91 research outputs found

    Imaging Modalities Employed in Diabetic Retinopathy Screening: A Review and Meta-Analysis

    Get PDF
    Introduction: Urbanization has caused dramatic changes in lifestyle, and these rapid transitions have led to an increased risk of noncommunicable diseases, such as type 2 diabetes. In terms of cost-effectiveness, screening for diabetic retinopathy is a critical aspect in diabetes management. The aim of this study was to review the imaging modalities employed for retinal examination in diabetic retinopathy screening. Methods: The PubMed and Web of Science databases were the main sources used to investigate the medical literature. An extensive search was performed to identify relevant articles concerning “imaging”, “diabetic retinopathy” and “screening” up to 1 June 2021. Imaging techniques were divided into the following: (i) mydriatic fundus photography, (ii) non-mydriatic fundus photography, (iii) smartphone-based imaging, and (iv) ultrawide-field imaging. A meta-analysis was performed to analyze the performance and technical failure rate of each method. Results: The technical failure rates for mydriatic and non-mydriatic digital fundus photography, smartphone-based and ultrawide-field imaging were 3.4% (95% CI: 2.3–4.6%), 12.1% (95% CI: 5.4–18.7%), 5.3% (95% CI: 1.5–9.0%) and 2.2% (95% CI: 0.3–4.0%), respectively. The rate was significantly different between all analyzed techniques (p < 0.001), and the overall failure rate was 6.6% (4.9–8.3%; I2 = 97.2%). The publication bias factor for smartphone-based imaging was significantly higher than for mydriatic digital fundus photography and non-mydriatic digital fundus photography (b = −8.61, b = −2.59 and b = −7.03, respectively; p < 0.001). Ultrawide-field imaging studies were excluded from the final sensitivity/specificity analysis, as the total number of patients included was too small. Conclusions: Regardless of the type of the device used, retinal photographs should be taken on eyes with dilated pupils, unless contraindicated, as this setting decreases the rate of ungradable images. Smartphone-based and ultrawide-field imaging may become potential alternative methods for optimized DR screening; however, there is not yet enough evidence for these techniques to displace mydriatic fundus photography

    Imaging Modalities Employed in Diabetic Retinopathy Screening: A Review and Meta-Analysis

    Get PDF
    Introduction: Urbanization has caused dramatic changes in lifestyle, and these rapid transitions have led to an increased risk of noncommunicable diseases, such as type 2 diabetes. In terms of cost-effectiveness, screening for diabetic retinopathy is a critical aspect in diabetes management. The aim of this study was to review the imaging modalities employed for retinal examination in diabetic retinopathy screening. Methods: The PubMed and Web of Science databases were the main sources used to investigate the medical literature. An extensive search was performed to identify relevant articles concerning “imaging”, “diabetic retinopathy” and “screening” up to 1 June 2021. Imaging techniques were divided into the following: (i) mydriatic fundus photography, (ii) non-mydriatic fundus photography, (iii) smartphone-based imaging, and (iv) ultrawide-field imaging. A meta-analysis was performed to analyze the performance and technical failure rate of each method. Results: The technical failure rates for mydriatic and non-mydriatic digital fundus photography, smartphone-based and ultrawide-field imaging were 3.4% (95% CI: 2.3–4.6%), 12.1% (95% CI: 5.4–18.7%), 5.3% (95% CI: 1.5–9.0%) and 2.2% (95% CI: 0.3–4.0%), respectively. The rate was significantly different between all analyzed techniques (p < 0.001), and the overall failure rate was 6.6% (4.9–8.3%; I2 = 97.2%). The publication bias factor for smartphone-based imaging was significantly higher than for mydriatic digital fundus photography and non-mydriatic digital fundus photography (b = −8.61, b = −2.59 and b = −7.03, respectively; p < 0.001). Ultrawide-field imaging studies were excluded from the final sensitivity/specificity analysis, as the total number of patients included was too small. Conclusions: Regardless of the type of the device used, retinal photographs should be taken on eyes with dilated pupils, unless contraindicated, as this setting decreases the rate of ungradable images. Smartphone-based and ultrawide-field imaging may become potential alternative methods for optimized DR screening; however, there is not yet enough evidence for these techniques to displace mydriatic fundus photography

    Semi‐Automated Quantification of Retinal and Choroidal Biomarkers in Retinal Vascular Diseases: Agreement of Spectral‐Domain Optical Coherence Tomography with and without Enhanced Depth Imaging Mode

    Get PDF
    Background: We compared with and without enhanced depth imaging mode (EDI) in semi-automated quantification of retinal and choroidal biomarkers in optical coherence tomography (OCT) in patients with diabetic retinopathy (DR) or retinal vein occlusion (RVO) complicated by macular edema. We chose to study three OCT biomarkers: the numbers of hyperreflective foci (HF), the ellipsoid zone reflectivity ratio (EZR) and the choroidal vascularity index (CVI), all known to be correlated with visual acuity changes or treatment outcomes. Methods: In a single examination, one eye of each patient (n = 60; diabetic retinopathy: n = 27, retinal vein occlusion: n = 33) underwent macular 870 nm spectral domain-OCT (SD-OCT) B-scans without and with EDI mode. Semi-automated quantification of HF, EZR and CVI was applied according to preexisting published protocols. Paired Student’s t-test or Wilcoxon rank-sum test was used to test for differences in subgroups. Intraclass correlation coefficient (ICC) and Bland–Altman plots were applied to describe the agreement between quantification in EDI and conventional OCT mode. The effect of macular edema on semi-automated quantification was evaluated. Results: For the entire cohort, quantification of all three biomarkers was not significantly different in SD-OCT scans with and without EDI mode (p > 0.05). ICC was 0.78, 0.90 and 0.80 for HF, EZR and CVI. The presence of macular edema led to significant differences in the quantification of hyperreflective foci (without EDI: 80.00 ± 33.70, with EDI: 92.08 ± 38.11; mean difference: 12.09, p = 0.03), but not in the quantification of EZR and CVI (p > 0.05). Conclusion: Quantification of EZR and CVI was comparable whether or not EDI mode was used. In conclusion, both retinal and choroidal biomarkers can be quantified from one single 870 nm SD-OCT EDI image

    Comparison Study of the Two Biometers Based on Swept-Source Optical Coherence Tomography Technology

    Get PDF
    This research aimed to investigate the potential differences in the parameters, including axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), flat keratometry (Kf), steep keratometry (Ks), mean keratometry (Km), astigmatism, white-to-white (WTW) distance, acquired rate, and intraocular lens (TOL) power, between the two swept-source optical coherence tomography (SS-OCT) biometers, the ANTERION (biometer A) and IOLMaster 700 (biometer B). In a prospective observational comparative case series study, we enrolled 198 eyes undergoing cataract surgery. The AL, CCT, ACD, LT, Kf, Ks, Km, astigmatism, WTW, acquired rate, and IOL power were assessed. McNemar tests compared the acquired rate, and the paired sample t-test compared the quantitative measurement results between the groups. Nineteen eyes were excluded owing to missing AL data for either biometer. Finally, data from 179 eyes were analyzed. Between the two devices, no significant difference was found in AL, astigmatism magnitude, J0, and J45, while significant differences existed in CCT, ACD, LT, Kf, Ks, Km, WTW, astigmatism axis, and IOL power; no statistical significance was found in the AL acquired rate (biometer A, 90.9% and biometer B, 93.9%). Approximately 65.4% of eyes demonstrated >= 0.5-D difference in IOL power between the two biometers. In conclusion, the two biometers showed significant differences in all measurements (CCT, ACD, LT, K, WTW, astigmatism axis, and IOL power), except for AL.Peer reviewe

    Investigation on Non-Segmentation Based Algorithms for Microvasculature Quantification in OCTA Images

    Get PDF
    Optical Coherence Tomography Angiography (OCTA) is an imaging modality that provides three-dimensional information of the retinal microvasculature and therefore promises early diagnosis and sufficient monitoring in ophthalmology. However, there is considerable variability between experts analysing this data. Measures for quantitative assessment of the vasculature need to be developed and established, such as fractal dimension. Fractal dimension can be used to assess the complexity of vessels and has been shown to be independently associated with neovascularization, a symptom of diseases such as diabetic retinopathy. This investigation assessed the performance of three fractal dimension algorithms: Box Counting Dimension (BCD), Information Dimension (ID), and Differential Box Counting (DBC). Two of those, BCD and ID, rely on previous vessel segmentation. Assessment of the added value or disturbance regarding the segmentation step is a second aim of this study. The investigation was performed on a data set composed of 9 in vivo human eyes. Since there is no ground truth available, the performance of the methods in differentiating the Superficial Vascular Complex (SVC) and Deep Vascular Complex (DVC) layers apart and the consistency of measurements of the same layer at different time-points were tested. The performance parameters were the ICC and the Mann-Whitney U tests. The three applied methods were suitable to tell the different layers apart and showed consistent values applied in the same slab. Within the consistency test, the non-segmentation-based method, DBC, was found to be less accurate, expressed in a lower ICC value, compared to its segmentation-based counterparts. This result is thought to be due to the DBC’s higher sensitivity when compared to the other methods. This higher sensitivity might help detect changes in the microvasculature, like neovascularization, but is also more likely prone to noise and artefacts

    Comparison of Mean Corneal Power of Annular Rings and Zones Using Swept-Source Optical Coherence Tomography

    Get PDF
    This study aims to investigate differences in the mean corneal power of annular zones (corneal power measured over the inner annular zone of difference diameters) and rings (corneal power measured over a ring of different diameters) centered on the corneal apex using the swept-source optical coherence tomography technique. The mean anterior axial curvature (AAC), posterior axial curvature (PAC), and total corneal power (TCP) centered on the corneal apex with the annular rings (0-2 mm, 2-4 mm, 4-6 mm, and 6-8 mm) and zones were assessed using the ANTERION device. The paired-sample t-test was used for data comparison. For the 0-2 mm comparison, the AAC, PAC, and TCP values of rings and zones were interchangeable. For the 2-4 mm comparison, the AAC of the rings was lower than that of the zones (p = 0.004), and the TCP values of the rings were higher than that of the zones (p < 0.001). For the 4-6 mm comparison, the AAC of the rings was lower than that of the zones (p < 0.001), and the PAC and TCP values of the rings were higher than that of the zones (both p < 0.001). For the 6-8 mm comparison, the AAC of the rings was lower than that of the zones (p < 0.001), and the PAC and TCP values of the rings were higher than that of the zones (both p < 0.001). Comparisons between AAC and TCP in each sub-region showed significant differences both in the rings (p < 0.001) and the zones (p < 0.008). Differences in the AAC, PAC, and TCP measured at different diameters (2-4 mm, 4-6 mm, and 6-8 mm) of the rings and zones, centered on the corneal apex, should be noticed in clinical practice. As the diameter increases, the difference between the rings and the zones in terms of AAC, PAC, and TCP increase as well. Clinicians should also pay attention to differences between AAC and TCP for the rings and the zones within the same annular region.Peer reviewe

    Microbial keratitis-induced endophthalmitis: incidence, symptoms, therapy, visual prognosis and outcomes

    Get PDF
    Background: To evaluate symptoms, therapies and outcomes in rare microbial keratitis-induced endophthalmitis. Methods: Retrospective study with 11 patients treated between 2009 and 2014. Clinical findings, corneal diseases, history of steroids and trauma, use of contact lenses, number and type of surgical interventions, determination of causative organisms and visual acuity (VA) were evaluated. Results: The incidence of transformation from microbial keratitis to an endophthalmitis was 0.29% (n = 11/3773). In 90.9% (n = 10/11), there were pre-existent eyelid and corneal problems, in 45.5% (n = 5/11) rubeosis iridis with increased intraocular pressure and corneal decompensation, and in 18.2% (n = 2/11), ocular trauma. Specimens could be obtained in 10 of 11 samples: 33.3% of those 10 specimens were Gram-positive coagulase-negative Staphylococci (n = 3/10) or Gram-negative rods (n = 3/10) and 10.0% Staphylococcus aureus (n = 1/10). In 30% (n = 3/10), no pathogens were identifiable. 72.7% (n = 8/11) of all keratitis-induced endophthalmitis were treated with vitrectomy and 9.1% (n = 1/11) with amniotic-membrane transplantation. In 27.3% (n = 3/11) the infected eye had to be enucleated – 18.2% (n = 2/11) primarily, 9.1% (n = 1/11) secondarily. No patient suffered from sympathetic ophthalmia. The median initial VA was 2.1 logMAR (n = 11/11). At one month, median VA was 2.0 logMAR (n = 7/11), after three months 2.0 logMAR (n = 6/11), and after one year 2.05 logMAR (n = 6/11). The change in VA was not significant (p &gt; 0.99). 36.4% (n = 4/11) of the cases resulted in blindness. Conclusions: The overall outcome is poor. Enucleation should be weighed against the risk of local and systemic spread of the infection, prolonged rehabilitation and sympathetic ophthalmia

    Incidence and Risk Factors for Berger's Space Development after Uneventful Cataract Surgery : Evidence from Swept-Source Optical Coherence Tomography

    Get PDF
    Background: This study investigates the incidence and risk factors for the development of Berger's space (BS) after uneventful phacoemulsification based on swept-source optical coherence tomography (SS-OCT). Methods: Cataractous eyes captured using qualified SS-OCT images before and after uneventful phacoemulsification cataract surgery were included. Six high-resolution cross-sectional anterior segment SS-OCT images at 30 degrees intervals were used for BS data measurements. BS width was measured at three points on each scanned meridian line: the central point line aligned with the cornea vertex and two point lines at the pupil's margins. Results: A total of 223 eyes that underwent uneventful cataract surgery were evaluated. Preoperatively, only two eyes (2/223, 0.9%) were observed to have consistent BS in all six scanning directions. BS was observed postoperatively in 44 eyes (44/223, 19.7%). A total of 13 eyes (13/223, 5.8%) with insufficient image quality, pupil dilation, or lack of preoperative image data were excluded from the study. A total of 31 postoperative eyes with BS and 31 matched eyes without BS were included in the final data analysis. The smallest postoperative BS width was in the upper quadrant of the vertical meridian line (90 degrees), with a mean value of 280 mu m. The largest BS width was observed in the opposite area of the main clear corneal incision, with a mean value >500 mu m. Conclusions: Uneven-width BS is observable after uneventful phacoemulsification. Locations with a much wider BS (indirect manifestation of Wieger zonular detachment) are predominantly located in the opposite direction to the main corneal incisions.Peer reviewe

    Automated vessel centerline extraction and diameter measurement in OCT Angiography

    Get PDF
    Optical Coherence Tomography Angiography (OCTA) is a non-invasive imaging technique that enables the visualizationof perfused vasculature in vivo. In ophthalmology,it allows the physician to monitor diseases affecting the vascular networks of the retina such as age-related macular degeneration or diabetic retinopathy. Due to the complexity of the vasculature in the retina,it is of interest to automatically extract vascular parameters which describe the condition of the vessels. Suitable parameters could improve the diagnosis and the treatment during the course of therapy.We present an automated algorithm tocompute the diameters of the vessels in en face OCTA images. After segmentingthe images, the vessel centerlinewascomputed using a thinningalgorithm.The centerline wasrefined by detecting invalid pixelssuch as spursandbycontinuing the centerline until the endsof the vessels. Lastly, the diameter wascomputed by dilating a discrete circle at the position of the centerline or by measuring the distance between both borders of the vessels. The developed algorithms were applied to in vivo images of human eyes. Certainly, no ground truth was available. Hence, a plausibility check was performed by comparing the measured diameters of two different layers of the retina (Superficial Vascular Complex (SVC) and Deep Vascular Complex (DVC)). Each layer exhibits a different characteristic vasculature.The algorithm clearly reflectedthe differences from both retinal layers. The measured diameters demonstrate that the DVC consists of more capillaries and considerably smaller vessels compared to the SVC.The presented method enables automated analysis of the retinal vasculature and forms thereby the basis for monitoringdiseases influencing the vasculature of the retina. The validation of the method using an artificial ground truth is still neede

    Optical and material analysis of opacified hydrophilic intraocular lenses after explantation: a laboratory study

    Get PDF
    Background: The opacification of hydrophilic intraocular lenses (IOLs) is a very rare complication in terms of absolute numbers. We report on the analyses of opacified Euromaxx ALI313Y and ALI313 IOLs (Argonoptics, Germany) using light and scanning electron microscopy, X-ray spectroscopy and optical bench analysis. Methods: Opacified Euromaxx ALI313Y and ALI313 IOLs were explanted after patients presented with a decrease in visual acuity. The explants were sent to our laboratory and examined using light and scanning electron microscopy. The composition of the deposits was analysed using X-ray spectroscopy. The optical quality of the intraocular lens (IOL) was assessed using the OptiSpheric IOL PRO optical bench (Trioptics GmbH Wedel, Germany). Modulation transfer function (MTF) was measured at all spatial frequencies and United States Air Force (USAF) 1951 resolution target pictures were documented. Results: Macroscopically, the entire optic was opacified in all IOLs. Light and scanning electron microscopy revealed numerous fine, granular, crystalline-like deposits, which were always distributed in a line parallel to the anterior and posterior surfaces of the IOLs. X-ray spectroscopy could prove the deposits consisted of Calcium and Phosphate. Measurements in the optical bench showed deterioration of MTF values at all spatial frequencies and the USAF target pictures demonstrated a significant reduction of brightness as well as resolution with the opacified IOLs. Conclusions: The calcification of hydrophilic IOLs only occurs rarely. The exact chemical composition of the deposits can be assessed by means of X-ray spectroscopy. Optical quality analysis of the explanted Euromaxx ALI313Y and ALI313 IOLs showed significant reduction of MTF values, which was confirmed by USAF target pictures