863 research outputs found
Polynomial Chaos Expansion method as a tool to evaluate and quantify field homogeneities of a novel waveguide RF Wien Filter
For the measurement of the electric dipole moment of protons and deuterons, a
novel waveguide RF Wien filter has been designed and will soon be integrated at
the COoler SYnchrotron at J\"ulich. The device operates at the harmonic
frequencies of the spin motion. It is based on a waveguide structure that is
capable of fulfilling the Wien filter condition ()
\textit{by design}. The full-wave calculations demonstrated that the waveguide
RF Wien filter is able to generate high-quality RF electric and magnetic
fields. In reality, mechanical tolerances and misalignments decrease the
simulated field quality, and it is therefore important to consider them in the
simulations. In particular, for the electric dipole moment measurement, it is
important to quantify the field errors systematically. Since Monte-Carlo
simulations are computationally very expensive, we discuss here an efficient
surrogate modeling scheme based on the Polynomial Chaos Expansion method to
compute the field quality in the presence of tolerances and misalignments and
subsequently to perform the sensitivity analysis at zero additional
computational cost.Comment: 12 pages, 19 figure
Near-Infrared Sensitized Photocathodes and Film Sensitivities for Typical Xenon-Lamp Radiation and Related Subjects
Author Institution: Solid State Physics Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433Weighting or assessment factors of near-infrared photocathodes and Kodak 5424 film are determined for xenon-lamp illumination. These values are important for selecting detectors and determining the basic sensitivity for a given situation and instrumentation; for example, in medicine, when obtaining retinal pictures. Some other typical applications are also discussed. Charts showing the radiation from a xenon-arc lamp, with a 0.5 mm arc length and 800 watt input, and the typical efficiency values of photocathodes and film to xenon-lamp radiation are presented at spectral intervals of 20 nm for the range of 400 to 1100 nm, with and without Kodak Wratten filter 89b
Validity and Reliability of Fitbit Flex for Step Count, Moderate to Vigorous Physical Activity and Activity Energy Expenditure.
OBJECTIVES: To examine the validity and reliability of the Fitbit Flex against direct observation for measuring steps in the laboratory and against the Actigraph for step counts in free-living conditions and for moderate-to-vigorous physical activity (MVPA) and activity energy expenditure (AEE) overall. METHODS: Twenty-five adults (12 females, 13 males) wore a Fitbit Flex and an Actigraph GT3X+ during a laboratory based protocol (including walking, incline walking, running and stepping) and free-living conditions during a single day period to examine measurement of steps, AEE and MVPA. Twenty-four of the participants attended a second session using the same protocol. RESULTS: Intraclass correlations (ICC) for test-retest reliability of the Fitbit Flex were strong for walking (ICC = 0.57), moderate for stair stepping (ICC = 0.34), and weak for incline walking (ICC = 0.22) and jogging (ICC = 0.26). The Fitbit significantly undercounted walking steps in the laboratory (absolute proportional difference: 21.2%, 95%CI 13.0-29.4%), but it was more accurate, despite slightly over counting, for both jogging (6.4%, 95%CI 3.7-9.0%) and stair stepping (15.5%, 95%CI 10.1-20.9%). The Fitbit had higher coefficients of variation (Cv) for step counts compared to direct observation and the Actigraph. In free-living conditions, the average MVPA minutes were lower in the Fitbit (35.4 minutes) compared to the Actigraph (54.6 minutes), but AEE was greater from the Fitbit (808.1 calories) versus the Actigraph (538.9 calories). The coefficients of variation were similar for AEE for the Actigraph (Cv = 36.0) and Fitbit (Cv = 35.0), but lower in the Actigraph (Cv = 25.5) for MVPA against the Fitbit (Cv = 32.7). CONCLUSION: The Fitbit Flex has moderate validity for measuring physical activity relative to direct observation and the Actigraph. Test-rest reliability of the Fitbit was dependant on activity type and had greater variation between sessions compared to the Actigraph. Physical activity surveillance studies using the Fitbit Flex should consider the potential effect of measurement reactivity and undercounting of steps
Proton-conducting polymer electrolyte membranes based on fluoropolymers incorporating perfluorovinyl ether sulfonic acids and fluoroalkenes Synthesis and characterizations
International audienceThis paper presents the synthesis of new polymer electrolyte membranes based on fluoropolymers incorporating aromatic perfluorovinyl ether sulfonic acids. A novel synthetic route describing the preparation of perfluorovinyl ether monomer containing sulfonic functionalities, 4-[(alpha,beta,beta-trifluorovinyl)oxy]benzene sulfonic acid (TFVOBSA), is reported. The radical (co) and terpolymerization of 4-[(alpha,beta,beta-trifluorovinyl)oxy]benzene sulfonyl chloride (TFVOBSC) with 1,1-difluoroethylene (or vinylidene fluoride, VDF), hexafluoropropene (HFP), and perfluoromethyl vinyl ether (PMVE) is described. The terpolymers of TFVOBSC with VDF and HFP, or VDF and PMVE, were hydrolyzed and led also to original fluorinated terpolymers bearing sulfonic acid aromatic side-group. The terpolymers were characterized by 1H and 19F NMR spectroscopies, SEC, DSC and TGA. Membranes incorporating these functional fluoropolymers were prepared and the electrochemical (IEC, proton conductivity, swelling rates) properties were studied and discussed
Electromagnetic Simulation and Design of a Novel Waveguide RF Wien Filter for Electric Dipole Moment Measurements of Protons and Deuterons
The conventional Wien filter is a device with orthogonal static magnetic and
electric fields, often used for velocity separation of charged particles. Here
we describe the electromagnetic design calculations for a novel waveguide RF
Wien filter that will be employed to solely manipulate the spins of protons or
deuterons at frequencies of about 0.1 to 2 MHz at the COoler SYnchrotron COSY
at J\"ulich. The device will be used in a future experiment that aims at
measuring the proton and deuteron electric dipole moments, which are expected
to be very small. Their determination, however, would have a huge impact on our
understanding of the universe.Comment: 10 pages, 10 figures, 4 table
The prevalence of loneliness across 113 countries: systematic review and meta-analysis.
OBJECTIVES: To identify data availability, gaps, and patterns for population level prevalence of loneliness globally, to summarise prevalence estimates within World Health Organization regions when feasible through meta-analysis, and to examine temporal trends of loneliness in countries where data exist. DESIGN: Systematic review and meta-analysis. DATA SOURCES: Embase, Medline, PsycINFO, and Scopus for peer reviewed literature, and Google Scholar and Open Grey for grey literature, supplemented by backward reference searching (to 1 September 2021) ELIGIBILITY CRITERIA FOR SELECTING STUDIES: Observational studies based on nationally representative samples (n≥292), validated instruments, and prevalence data for 2000-19. Two researchers independently extracted data and assessed the risk of bias using the Joanna Briggs Institute checklist. Random effects meta-analysis was conducted in the subset of studies with relatively homogeneous research methods by measurement instrument, age group, and WHO region. RESULTS: Prevalence data were available for 113 countries or territories, according to official WHO nomenclature for regions, from 57 studies. Data were available for adolescents (12-17 years) in 77 countries or territories, young adults (18-29 years) in 30 countries, middle aged adults (30-59 years) in 32 countries, and older adults (≥60 years) in 40 countries. Data for all age groups except adolescents were lacking outside of Europe. Overall, 212 estimates for 106 countries from 24 studies were included in meta-analyses. The pooled prevalence of loneliness for adolescents ranged from 9.2% (95% confidence interval 6.8% to 12.4%) in South-East Asia to 14.4% (12.2% to 17.1%) in the Eastern Mediterranean region. For adults, meta-analysis was conducted for the European region only, and a consistent geographical pattern was shown for all adult age groups. The lowest prevalence of loneliness was consistently observed in northern European countries (2.9%, 1.8% to 4.5% for young adults; 2.7%, 2.4% to 3.0% for middle aged adults; and 5.2%, 4.2% to 6.5% for older adults) and the highest in eastern European countries (7.5%, 5.9% to 9.4% for young adults; 9.6%, 7.7% to 12.0% for middle aged adults; and 21.3%, 18.7% to 24.2% for older adults). CONCLUSION: Problematic levels of loneliness are experienced by a substantial proportion of the population in many countries. The substantial difference in data coverage between high income countries (particularly Europe) and low and middle income countries raised an important equity issue. Evidence on the temporal trends of loneliness is insufficient. The findings of this meta-analysis are limited by data scarcity and methodological heterogeneity. Loneliness should be incorporated into general health surveillance with broader geographical and age coverage, using standardised and validated measurement tools. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42019131448
PRIMAP-crf: UNFCCC CRF data in IPCC 2006 categories
All Annex I Parties to the United Nations Framework Convention on Climate
Change (UNFCCC) are required to report domestic emissions on an annual basis
in a Common Reporting Format (CRF). In 2015, the CRF data reporting was
updated to follow the more recent 2006 guidelines from the IPCC and the
structure of the reporting tables was modified accordingly. However, the
hierarchical categorisation of data in the IPCC 2006 guidelines is not
readily extracted from the reporting tables. In this paper, we present the
PRIMAP-crf data as a re-constructed hierarchical dataset according to the
IPCC 2006 guidelines. Furthermore, the data are organised in a series of tables containing all available
countries and years for each individual gas and category reported. It is
therefore readily usable for climate policy assessment, such as the
quantification of emissions reduction targets.In addition to single gases, the Kyoto basket of greenhouse gases
(CO2, N2O, CH4, HFCs, PFCs, SF6, and
NF3) is provided according to multiple global warming potentials. The
dataset was produced using the PRIMAP emissions module. Key processing steps
include extracting data from submitted CRF Excel spreadsheets, mapping CRF
categories to IPCC 2006 categories, constructing missing categories from
available data, and aggregating single gases to gas baskets. Finally, we
describe key aspects of the data with relevance for climate policy: the
contribution of NF3 to national totals, changes in data reported over
subsequent years, and issues or difficulties encountered when processing
currently available data. The processed data are available under an Open Data
CC BY 4.0 license, and are available at
https://doi.org/10.5880/pik.2018.001.</p
- …