46 research outputs found

    Comprehensive assessment of meteorological conditions and airflow connectivity during HCCT-2010

    Get PDF
    This study presents a comprehensive assessment of the meteorological conditions and atmospheric flow dur- ing the Lagrangian-type “Hill Cap Cloud Thuringia 2010” experiment (HCCT-2010), which was performed in Septem- ber and October 2010 at Mt. Schmücke in the Thuringian Forest, Germany and which used observations at three measurement sites (upwind, in-cloud, and downwind) to study physical and chemical aerosol–cloud interactions. A Lagrangian-type hill cap cloud experiment requires not only suitable cloud conditions but also connected airflow condi- tions (i.e. representative air masses at the different measure- ment sites). The primary goal of the present study was to identify time periods during the 6-week duration of the ex- periment in which these conditions were fulfilled and there- fore which are suitable for use in further data examinations. The following topics were studied in detail: (i) the general synoptic weather situations, including the mesoscale flow conditions, (ii) local meteorological conditions and (iii) lo- cal flow conditions. The latter were investigated by means of statistical analyses using best-available quasi-inert trac- ers, SF6 tracer experiments in the experiment area, and re- gional modelling. This study represents the first applica- tion of comprehensive analyses using statistical measures such as the coefficient of divergence (COD) and the cross- correlation in the context of a Lagrangian-type hill cap cloud experiment. This comprehensive examination of local flow connectivity yielded a total of 14 full-cloud events (FCEs), which are defined as periods during which all connected flow and cloud criteria for a suitable Lagrangian-type ex- periment were fulfilled, and 15 non-cloud events (NCEs), which are defined as periods with connected flow but no cloud at the summit site, and which can be used as refer- ence cases. The overall evaluation of the identified FCEs provides the basis for subsequent investigations of the mea- sured chemical and physical data during HCCT-2010 (see http://www.atmos-chem-phys.net/special_issue287.html). Results obtained from the statistical flow analyses and regional-scale modelling performed in this study indicate the existence of a strong link between the three measurement sites during the FCEs and NCEs, particularly under condi- tions of constant southwesterly flow, high wind speeds and slightly stable stratification. COD analyses performed using continuous measurements of ozone and particle (49nm di- ameter size bin) concentrations at the three sites revealed, particularly for COD value

    Registration of ‘Liberty’ Hop

    No full text

    Why GOMS?

    No full text

    Dynamics of Pd Dopant Atoms inside Au Nanoclusters during Catalytic CO Oxidation

    No full text
    Doping gold nanoclusters with palladium has been reported to increase their catalytic activity and stability. PdAu24 nanoclusters, with the Pd dopant atom located at the center of the Au cluster core, were supported on titania and applied in catalytic CO oxidation, showing significantly higher activity than supported monometallic Au25 nanoclusters. After pretreatment, operando DRIFTS spectroscopy detected CO adsorbed on Pd during CO oxidation, indicating migration of the Pd dopant atom from the Au cluster core to the cluster surface. Increasing the number of Pd dopant atoms in the Au structure led to incorporation of Pd mostly in the S-(M-S)n protecting staples, as evidenced by in situ XAFS. A combination of oxidative and reductive thermal pretreatment resulted in the formation of isolated Pd surface sites within the Au surface. The combined analysis of in situ XAFS, operando DRIFTS, and ex situ XPS thus revealed the structural evolution of bimetallic PdAu nanoclusters, yielding a Pd single-site catalyst of 2.7 nm average particle size with improved CO oxidation activity.N.B. thanks the TUW Innovative Project GIP165CDGC. G.R. acknowledges financial support by the Austrian Science Fund (FWF) via grants SFB FOXSI (F4502), DK+ Solids4Fun (W1243), and Single Atom Catalysis (I 4434-N). The authors thank Stephan Pollitt for his advice in synthesizing Pd-doped Au nanoclusters. ALBA synchrotron is acknowledged for beamtime at CLAESS beamline (Proposal ID: 2019023443) and Dr. Vlad Martin-Diaconesu for assistance during measurements

    Critical assessment of meteorological conditions and airflow connectivity during HCCT-2010

    Get PDF
    This study presents a comprehensive and critical assessment of the meteorological conditions and atmospheric flow during the Lagrangian-type "Hill Cap Cloud Thuringia 2010" experiment (HCCT-2010). HCCT-2010 was performed in September and October 2010 at Mt. Schmücke in the Thuringian forest, Germany, applying three measurements sites (upwind, in-cloud, downwind) to study physical and chemical aerosol-cloud-interactions. A Lagrangian-type hill cap cloud experiment requires suitable cloud and particularly connected airflow conditions, i.e. representative air masses at the different measurement sites. Therefore, the present study aimed at the identification of time periods during the 6-weeks duration of the campaign, where such conditions were fulfilled and which can be used in further data examinations. The following topics were studied in detail: (i) the general synoptic weather situations including the mesoscale flow conditions by means of a classification of advected air masses and calculation of non-dimensional flow parameters (e.g. Froude number), (ii) local meteorological conditions, including synoptic front passages, the presence of orographic or frontal cloudiness, cloud base heights and vertical stratification, and (iii) local flow conditions by means of statistical analyses using the quasi-inert trace gas ozone and selected size bins of particle number size distributions as well as SF6 tracer experiments in the campaign area. A comprehensive analyses using statistical measures such as the COD (Coefficient Of Divergence) and cross-correlation have been carried out for the first time in the context of a Lagrangian-type hill cap cloud experiment. Suitable criteria for the aimed statistical analyses were thus developed and applied in the present study to characterise the local flow connectivity in detail. The comprehensive examination resulted in a total of 14 so-called "Full Cloud Events" (FCE), which are shown to conform to the Lagrange-type experimental philosophy of HCCT-2010. In addition, 15 so-called "Non-Cloud Events" (NCEs) could be established, which can be used as reference cases as they provide similarly suitable flow conditions but no cloud at the summit site. Orographic cloudiness was identified for approx. one third of the FCE periods, while about two thirds were associated to synoptic fronts. The statistical flow analyses indicate the existence of a strong link between the sites during the events, particularly under constant south-westerly flow conditions, high wind speeds and slightly stable stratification. The COD analyses using continuously measured concentrations of ozone and the 49 nm diameter particle bin revealed particularly for COD values below 0.1 very consistent time series, i.e. closely linked air masses between the different sites. The cross-correlation analysis revealed under connected flow conditions typical overflow times of about 15 to 30 min between the two valley sites. Additionally, the performed SF6 tracer experiments during the campaign clearly demonstrate that under appropriate meteorological conditions a Lagrangian-type approach is valid and that the connected flow validation procedure developed in this work is suitable for identifying such conditions. Finally, an overall evaluation of the identified FCEs is presented, which provides the basis for subsequent investigations of the measured chemical and physical data during HCCT-2010
    corecore