28 research outputs found

    Thermal generation of spin current in epitaxial CoFe2O4 thin films

    Full text link
    The longitudinal spin Seebeck effect (LSSE) has been investigated in high-quality epitaxial CoFe2O4 (CFO) thin films. The thermally excited spin currents in the CFO films are electrically detected in adjacent Pt layers due to the inverse spin Hall effect (ISHE). The LSSE signal exhibits a linear increase with increasing temperature gradient, yielding a LSSE coefficient of ~100 nV/K at room temperature. The temperature dependence of the LSSE is investigated from room temperature down to 30 K, showing a significant reduction at low temperatures, revealing that the total amount of thermally generated magnons decreases. Furthermore, we demonstrate that the spin Seebeck effect is an effective tool to study the magnetic anisotropy induced by epitaxial strain, especially in ultrathin films with low magnetic moments.Comment: 17 pages, 4 figure

    Magnetic field control of the spin Seebeck effect

    Full text link
    The origin of the suppression of the longitudinal spin Seebeck effect by applied magnetic fields is studied. We perform numerical simulations of the stochastic Landau-Lifshitz-Gilbert equation of motion for an atomistic spin model and calculate the magnon accumulation in linear temperature gradients for different strengths of applied magnetic fields and different length scales of the temperature gradient. We observe a decrease of the magnon accumulation with increasing magnetic field and we reveal that the origin of this effect is a field dependent change of the frequency distribution of the propagating magnons. With increasing field the magnonic spin currents are reduced due to a suppression of parts of the frequency spectrum. By comparison with measurements of the magnetic field dependent longitudinal spin Seebeck effect in YIG thin films with various thicknesses, we find that our model describes the experimental data very well, demonstrating the importance of this effect for experimental systems

    Influence of thickness and interface on the low-temperature enhancement of the spin Seebeck effect in YIG films

    Get PDF
    The temperature dependent longitudinal spin Seebeck effect (LSSE) in heavy metal (HM)/Y3Fe5O12 (YIG) hybrid structures is investigated as a function of YIG film thickness, magnetic field strength, and different HM detection material. The LSSE signal shows a large enhancement with reducing the temperature, leading to a pronounced peak at low temperatures. We find the LSSE peak temperature strongly depends on the film thickness as well as on the magnetic field. Our result can be well explained in the framework of magnon-driven LSSE by taking into account the temperature dependent effective propagation length of thermally excited magnons in bulk. We further demonstrate that the LSSE peak is significantly shifted by changing the interface coupling to an adjacent detection layer, revealing a more complex behavior beyond the currently discussed bulk effect. By direct microscopic imaging of the interface, we correlate the observed temperature dependence with the interface structure between the YIG and the adjacent metal layer. Our results highlight the role of interface effects on the temperature dependent LSSE in HM/YIG system, suggesting that the temperature dependent spin current transparency strikingly relies on the interface conditions

    Magnon mode selective spin transport in compensated ferrimagnets

    Full text link
    We investigate the generation of magnonic thermal spin currents and their mode selective spin transport across interfaces in insulating, compensated ferrimagnet/normal metal bilayer systems. The spin Seebeck effect signal exhibits a non-monotonic temperature dependence with two sign changes of the detected voltage signals. Using different ferrimagnetic garnets, we demonstrate the universality of the observed complex temperature dependence of the spin Seebeck effect. To understand its origin, we systematically vary the interface between the ferrimagnetic garnet and the metallic layer, and by using different metal layers we establish that interface effects play a dominating role. They do not only modify the magnitude of the spin Seebeck effect signal but in particular also alter its temperature dependence. By varying the temperature, we can select the dominating magnon mode and we analyze our results to reveal the mode selective interface transmission probabilities for different magnon modes and interfaces. The comparison of selected systems reveals semi-quantitative details of the interfacial coupling depending on the materials involved, supported by the obtained field dependence of the signal

    Strain effects on magnetic compensation and spin reorientation transition of Co/Gd synthetic ferrimagnets

    Get PDF
    Synthetic ferrimagnets are an attractive materials class for spintronics as they provide access to all-optical switching of magnetization and, at the same time, allow for ultrafast domain wall motion at angular momentum compensation. In this work, we systematically study the effects of strain on the perpendicular magnetic anisotropy and magnetization compensation of Co/Gd and Co/Gd/Co/Gd synthetic ferrimagnets. Firstly, the spin reorientation transition of a bilayer system is investigated in wedge type samples, where we report an increase in the perpendicular magnetic anisotropy in the presence of in-plane strain. Using a model for magnetostatics and spin reorientation transition in this type of system, we confirm that the observed changes in anisotropy field are mainly due to the Co magnetoelastic anisotropy. Secondly, the magnetization compensation of a quadlayer is studied. We find that magnetization compensation of this synthetic ferrimagnetic system is not altered by external strain. This confirms the resilience of this material system against strain that may be induced during the integration process, making Co/Gd ferrimagnets suitable candidates for spintronics applications.Synthetic ferrimagnets are an attractive materials class for spintronics as they provide access to all-optical switching of magnetization and, at the same time, allow for ultrafast domain wall motion at angular momentum compensation. In this work, we systematically study the effects of strain on the perpendicular magnetic anisotropy and magnetizationcompensation of Co/Gd and Co/Gd/Co/Gd synthetic ferrimagnets. Firstly, the spin reorientation transition of a bilayer system is investigated in wedge type samples, where we report an increase in the perpendicular magnetic anisotropy in the presence of in-plane strain. Using a model for magnetostatics and spin reorientation transition in this type ofsystem, we confirm that the observed changes in anisotropy field are mainly due to the Co magnetoelastic anisotropy. Secondly, the magnetization compensation of a quadlayer is studied. We find that magnetization compensation of this synthetic ferrimagnetic system is not altered by external strain. This confirms the resilience of this material systemagainst strain that may be induced during the integration process, making Co/Gd ferrimagnets suitable candidates for spintronics applications

    Electric field modification of magnetotransport in Ni thin films on (011) PMN-PT piezosubstrates

    Get PDF
    This study reports the magnetotransport and magnetic properties of 20 nm-thick polycrystalline Ni films deposited by magnetron sputtering on unpoled piezoelectric (011) [PbMg1/3Nb2/3O3](0.68)-[PbTiO3](0.32) (PMN-PT) substrates. The longitudinal magnetoresistance (MR) of the Ni films on (011) PMN-PT, measured at room temperature in the magnetic field range of -0.3T < mu H-0 < 0.3 T, is found to depend on the crystallographic direction and polarization state of piezosubstrate. Upon poling the PMN-PT substrate, which results in a transfer of strain to the Ni film, the MR value decreases by factor of 20 for the current along [100] of PMN-PT and slightly increases for the [01 (1) over bar] current direction. Simultaneously, a strong increase (decrease) in the field value, where the MR saturates, is observed for the [01 (1) over bar] ([100]) current direction. The anisotropic magnetoresistance is also strongly affected by the remanent strain induced by the electric field pulses applied to the PMN-PT in the non-linear regime revealing a large (132 mT) magnetic anisotropy field. Applying a critical electric field of 2.4 kV/cm, the anisotropy field value changes back to the original value, opening a path to voltage-tuned magnetic field sensor or storage devices. This strain mediated voltage control of the MR and its dependence on the crystallographic direction is correlated with the results of magnetization reversal measurements. (C) 2015 AIP Publishing LLC

    Length Scale of the Spin Seebeck Effect

    Get PDF
    We investigate the origin of the spin Seebeck effect in yttrium iron garnet (YIG) samples for film thicknesses from 20 nm to 50  μm at room temperature and 50 K. Our results reveal a characteristic increase of the longitudinal spin Seebeck effect amplitude with the thickness of the insulating ferrimagnetic YIG, which levels off at a critical thickness that increases with decreasing temperature. The observed behavior cannot be explained as an interface effect or by variations of the material parameters. Comparison to numerical simulations of thermal magnonic spin currents yields qualitative agreement for the thickness dependence resulting from the finite magnon propagation length. This allows us to trace the origin of the observed signals to genuine bulk magnonic spin currents due to the spin Seebeck effect ruling out an interface origin and allowing us to gauge the reach of thermally excited magnons in this system for different temperatures. At low temperature, even quantitative agreement with the simulations is found.United States. Dept. of Energy. Office of Science (Solid-State Solar-Thermal Energy Conversion Center Grant DE-SC0001299)National Science Foundation (U.S.) (Award ECCS1231392
    corecore