423 research outputs found
Beam test results of 3D fine-grained scintillator detector prototype for a T2K ND280 neutrino active target
An upgrade of the long baseline neutrino experiment T2K near detector ND280
is currently being developed with the goal to reduce systematic uncertainties
in the prediction of number of events at the far detector Super-Kamiokande. The
upgrade program includes the design and construction of a new highly granular
fully active scintillator detector with 3D WLS fiber readout as a neutrino
target. The detector of about in size and a mass
of 2.2~tons will be assembled from about plastic
scintillator cubes of . Each cube is read out by three
orthogonal Kuraray Y11 Wave Length Shifting (WLS) fibers threaded through the
detector. A detector prototype made of 125 cubes was assembled and tested in a
charged particle test beam at CERN in the fall of 2017. This paper presents the
results obtained on the light yield and timing as well as on the optical
cross-talk between the cubes.Comment: 5 pages, 8 figure
A new limit of T-violating transverse muon polarization in the decay
A search for T-violating transverse muon polarization () in the
decay was performed using kaon decays at rest. A
new improved value, , was
obtained giving an upper limit, . The T-violation parameter
was determined to be Im giving
an upper limit, Im.Comment: 5 pages, 4 figure
Test of exotic scalar and tensor interactions in K_e3 decay using stopped positive kaons
The form factors of the decay K+ --> pi0 e+ nu (K_e3) have been determined
from the comparison of the experimental and Monte Carlo Dalitz distributions
containing about 10^5 K_e3 events. The following values of the parameters were
obtained: lambda_+ = 0.0278 +- 0.0017(stat) +- 0.0015(syst), f_S/f_+(0) =
0.0040 +- 0.0160(stat) +- 0.0067(syst) and f_T/f_+(0) = 0.019 +- 0.080(stat) +-
0.038(syst). Both scalar f_S and tensor f_T form factors are consistent with
the Standard Model predictions of zero values.Comment: 10 pages, 5 figures, contributed to the proceedings of NANP
Conference, Dubna, June 19-23, 200
Scintillator counters with WLS fiber/MPPC readout for the side muon range detector (SMRD)of the T2K experiment
The T2K neutrino experiment at J-PARC uses a set of near detectors to measure
the properties of an unoscillated neutrino beam and neutrino interaction
cross-sections. One of the sub-detectors of the near-detector complex, the side
muon range detector (SMRD), is described in the paper. The detector is designed
to help measure the neutrino energy spectrum, to identify background and to
calibrate the other detectors. The active elements of the SMRD consist of 0.7
cm thick extruded scintillator slabs inserted into air gaps of the UA1 magnet
yokes. The readout of each scintillator slab is provided through a single WLS
fiber embedded into a serpentine shaped groove. Two Hamamatsu multi-pixel
avalanche photodiodes (MPPC's) are coupled to both ends of the WLS fiber. This
design allows us to achieve a high MIP detection efficiency of greater than
99%. A light yield of 25-50 p.e./MIP, a time resolution of about 1 ns and a
spatial resolution along the slab better than 10 cm were obtained for the SMRD
counters.Comment: 7 pages, 4 figures; talk at TIPP09, March 12-17, Tsukuba, Japan; to
be published in the conference proceeding
Scintillator counters with multi-pixel avalanche photodiode readout for the ND280 detector of the T2K experiment
The Tokai-to-Kamioka (T2K) experiment is a second generation long baseline neutrino oscillation experiment which aims at a sensitive search for νe appearance. The main design features of the T2K near neutrino detectors located at 280 m from the target are presented, and the scintillator counters are described. The counters are readout via WLS fibers embedded into S-shaped grooves in the scintillator from both ends by multi-pixel avalanche photodiodes operating in a limited Geiger mode. Operating principles and results of tests of photosensors with a sensitive area of 1 mm2 are presented. A time resolution of 1.75 ns, a spatial resolution of 9.9 - 12.4 cm, and a detection efficiency for minimum ionizing particles of more than 99% were obtained for scintillator detectors in a beam test. © 2007 Elsevier B.V. All rights reserved
- …