34 research outputs found

    Effects of stray capacitance to ground in three electrode monopolar needle bioimpedance measurements

    Get PDF
    Positive phase angle is documented and analyzed in a three electrode monopolar needle measurement. Inductance equivalent behavior of the stray capacitance to ground is described as error source in a non-inductive sample measurement.Postprint (author's final draft

    New Method for Separation of Electrode Polarization Impedance from Measured Tissue Impedance

    Get PDF
    In this paper we have shown that electrode polarization impedance (EPI) can be separated from measured tissue impedance as long as the characteristic frequencies of EPI and tissue are not too close, so that the EPI is largely displayed as a separate dispersion. In 2-electrode measurements the EPI and sample are physically connected in series, and commonly modelled by equivalent components in series. We have calculated the parallel equivalent elements and converted the series connected EPI and sample to a parallel admittance model. By curve fitting on the converted model we have shown that this provides a new method for estimating the EPI with enhanced accuracy compared to similar techniques used on the impedance model

    Invasive Electrical Impedance Tomography for Blood Vessel Detection

    Get PDF
    We present a novel method for localization of large blood vessels using a bioimpedance based needle positioning system on an array of ten monopolar needle electrodes. The purpose of the study is to develop a portable, low cost tool for rapid vascular access for cooling and controlled reperfusion of cardiac arrest patients. Preliminary results show that localization of blood vessels is feasible with this method, but larger studies are necessary to improve the technology

    An Investigation on Bilateral Asymmetry in Electrodermal Activity

    Get PDF
    The Multiple Arousal Theory (Picard et al., 2016) was proposed to explain retrospective observations of bilateral differences in electrodermal activities occurring in threat-related high-stake situations. The theory proposes different cortical and subcortical structures to be involved in the processing of various facets of emotional states. Systematic investigations of this effect are still scarce. This study tested the prediction of bilateral electrodermal effects in a controlled laboratory environment where electrodermal activity (EDA) was recorded bilaterally during normal activity and two stress-tasks in 25 healthy volunteers. A visual search stress task with a performance-related staircase algorithm was used, ensuring intersubjectively comparable stress levels across individuals. After completion of the task, a sense of ownership of an attractive price was created and loss aversion introduced to create a high-stake situation. Confirmation of the theory should satisfy the hypothesis of a bilateral difference in EDA between the dominant and non-dominant hand, which is larger during high-stake stressors than during low-stake stressors. The bilateral difference was quantified and compared statistically between the two stress-tasks, revealing no significant difference between them nor any significant difference between the stress tasks and the period of normal activity. Subgroup analysis of only the participants with maximum self-rating of their desire to win the price (n = 7) revealed neither any significant difference between the two tasks nor between the stress-tasks and the period of normal activity. Although the theory was not confirmed by this study, eight cases suggestive of bilateral difference within the recordings were identified and are presented. Because the study is limited in using one of several possible operationalizations of the phenomenon, it is not possible to draw a general conclusion on the theory. Nevertheless, the study might contribute to a better understanding and encourage systematic review and hypothesis development regarding this new theory. Possible explanations and suggestions for future pathways to systematically investigate the Multiple Arousal Theory are discussed

    Development of a Smart Wireless Multisensor Platform for an Optogenetic Brain Implant

    Get PDF
    Implantable cell replacement therapies promise to completely restore the function of neural structures, possibly changing how we currently perceive the onset of neurodegenerative diseases. One of the major clinical hurdles for the routine implementation of stem cell therapies is poor cell retention and survival, demanding the need to better understand these mechanisms while providing precise and scalable approaches to monitor these cell-based therapies in both pre-clinical and clinical scenarios. This poses significant multidisciplinary challenges regarding planning, defining the methodology and requirements, prototyping and different stages of testing. Aiming toward an optogenetic neural stem cell implant controlled by a smart wireless electronic frontend, we show how an iterative development methodology coupled with a modular design philosophy can mitigate some of these challenges. In this study, we present a miniaturized, wireless-controlled, modular multisensor platform with fully interfaced electronics featuring three different modules: an impedance analyzer, a potentiostat and an optical stimulator. We show the application of the platform for electrical impedance spectroscopy-based cell monitoring, optical stimulation to induce dopamine release from optogenetically modified neurons and a potentiostat for cyclic voltammetry and amperometric detection of dopamine release. The multisensor platform is designed to be used as an opto-electric headstage for future in vivo animal experiments

    Electrosurgery and Temperature Increase in Tissue With a Passive Metal Implant

    Get PDF
    Importance: During monopolar electrosurgery in patients, current paths can be influenced by metal implants, which can cause unintentional tissue heating in proximity to implants. Guidelines concerning electrosurgery and active implants such as pacemakers or implantable cardioverter defibrillators have been published, but most describe interference between electrosurgery and the active implant rather than the risk of unintended tissue heating. Tissue heating in proximity to implants during electrosurgery may cause an increased risk of patient injury.Objective: To determine the temperature of tissue close to metal implants during electrosurgery in an in-vitro model.Design, Setting, and Participants: Thirty tissue samples (15 with a metal implant placed in center, 15 controls without implant) were placed in an in vitro measurement chamber. Electrosurgery was applied at 5–60 W with the active electrode at three defined distances from the implant while temperatures at four defined distances from the implant were measured using fiber-optic sensors.Main Outcomes and Measures: Tissue temperature increase at the four tissue sites was determined for all power levels and each of the electrode-to-implant distances. Based on a linear mixed effects model analysis, the primary outcomes were the difference in temperature increase between implant and control tissue, and the estimated temperature increase per watt per minute.Results: Tissues with an implant had higher temperature increases than controls at all power levels after 1 min of applied electrosurgery (mean difference of 0.16°C at 5 W, 0.50°C at 15 W, 1.11°C at 30 W, and 2.22°C at 60 W, all with p < 0.001). Temperature increase close to the implant was estimated to be 0.088°C/W/min (95% CI: 0.078–0.099°C/W/min; p < 0.001). Temperature could increase to above 43°C after 1 min of 60 W. Active electrode position had no significant effect on temperature increases for tissues with implant (p = 0.6).Conclusions and Relevance: The temperature of tissue close to a metal implant increases with passing electrosurgery current. There is a significant risk of high tissue temperature when long activation times or high power levels are used

    Applications of bioimpedance measurement techniques in tissue engineering

    No full text
    Rapid development in the field of tissue engineering necessitates implementation of monitoring methods for evaluation of the viability and characteristics of the cell cultures in a real-time, non-invasive and non-destructive manner. Current monitoring techniques are mainly histological and require labeling and involve destructive tests to characterize cell cultures. Bioimpedance measurement technique which benefits from measurement of electrical properties of the biological tissues, offers a non-invasive, label-free and real-time solution for monitoring tissue engineered constructs. This review outlines the fundamentals of bioimpedance, as well as electrical properties of the biological tissues, different types of cell culture constructs and possible electrode configuration set ups for performing bioimpedance measurements on these cell cultures. In addition, various bioimpedance measurement techniques and their applications in the field of tissue engineering are discussed
    corecore