. Measured data demonstrated that the detector responsivity degradation at 7 MeV is 5 times larger than the degradation at 63 MeV. The comparison of the responsivity degradation at the different proton energies suggests that the atomic Columbic interaction of the protons with the HgCdTe detector is likely the primary mechanism responsible for the degradation in responsivity at proton energies below 30 MeV

    Text messaging and brief phone calls for weight loss in overweight and obese English- and Spanish-speaking adults: A 1-year, parallel-group, randomized controlled trial.

    Get PDF
    BACKGROUND:Weight loss interventions based solely on text messaging (short message service [SMS]) have been shown to be modestly effective for short periods of time and in some populations, but limited evidence is available for positive longer-term outcomes and for efficacy in Hispanic populations. Also, little is known about the comparative efficacy of weight loss interventions that use SMS coupled with brief, technology-mediated contact with health coaches, an important issue when considering the scalability and cost of interventions. We examined the efficacy of a 1-year intervention designed to reduce weight among overweight and obese English- and Spanish-speaking adults via SMS alone (ConTxt) or in combination with brief, monthly health-coaching calls. ConTxt offered 2-4 SMS/day that were personalized, tailored, and interactive. Content was theory- and evidence-based and focused on reducing energy intake and increasing energy expenditure. Monthly health-coaching calls (5-10 minutes' duration) focused on goal-setting, identifying barriers to achieving goals, and self-monitoring. METHODS AND FINDINGS:English- and Spanish-speaking adults were recruited from October 2011 to March 2013. A total of 298 overweight (body mass index [BMI] 27.0 to 39.9 kg/m2) adults (aged 21-60 years; 77% female; 41% Hispanic; 21% primarily Spanish speaking; 44% college graduates or higher; 22% unemployed) were randomly assigned (1:1) to receive either ConTxt only (n = 101), ConTxt plus health-coaching calls (n = 96), or standard print materials on weight reduction (control group, n = 101). We used computer-based permuted-block randomization with block sizes of three or six, stratified by sex and Spanish-speaking status. Participants, study staff, and investigators were masked until the intervention was assigned. The primary outcome was objectively measured percent of weight loss from baseline at 12 months. Differences between groups were evaluated using linear mixed-effects regression within an intention-to-treat framework. A total of 261 (87.2%) and 253 (84.9%) participants completed 6- and 12-month visits, respectively. Loss to follow-up did not differ by study group. Mean (95% confidence intervals [CIs]) percent weight loss at 12 months was -0.61 (-1.99 to 0.77) in the control group, -1.68 (-3.08 to -0.27) in ConTxt only, and -3.63 (-5.05 to -2.81) in ConTxt plus health-coaching calls. At 12 months, mean (95% CI) percent weight loss, adjusted for baseline BMI, was significantly different between ConTxt plus health-coaching calls and the control group (-3.0 [-4.99 to -1.04], p = 0.003) but not between the ConTxt-only and the control group (-1.07 [-3.05 to 0.92], p = 0.291). Differences between ConTxt plus health-coaching calls and ConTxt only were not significant (-1.95 [-3.96 to 0.06], p = 0.057). These findings were consistent across other weight-related secondary outcomes, including changes in absolute weight, BMI, and percent body fat at 12 months. Exploratory subgroup analyses suggested that Spanish speakers responded more favorably to ConTxt plus health-coaching calls than English speakers (Spanish contrast: -7.90 [-11.94 to -3.86], p < 0.001; English contrast: -1.82 [-4.03 to 0.39], p = 0.107). Limitations include the unblinded delivery of the intervention and recruitment of a predominantly female sample from a single site. CONCLUSIONS:A 1-year intervention that delivered theory- and evidence-based weight loss content via daily personalized, tailored, and interactive SMS was most effective when combined with brief, monthly phone calls. TRIAL REGISTRATION:ClinicalTrials.gov NCT01171586

    A Comparison of High-Energy Electron and Cobalt-60 Gamma-Ray Radiation Testing

    Get PDF
    In this paper, a comparison between the effects of irradiating microelectronics with high energy electrons and Cobalt-60 gamma-rays is examined. Additionally, the effect of electron energy is also discussed. A variety of part types are investigated, including discrete bipolar transistors, hybrids, and junction field effect transistor

    Therapeutic targeting of integrin Ī±vĪ²6 in breast cancer

    Get PDF
    BACKGROUND: Integrin ?v?6 promotes migration, invasion, and survival of cancer cells; however, the relevance and role of ?v?6 has yet to be elucidated in breast cancer.METHODS: Protein expression of integrin subunit beta6 (?6) was measured in breast cancers by immunohistochemistry (n &gt; 2000) and ITGB6 mRNA expression measured in the Molecular Taxonomy of Breast Cancer International Consortium dataset. Overall survival was assessed using Kaplan Meier curves, and bioinformatics statistical analyses were performed (Cox proportional hazards model, Wald test, and Chi-square test of association). Using antibody (264RAD) blockade and siRNA knockdown of ?6 in breast cell lines, the role of ?v?6 in Human Epidermal Growth Factor Receptor 2 (HER2) biology (expression, proliferation, invasion, growth in vivo) was assessed by flow cytometry, MTT, Transwell invasion, proximity ligation assay, and xenografts (n ? 3), respectively. A student's t-test was used for two variables; three-plus variables used one-way analysis of variance with Bonferroni's Multiple Comparison Test. Xenograft growth was analyzed using linear mixed model analysis, followed by Wald testing and survival, analyzed using the Log-Rank test. All statistical tests were two sided.RESULTS: High expression of either the mRNA or protein for the integrin subunit ?6 was associated with very poor survival (HR = 1.60, 95% CI = 1.19 to 2.15, P = .002) and increased metastases to distant sites. Co-expression of ?6 and HER2 was associated with worse prognosis (HR = 1.97, 95% CI = 1.16 to 3.35, P = .01). Monotherapy with 264RAD or trastuzumab slowed growth of MCF-7/HER2-18 and BT-474 xenografts similarly (P &lt; .001), but combining 264RAD with trastuzumab effectively stopped tumor growth, even in trastuzumab-resistant MCF-7/HER2-18 xenografts.CONCLUSIONS: Targeting ?v?6 with 264RAD alone or in combination with trastuzumab may provide a novel therapy for treating high-risk and trastuzumab-resistant breast cancer patients.<br/

    Detectors for the James Webb Space Telescope Near-Infrared Spectrograph I: Readout Mode, Noise Model, and Calibration Considerations

    Full text link
    We describe how the James Webb Space Telescope (JWST) Near-Infrared Spectrograph's (NIRSpec's) detectors will be read out, and present a model of how noise scales with the number of multiple non-destructive reads sampling-up-the-ramp. We believe that this noise model, which is validated using real and simulated test data, is applicable to most astronomical near-infrared instruments. We describe some non-ideal behaviors that have been observed in engineering grade NIRSpec detectors, and demonstrate that they are unlikely to affect NIRSpec sensitivity, operations, or calibration. These include a HAWAII-2RG reset anomaly and random telegraph noise (RTN). Using real test data, we show that the reset anomaly is: (1) very nearly noiseless and (2) can be easily calibrated out. Likewise, we show that large-amplitude RTN affects only a small and fixed population of pixels. It can therefore be tracked using standard pixel operability maps.Comment: 55 pages, 10 figure

    Recent Total Ionizing Dose and Displacement Damage Compendium of Candidate Electronics for NASA Space Systems

    Get PDF
    Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices

    Recent Results on SEU Hardening of SiGe HBT Logic Circuits

    Get PDF
    A viewgraph presentation on SEU tolerant SiGe HBT technology is shown. The topics include: 1) Introduction; 2) TID and SEU in SiGe Technology; 3) RHBD Techniques; 4) Experiment; 5) Heavy-Ion Data and Analysis; and 6) Summary
    • ā€¦
    corecore