16 research outputs found

    Metabolic flux analysis of 3D spheroids reveals significant differences in glucose metabolism from matched 2D cultures of colorectal cancer and pancreatic ductal adenocarcinoma cell lines

    Get PDF
    Background Most in vitro cancer cell experiments have been performed using 2D models. However, 3D spheroid cultures are increasingly favored for being more representative of in vivo tumor conditions. To overcome the translational challenges with 2D cell cultures, 3D systems better model more complex cell-to-cell contact and nutrient levels present in a tumor, improving our understanding of cancer complexity. Despite this need, there are few reports on how 3D cultures differ metabolically from 2D cultures. Methods Well-described cell lines from colorectal cancer (HCT116 and SW948) and pancreatic ductal adenocarcinoma (Panc-1 and MIA-Pa-Ca-2) were used to investigate metabolism in 3D spheroid models. The metabolic variation under normal glucose conditions were investigated comparing 2D and 3D cultures by metabolic flux analysis and expression of key metabolic proteins. Results We find significant differences in glucose metabolism of 3D cultures compared to 2D cultures, both related to glycolysis and oxidative phosphorylation. Spheroids have higher ATP-linked respiration in standard nutrient conditions and higher non-aerobic ATP production in the absence of supplemented glucose. In addition, ATP-linked respiration is significantly inversely correlated with OCR/ECAR (p = 0.0096). Mitochondrial transport protein, TOMM20, expression decreases in all spheroid models compared to 2D, and monocarboxylate transporter (MCT) expression increases in 3 of the 4 spheroid models. Conclusions In this study of CRC and PDAC cell lines, we demonstrate that glucose metabolism in 3D spheroids differs significantly from 2D cultures, both in terms of glycolytic and oxidative phosphorylation metrics. The metabolic phenotype shift from 2D to 3D culture in one cell line is greater than the phenotypic differences between each cell line and tumor source. The results herein emphasize the need to use 3D cell models for investigating nutrient utilization and metabolic flux for a better understanding of tumor metabolism and potential metabolic therapeutic targets.publishedVersio

    Prevalence of PD‑L1 expression is associated with EMAST, density of peritumoral T‑cells and recurrence‑free survival in operable non‑metastatic colorectal cancer

    Get PDF
    Introduction Microsatellite instability (MSI) predict response to anti-PD1 immunotherapy in colorectal cancer (CRC). CRCs with MSI have higher infiltration of immune cells related to a better survival. Elevated Microsatellite Alterations at Tetranucleotides (EMAST) is a form of MSI but its association with PD-L1 expression and immune-cell infiltration is not known. Methods A consecutive, observational cohort of patients undergoing surgery for CRC. EMAST and clinicopathological characteristics were investigated against PD-L1, as well as CD3 and CD8 expression in the invasive margin or tumour centre (Immunoscore). Difference in survival between groups was assessed by log rank test. Results A total of 149 stage I–III CRCs patients, with a median follow up of 60.1 months. Patients with PD-L1+ tumours (7%) were older (median 79 vs 71 years, p = 0.045) and had EMAST+ cancers (OR 10.7, 95% CI 2.2–51.4, p = 0.001). Recurrence-free survival was longer in cancers with PD-L1+ immune cells (HR 0.35, 95% CI 0.16–0.76, p = 0.008, independent of EMAST) and high Immunoscore (HR 0.10, 95% CI 0.01–0.72, p = 0.022). Patients expressing PD-L1 in immune cells had longer disease-specific survival (HR 0.28, 95% CI 0.10–0.77, p = 0.014). Conclusions Higher Immunoscore (CD3/CD8 cells) and expression of tumour PD-L1 is found in CRCs with EMAST. Lymphocytic infiltrate and peritumoral PD-L1 expression have prognostic value in CRC.publishedVersio

    A template to quantify the location and density of CD3 + and CD8 + tumor-infiltrating lymphocytes in colon cancer by digital pathology on whole slides for an objective, standardized immune score assessment

    Get PDF
    Background: In colon cancer, the location and density of tumor-infiltrating lymphocytes (TILs) can classify patients into low and high-risk groups for prognostication. While a commercially available ‘Immunoscore®’ exists, the incurred expenses and copyrights may prevent universal use. The aim of this study was to develop a robust and objective quantification method of TILs in colon cancer. Methods: A consecutive, unselected series of specimens from patients with colon cancer were available for immunohistochemistry and assessment of TILs by automated digital pathology. CD3 + and CD8 + cells at the invasive margin and in tumor center were assessed on consecutive sections using automated digital pathology and image analysis software (Visiopharm®). An algorithm template for whole slide assessment, generated cell counts per square millimeters (cells/mm2), from which the immune score was calculated using distribution volumes. Furthermore, immune score was compared with clinical and histopathological characteristics to confirm its relevance. Results: Based on the quantified TILs numbers by digital image analyses, patients were classified into low (n = 83, 69.7%), intermediate (n = 14, 11.8%) and high (n = 22, 18.5%) immune score groups. High immune score was associated with stage I–II tumors (p = 0.017) and a higher prevalence of microsatellite instable (MSI) tumors (p = 0.030). MSI tumors had a significantly higher numbers of CD3 + TILs in the invasive margin and CD8 + TILs in both tumor center and invasive margin, compared to microsatellite stable (MSS) tumors. Conclusion: A digital template to quantify an easy-to-use immune score corresponds with clinicopathological features and MSI in colon cancer.publishedVersio

    A template to quantify the location and density of CD3 + and CD8 + tumor-infiltrating lymphocytes in colon cancer by digital pathology on whole slides for an objective, standardized immune score assessment

    Get PDF
    Background In colon cancer, the location and density of tumor-infiltrating lymphocytes (TILs) can classify patients into low and high-risk groups for prognostication. While a commercially available ‘Immunoscore®’ exists, the incurred expenses and copyrights may prevent universal use. The aim of this study was to develop a robust and objective quantification method of TILs in colon cancer. Methods A consecutive, unselected series of specimens from patients with colon cancer were available for immunohistochemistry and assessment of TILs by automated digital pathology. CD3 + and CD8 + cells at the invasive margin and in tumor center were assessed on consecutive sections using automated digital pathology and image analysis software (Visiopharm®). An algorithm template for whole slide assessment, generated cell counts per square millimeters (cells/mm2), from which the immune score was calculated using distribution volumes. Furthermore, immune score was compared with clinical and histopathological characteristics to confirm its relevance. Results Based on the quantified TILs numbers by digital image analyses, patients were classified into low (n = 83, 69.7%), intermediate (n = 14, 11.8%) and high (n = 22, 18.5%) immune score groups. High immune score was associated with stage I–II tumors (p = 0.017) and a higher prevalence of microsatellite instable (MSI) tumors (p = 0.030). MSI tumors had a significantly higher numbers of CD3 + TILs in the invasive margin and CD8 + TILs in both tumor center and invasive margin, compared to microsatellite stable (MSS) tumors. Conclusion A digital template to quantify an easy-to-use immune score corresponds with clinicopathological features and MSI in colon cancer.publishedVersio

    Cyclic production of biocompatible few-layer graphene ink with in-line shear-mixing for inkjet-printed electrodes and Li-ion energy storage

    Get PDF
    The scalable production of two-dimensional (2D) materials is needed to accelerate their adoption to industry. In this work, we present a low-cost in-line and enclosed process of exfoliation based on high-shear mixing to create aqueous dispersions of few-layer graphene, on a large scale with a Yw ~ 100% yield by weight and throughput of ϕ ~ 8.3 g h−1. The in-line process minimises basal plane defects compared to traditional beaker-based shear mixing which we attribute to a reduced Reynolds number, Re ~ 105. We demonstrate highly conductive graphene material with conductivities as high as σ ∼ 1.5 × 104 S m−1 leading to sheet-resistances as low as Rs ∼ 2.6 Ω □−1 (t ∼ 25 μm). The process is ideal for formulating non-toxic, biocompatible and highly concentrated (c ∼ 100 mg ml−1) inks. We utilise the graphene inks for inkjet printable conductive interconnects and lithium-ion battery anode composites that demonstrate a low-rate lithium storage capability of 370 mAh g−1, close to the theoretical capacity of graphite. Finally, we demonstrate the biocompatibility of the graphene inks with human colon cells and human umbilical vein endothelial cells at high c ∼ 1 mg ml−1 facilitating a route for the use of the graphene inks in applications that require biocompatibility at high c such as electronic textiles.publishedVersio

    Elevated microsatellite alterations at selected tetranucleotides (EMAST) is not attributed to MSH3 loss in stage I-III colon cancer: An automated, digitalized assessment by immunohistochemistry of whole slides and hot spots

    Get PDF
    INTRODUCTION: EMAST is a poorly understood form of microsatellite instability (MSI) in colorectal cancer (CRC) for which loss of MSH3 has been proposed as the underlying mechanism, based on experimental studies. We aimed to evaluate whether MSH3 loss is associated with EMAST in CRC. METHODS: A consecutive cohort of patients with stage I-III CRC. Digital image analysis using heatmap-derived hot spots investigated MSH3 expression by immunohistochemistry. Fragment analysis of multiplex PCR was used to assess MSI and EMAST, and results cross-examined with MSH3 protein expression. RESULTS: Of 152 patients, EMAST was found in 50 (33%) and exclusively in the colon. Most EMAST-positive cancers had instability at all 5 markers, and EMAST overlapped with MSI-H in 42/50 cases (84%). The most frequently altered tetranucleotide markers were D8S321 (38.2% of tumors) and D20S82 (34.4%). Subjective evaluation of MSH3 expression by IHC in tumor found ≤10% negative tumor cells in all samples, most being ≤5% negative. Digital analysis improved the detection but showed a similar spread of MSH3 loss (range 0.1–15.7%, mean 2.2%). Hotspot MSH3 negativity ranged between 0.1 to 95.0%, (mean 8.6%) with significant correlation with the whole slide analysis (Spearman's rho = 0.677 P < .001). Loss of MSH3 expression did not correlate with EMAST. CONCLUSIONS: In a well-defined cohort of patients with CRC, loss of MSH3 was not associated with EMAST. Further investigation into the mechanisms leading to EMAST in CRC is needed.publishedVersio

    Improved pH-Responsive Release of Phenformin from Low-Defect Graphene Compared to Graphene Oxide

    Get PDF
    Graphene-based drug carriers provide a promising addition to current cancer drug delivery options. Increased accessibility of high-quality graphene made by plasma-enhanced chemical vapor deposition (PE-CVD) makes it an attractive material to revisit in comparison to the widely studied graphene oxide (GO) in drug delivery. Here, we show the potential of repurposing the metabolic drug phenformin for cancer treatment in terms of stability, binding, and pH-responsive release. Using covalent attachment of poly(ethylene glycol) (PEG) onto pristine (PE-CVD) graphene, we show that PEG stabilized graphene nanosheets (PGNS) are stable in aqueous solutions and exhibit higher binding affinity toward phenformin than GO. Moreover, we experimentally demonstrate an improved drug release from PGNS than GO at pH levels lower than physiological conditions, yet comparable to that found in tumor microenvironments.publishedVersio

    Elevated microsatellite alterations at selected tetranucleotides in early-stage colorectal cancers with and without high-frequency microsatellite instability: same, same but different?

    Get PDF
    Microsatellite instability (MSI) is associated with better prognosis in colorectal cancer (CRC). Elevated microsatellite alterations at selected tetranucleotides (EMAST) is a less-understood form of MSI. Here, we aim to investigate the role of EMAST in CRC±MSI related to clinical and tumor-specific characteristics. A consecutive, population-based series of stage I–III colorectal cancers were investigated for MSI and EMAST using PCR primers for 10 microsatellite markers. Of 151 patients included, 33 (21.8%) had MSI and 35 (23.2%) were EMAST+, with an overlap of 77% for positivity, (odds ratio [OR] 61; P < 0.001), and 95% for both markers being negative. EMAST was more prevalent in colon versus rectum (86% vs. 14%, P = 0.004). EMAST+ cancers were significantly more frequent in proximal colon (77 vs. 23%, P = 0.004), had advanced t-stage (T3–4 vs. T1–2 in 94% vs. 6%, respectively; P = 0.008), were larger (≥5 cm vs. <5 cm in 63% and 37%, respectively; P = 0.022) and had poorly differentiated tumor grade (71 vs. 29%, P < 0.01). Furthermore, EMAST+ tumors had a higher median number of harvested lymph nodes than EMAST− (11 vs. 9 nodes; P = 0.03). No significant association was found between EMAST status and age, gender, presence of distant metastases or metastatic lymph nodes, and overall survival. A nonsignificant difference toward worse survival in node-negative colon cancers needs confirmation in larger cohorts. EMAST+ cancers overlap and share features with MSI+ in CRC. Overall, survival was not influenced by the presence of EMAST, but may be of importance in subgroups such as node-negative disease of the colon.publishedVersio

    Metabolic flux analysis of 3D spheroids reveals significant differences in glucose metabolism from matched 2D cultures of colorectal cancer and pancreatic ductal adenocarcinoma cell lines

    No full text
    Background Most in vitro cancer cell experiments have been performed using 2D models. However, 3D spheroid cultures are increasingly favored for being more representative of in vivo tumor conditions. To overcome the translational challenges with 2D cell cultures, 3D systems better model more complex cell-to-cell contact and nutrient levels present in a tumor, improving our understanding of cancer complexity. Despite this need, there are few reports on how 3D cultures differ metabolically from 2D cultures. Methods Well-described cell lines from colorectal cancer (HCT116 and SW948) and pancreatic ductal adenocarcinoma (Panc-1 and MIA-Pa-Ca-2) were used to investigate metabolism in 3D spheroid models. The metabolic variation under normal glucose conditions were investigated comparing 2D and 3D cultures by metabolic flux analysis and expression of key metabolic proteins. Results We find significant differences in glucose metabolism of 3D cultures compared to 2D cultures, both related to glycolysis and oxidative phosphorylation. Spheroids have higher ATP-linked respiration in standard nutrient conditions and higher non-aerobic ATP production in the absence of supplemented glucose. In addition, ATP-linked respiration is significantly inversely correlated with OCR/ECAR (p = 0.0096). Mitochondrial transport protein, TOMM20, expression decreases in all spheroid models compared to 2D, and monocarboxylate transporter (MCT) expression increases in 3 of the 4 spheroid models. Conclusions In this study of CRC and PDAC cell lines, we demonstrate that glucose metabolism in 3D spheroids differs significantly from 2D cultures, both in terms of glycolytic and oxidative phosphorylation metrics. The metabolic phenotype shift from 2D to 3D culture in one cell line is greater than the phenotypic differences between each cell line and tumor source. The results herein emphasize the need to use 3D cell models for investigating nutrient utilization and metabolic flux for a better understanding of tumor metabolism and potential metabolic therapeutic targets

    Graphene-based phenformin carriers for cancer cell treatment: a comparative study between oxidized and pegylated pristine graphene in human cells and zebrafish

    No full text
    Graphene is an attractive choice for the development of an effective drug carrier in cancer treatment due to its high adsorption area and pH-responsive drug affinity. In combination with the highly potent metabolic drug phenformin, increased doses could be efficiently delivered to cancer cells. This study compares the use of graphene oxide (GO) and polyethylene glycol stabilized (PEGylated) pristine graphene nanosheets (PGNSs) for drug delivery applications with phenformin. The cytotoxicity and mitotoxicity of the graphene-based systems were assessed in human cells and zebrafish larvae. Targeted drug release from GO and PGNSs was evaluated at different pH levels known to arise in proliferating tumor microenvironments. PGNSs were less cytotoxic and mitotoxic than GO, and showed an increased release of phenformin at lower pH in cells, compared to GO. In addition, the systemic phenformin effect was mitigated in zebrafish larvae when bound to GO and PGNSs compared to free phenformin, as measured by flavin metabolic lifetime imaging. These results pave the way for improved phenformin-based cancer therapy using graphene nano-sheets, where PGNSs were superior to GO
    corecore