40 research outputs found
Time-dependent simulation of the flow reduction of D2 and T2 in the KATRIN experiment
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to measure the effective electron anti-neutrino mass with an unprecedented sensitivity of 0.2 eV/c², using β-electrons from tritium decay. Superconducting magnets will guide the electrons through a vacuum beamline from the windowless gaseous tritium source through differential and cryogenic pumping sections to a high resolution spectrometer. At the same time tritium gas has to be prevented from entering the spectrometer. Therefore, the pumping sections have to reduce the tritium flow by at least 14 orders of magnitude. This paper describes various simulation methods in the molecular flow regime used to determine the expected gas flow reduction in the pumping sections for deuterium (commissioning runs) and for radioactive tritium. Simulations with MolFlow+ and with an analytical model are compared with each other, and with the stringent requirements of the KATRIN experiment
Neutral tritium gas reduction in the KATRIN differential pumping sections
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to measure the
effective electron anti-neutrino mass with an unprecedented sensitivity of
, using -electrons from tritium decay.
The electrons are guided magnetically by a system of superconducting magnets
through a vacuum beamline from the windowless gaseous tritium source through
differential and cryogenic pumping sections to a high resolution spectrometer
and a segmented silicon pin detector. At the same time tritium gas has to be
prevented from entering the spectrometer. Therefore, the pumping sections have
to reduce the tritium flow by more than 14 orders of magnitude. This paper
describes the measurement of the reduction factor of the differential pumping
section performed with high purity tritium gas during the first measurement
campaigns of the KATRIN experiment. The reduction factor results are compared
with previously performed simulations, as well as the stringent requirements of
the KATRIN experiment.Comment: 19 pages, 4 figures, submitted to Vacuu
Recommended from our members
Improved Upper Limit on the Neutrino Mass from a Direct Kinematic Method by KATRIN.
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic end point at 18.57 keV gives an effective neutrino mass square value of (-1.0_{-1.1}^{+0.9})  eV^{2}. From this, we derive an upper limit of 1.1 eV (90% confidence level) on the absolute mass scale of neutrinos. This value coincides with the KATRIN sensitivity. It improves upon previous mass limits from kinematic measurements by almost a factor of 2 and provides model-independent input to cosmological studies of structure formation
Commissioning of the vacuum system of the KATRIN Main Spectrometer
The KATRIN experiment will probe the neutrino mass by measuring the
beta-electron energy spectrum near the endpoint of tritium beta-decay. An
integral energy analysis will be performed by an electro-static spectrometer
(Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a
volume of 1240 m^3, and a complex inner electrode system with about 120000
individual parts. The strong magnetic field that guides the beta-electrons is
provided by super-conducting solenoids at both ends of the spectrometer. Its
influence on turbo-molecular pumps and vacuum gauges had to be considered. A
system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter
strips has been deployed and was tested during the commissioning of the
spectrometer. In this paper the configuration, the commissioning with bake-out
at 300{\deg}C, and the performance of this system are presented in detail. The
vacuum system has to maintain a pressure in the 10^{-11} mbar range. It is
demonstrated that the performance of the system is already close to these
stringent functional requirements for the KATRIN experiment, which will start
at the end of 2016.Comment: submitted for publication in JINST, 39 pages, 15 figure
Reduction of stored-particle background by a magnetic pulse method at the KATRIN experiment
The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of 0.2 eV/c2 (%90 CL) by precision measurement of the shape of the tritium β-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such as 219Rn and 220Rn, in the spectrometer volume. Active and passive countermeasures have been implemented and tested at the KATRIN main spectrometer. One of these is the magnetic pulse method, which employs the existing air coil system to reduce the magnetic guiding field in the spectrometer on a short timescale in order to remove low- and high-energy stored electrons. Here we describe the working principle of this method and present results from commissioning measurements at the main spectrometer. Simulations with the particle-tracking software Kassiopeia were carried out to gain a detailed understanding of the electron storage conditions and removal processes