152 research outputs found

    European Society of Paediatric Radiology Computed Tomography and Dose Task Force : European guidelines on diagnostic reference levels for paediatric imaging

    Get PDF
    The recent European Council Directive 2013/59/EURATOM requires the establishment of diagnostic reference levels (DRLs) to optimise radiation dose in diagnostic and interventional radiology procedures. At the time this directive was enacted, just a few European countries had already set paediatric DRLs and many of these were outdated. For this reason, the European Commission launched a project addressing European Guidelines on Diagnostic Reference Levels for Paediatric Imaging that was awarded to a consortium led by the European Society of Radiology with the collaboration of the European Society of Paediatric Radiology and other European stakeholders involved in the radiation protection of children. The main aims of this project were to establish European DRLs to be used by countries without their own national paediatric DRLs and to provide a consistent method to establish new DRLs in the future. These European guidelines have been very recently endorsed by the European Commission and published in issue N degrees 185 of the Radiation Protection series. The purpose of this article is to introduce these guidelines to the wide community of paediatric radiologists.Peer reviewe

    Protecting sensitive patient groups from imaging using ionizing radiation: effects during pregnancy, in fetal life and childhood

    Get PDF
    The frequency of imaging examinations requiring radiation exposure in children (especially CT) is rapidly increasing. This paper reviews the current evidence in radiation protection in pediatric imaging, focusing on the recent knowledge of the biological risk related to low doses exposure. Even if there are no strictly defined limits for patient radiation exposure, it is recommended to try to keep doses as low as reasonably achievable (the ALARA principle). To achieve ALARA, several techniques to reduce the radiation dose in radiation-sensitive patients groups are reviewed. The most recent recommendations that provide guidance regarding imaging of pregnant women are also summarized, and the risk depending on dose and phase of pregnancy is reported. Finally, the risk-benefit analysis of each examination, and careful communication of this risk to the patient, is emphasized

    European Society of Paediatric Radiology 2019 strategic research agenda: improving imaging for tomorrow’s children

    Get PDF
    The European Society of Paediatric Radiology (ESPR) research committee was established to initiate, drive forward and foster excellence in paediatric imaging, paediatric image-guided intervention and radiation protection research, by facilitating more evidence-based standards, protocols and multi-institutional collaborations. The ESPR Strategic Research Agenda outlines our current research approach, highlighting several areas of paediatric imaging where the society can help guide current and future research, and emphasizing those areas where early research (“seed”) funding may need to be allocated by this and other societies as precursors to larger grant applications. The key aims are to evaluate normal variation in order to be able to confidently diagnose disease states, develop robust image-based classification systems to aid diagnosis and treatment monitoring, and help develop evidence-based clinical guidelines using current literature and experience to identify knowledge gaps. For this reason, the development of evidence-based imaging pipelines, broken down step-by-step to include diagnosis, classification and clinical effectiveness, should be the end goal for each disease entity for each affected child. Here, we outline the 2019 ESPR Strategic Research Agenda along three points in the clinical imaging pipeline: clinical referral, disease diagnosis and evolution, and clinical therapeutic evaluation and effectiveness. Through multicentre trials, using existing high-level experience and expertise, and nurturing the next generation of researchers, we will be able to achieve these aims.publishedVersio

    Ultrafiltrazione peritoneale e sindrome cardiorenale: gestione del sovraccarico di fluidi e ruolo del sodio

    Get PDF
    Congestion represents a crucial clinical component of both heart failure and cardiorenal syndrome and it has been postulated to modulate heart and kidney cross-link. Diuretic therapy is a corner stone in the treatment patients with heart failure, and renal replacement therapies are mainly used for patients with refractory heart failure who have not reached the worst stages of renal disfunction. Peritoneal dialysis is a home-based therapeutic modality providing both solute clearance and ultrafiltration, together with relief from congestion in decompensated heart failure patients. The following review will focus on sodium removal in refractory decompensated heart failure patients undergoing peritoneal dialysis. (Cardionephrology

    Successful treatment of Neuroblastoma in an adolescent with intra-arterial embolization before surgery

    Get PDF
    Abstract Introduction Neuroblastoma in the adolescent is characterized by indolent growth and poor outcome. Surgical resection of the tumor is an essential part of the multimodality treatment. Surgical complications depend on the presence of Image Defined Risk Factors (IDRFs). Methods We present an adolescent with pelvic neuroblastoma and epidural compression. To facilitate tumor resection, the patient underwent preoperative selective embolization. Results After selective embolization a subsequent complete resection etraspinal localisation was performed without complication with complete remission after 2 years. Conclusions Preoperative embolization is a safe and feasible technique that can help pediatric surgical oncologist to reduce complications IDRFs-related

    Exploring the low-mass regime of galaxy-scale strong lensing: Insights into the mass structure of cluster galaxies

    Full text link
    We aim at a direct measurement of the compactness of three galaxy-scale lenses in massive clusters, testing the accuracy of the scaling laws that describe the members in strong lensing (SL) models of galaxy clusters. We selected the multiply imaged sources MACS J0416.1-2403 ID14 (z=3.221z=3.221), MACS J0416.1-2403 ID16 (z=2.095z=2.095), and MACS J1206.2-0847 ID14 (z=3.753z=3.753). Eight images were observed for the first SL system, and six for the latter two. We focused on the main deflector of each galaxy-scale SL system (identified as members 8971, 8785, and 3910, respectively), and modelled its total mass distribution with a truncated isothermal sphere. We accounted for the lensing effects of the remaining cluster components, and included the uncertainty on the cluster-scale mass distribution through a bootstrapping procedure. We measured a truncation radius value of 6.11.1+2.3kpc6.1^{+2.3}_{-1.1} \, \mathrm{kpc}, 4.00.4+0.6kpc4.0^{+0.6}_{-0.4} \, \mathrm{kpc}, and 5.21.1+1.3kpc5.2^{+1.3}_{-1.1} \, \mathrm{kpc} for members 8971, 8785, and 3910, respectively. Alternative non-truncated models with a higher number of free parameters do not lead to an improved description of the SL system. We measured the stellar-to-total mass fraction within the effective radius ReR_e for the three members, finding 0.51±0.210.51\pm0.21, 1.0±0.41.0\pm0.4, and 0.39±0.160.39\pm0.16, respectively. We find that a parameterisation of the properties of cluster galaxies in SL models based on power-law scaling relations with respect to the total luminosity cannot accurately describe their compactness over their full total mass range. Our results agree with modelling of the cluster members based on the Fundamental Plane relation. Finally, we report good agreement between our values of the stellar-to-total mass fraction within ReR_e and those of early-type galaxies from the SLACS Survey. Our work significantly extends the regime of the current samples of lens galaxies.Comment: Astronomy & Astrophysics, 679, A124 (2023), 15 pages, 12 figures, 8 table

    Qualitative and quantitative analysis of doctor-patient interactions during andrological consultations

    Get PDF
    Although a trustworthy connection between doctor and patient is crucial in clinical practice, it could be hindered by different cultural and linguistic backgrounds. Moreover, an effective doctor-patient interaction could be even more challenging in andrological fields, in which psychological and social components are predominant

    Radiomic and Artificial Intelligence Analysis with Textural Metrics, Morphological and Dynamic Perfusion Features Extracted by Dynamic Contrast-Enhanced Magnetic Resonance Imaging in the Classification of Breast Lesions

    Get PDF
    The aim of the study was to estimate the diagnostic accuracy of textural, morpho- logical and dynamic features, extracted by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) images, by carrying out univariate and multivariate statistical analyses including artificial intelligence approaches. Methods: In total, 85 patients with known breast lesion were enrolled in this retrospective study according to regulations issued by the local Institutional Review Board. All patients underwent DCE-MRI examination. The reference standard was pathology from a surgical specimen for malignant lesions and pathology from a surgical specimen or fine needle aspiration cytology, core or Tru-Cut needle biopsy for benign lesions. In total, 91 samples of 85 patients were ana- lyzed. Furthermore, 48 textural metrics, 15 morphological and 81 dynamic parameters were extracted by manually segmenting regions of interest. Statistical analyses including univariate and multivari- ate approaches were performed: non-parametric Wilcoxon–Mann–Whitney test; receiver operating characteristic (ROC), linear classifier (LDA), decision tree (DT), k-nearest neighbors (KNN), and support vector machine (SVM) were utilized. A balancing approach and feature selection methods were used. Results: The univariate analysis showed low accuracy and area under the curve (AUC) for all considered features. Instead, in the multivariate textural analysis, the best performance (accuracy (ACC) = 0.78; AUC = 0.78) was reached with all 48 metrics and an LDA trained with balanced data. The best performance (ACC = 0.75; AUC = 0.80) using morphological features was reached with an SVM trained with 10-fold cross-variation (CV) and balanced data (with adaptive synthetic (ADASYN) function) and a subset of five robust morphological features (circularity, rectangularity, sphericity, gleaning and surface). The best performance (ACC = 0.82; AUC = 0.83) using dynamic features was reached with a trained SVM and balanced data (with ADASYN function). Conclusion: Multivariate analyses using pattern recognition approaches, including all morphological, textural and dynamic features, optimized by adaptive synthetic sampling and feature selection operations obtained the best results and showed the best performance in the discrimination of benign and malignant lesions

    Digital breast tomosynthesis and contrast-enhanced dual-energy digital mammography alone and in combination compared to 2D digital synthetized mammography and MR imaging in breast cancer detection and classification.

    Get PDF
    To compare diagnostic performance of contrast-enhanced dual-energy digital mammography (CEDM) and digital breast tomosynthesis (DBT) alone and in combination compared to 2D digital mammography (MX) and dynamic contrast-enhanced MRI (DCE-MRI) in women with breast lesions. We enrolled 100 consecutive patients with breast lesions (BIRADS 3-5 at imaging or clinically suspicious). CEDM, DBT, and DCE-MRI 2D were acquired. Synthetized MX was obtained by DBT. A total of 134 lesions were investigated on 111 breasts of 100 enrolled patients: 53 were histopathologically proven as benign and 81 as malignant. Nonparametric statistics and receiver operating characteristic (ROC) curve were performed. Two-dimensional synthetized MX showed an area under ROC curve (AUC) of 0.764 (sensitivity 65%, specificity 80%), while AUC was of 0.845 (sensitivity 80%, specificity 82%) for DBT, of 0.879 (sensitivity 82%, specificity 80%) for CEDM, and of 0.892 (sensitivity 91%, specificity 84%) for CE-MRI. DCE-MRI determined an AUC of 0.934 (sensitivity 96%, specificity 88%). Combined CEDM with DBT findings, we obtained an AUC of 0.890 (sensitivity 89%, specificity 74%). A difference statistically significant was observed only between DCE-MRI and CEDM (P = .03). DBT, CEDM, CEDM combined to tomosynthesis, and DCE-MRI had a high ability to identify multifocal and bilateral lesions with a detection rate of 77%, 85%, 91%, and 95% respectively, while 2D synthetized MX had a detection rate for multifocal lesions of 56%. DBT and CEDM have superior diagnostic accuracy of 2D synthetized MX to identify and classify breast lesions, and CEDM combined with DBT has better diagnostic performance compared with DBT alone. The best results in terms of diagnostic performance were obtained by DCE-MRI. Dynamic information obtained by time-intensity curve including entire phase of contrast agent uptake allows a better detection and classification of breast lesions
    corecore