10,375 research outputs found

    Effect of proof testing on the flaw growth characteristics of 304 stainless steel

    Get PDF
    The effects of proof overload frequency and magnitude on the cyclic crack growth rates of 304 stainless steel weldments were investigated. The welding procedure employed was typical of those used on over-the-road cryogenic vessels. Tests were conducted at room temperature with an overload ratio of 1.50 to determine the effect of overload frequency. Effect of overload magnitude was determined from tests where a room temperature overload was applied between blocks of 1000 cycles applied at 78 K (-320 F). The cyclic stress level used in all tests was typical of the nominal membrane stress generally encountered in full scale vessels. Test results indicate that judicious selection of proof overload frequency and magnitude can reduce crack growth rates for cyclic stress levels

    Auditing the TPACK confidence of Australian pre-service teachers: the TPACK confidence survey (TCS)

    Get PDF
    This chapter describes the construction and validation of an instrument to measure teachers’ Technological Pedagogical Content Knowledge (TPACK). The TPACK Confidence Survey (TCS) contains scales that measure teachers’ attitudes toward using ICT; confidence to use ICT for teaching and learning tasks (TPACK); competency with ICT; Technology Knowledge (TK); and TPACK Vocational Self-efficacy. The scale measuring TPACK confidence uses the Learning With ICTs: Measuring ICT Use in the Curriculum instrument that has been evaluated and reported previously. This paper proposes that the TCS provides a valid and reliable instrument with which to audit teachers’ TPACK confidence

    Fracture characteristics of structural aerospace alloys containing deep surface flaws

    Get PDF
    Conditions controlling the growth and fracture of deep surface flaws in aerospace alloys were investigated. Static fracture tests were performed on 7075-T651 and 2219-T87 aluminum, and 6Ai-4V STA titanium . Cyclic flaw growth tests were performed on the two latter alloys, and sustain load tests were performed on the titanium alloy. Both the cyclic and the sustain load tests were performed with and without a prior proof overload cycle to investigate possible growth retardation effects. Variables included in all test series were thickness, flaw depth-to-thickness ratio, and flaw shape. Results were analyzed and compared with previously developed data to determine the limits of applicability of available modified linear elastic fracture solutions

    Investigation of deep flaws in thin walled tanks

    Get PDF
    Growth of deep surface flaws in thin wall tanks of aluminum and titanium base metal

    Mid-Infrared Instrumentation for the European Extremely Large Telescope

    Full text link
    MIDIR is the proposed thermal/mid-IR imager and spectrograph for the European Extremely Large Telescope (E-ELT). It will cover the wavelength range of 3 to at least 20 microns. Designed for diffraction-limited performance over the entire wavelength range, MIDIR will require an adaptive optics system; a cryogenically cooled system could offer optimal performance in the IR, and this is a critical aspect of the instrument design. We present here an overview of the project, including a discussion of MIDIR's science goals and a comparison with other infrared (IR) facilities planned in the next decade; top level requirements derived from these goals are outlined. We describe the optical and mechanical design work carried out in the context of a conceptual design study, and discuss some important issues to emerge from this work, related to the design, operation and calibration of the instrument. The impact of telescope optical design choices on the requirements for the MIDIR instrument is demonstrated.Comment: for publication in SPIE Proceedings vol. 6692, Cryogenic Optical Systems and Instrumentation XII, eds. J.B. Heaney and L.G. Burriesci, San Diego, Aug 200

    The pre-outburst flare of the A 0535+26 August/September 2005 outburst

    Get PDF
    We study the spectral and temporal behavior of the High Mass X-ray Binary A 0535+26 during a `pre-outburst flare' which took place ~5 d before the peak of a normal (type I) outburst in August/September 2005. We compare the studied behavior with that observed during the outburst. We analyse RXTE observations that monitored A 0535+26 during the outburst. We complete spectral and timing analyses of the data. We study the evolution of the pulse period, present energy-dependent pulse profiles both at the initial pre-outburst flare and close to outburst maximum, and measure how the cyclotron resonance-scattering feature (hereafter CRSF) evolves. We present three main results: a constant period P=103.3960(5)s is measured until periastron passage, followed by a spin-up with a decreasing period derivative of Pdot=(-1.69+/-0.04)x10^(-8)s/s at MJD 53618, and P remains constant again at the end of the main outburst. The spin-up provides evidence for the existence of an accretion disk during the normal outburst. We measure a CRSF energy of Ecyc~50kev during the pre-outburst flare, and Ecyc~46kev during the main outburst. The pulse shape, which varies significantly during both pre-outburst flare and main outburst, evolves strongly with photon energy.Comment: 4 pages, 4 figures, accepted for publication in A&A Letters. To be published in parallel to Postnov et al. 200

    Analysis and Test of Deep Flaws in Thin Sheets of Aluminum and Titanium. Volume 2: Crack Opening Displacement and Stress-Strain Data

    Get PDF
    Static fracture tests were performed on surface flawed specimens of aluminum and titanium alloys. A simulated proof overload cycle was applied prior to all of the cyclic tests. Variables included in each test series were flaw shapes and thickness. Additionally, test temperature was a variable for the aluminum test series. The crack opening displacement and stress-strain data obtained are presented

    Digital compensation of the side-band-rejection ratio in a fully analog 2SB sub-millimeter receiver

    Get PDF
    In observational radio astronomy, sideband-separating receivers are preferred, particularly under high atmospheric noise, which is usually the case in the sub-millimeter range. However, obtaining a good rejection ratio between the two sidebands is difficult since, unavoidably, imbalances in the different analog components appear. We describe a method to correct these imbalances without making any change in the analog part of the sideband-separating receiver, specifically, keeping the intermediate-frequency hybrid in place. This opens the possibility of implementing the method in any existing receiver. We have built hardware to demonstrate the validity of the method and tested it on a fully analog receiver operating between 600 and 720GHz. We have tested the stability of calibration and performance vs time and after full resets of the receiver. We have performed an error analysis to compare the digital compensation in two configurations of analog receivers, with and without intermediate frequency (IF) hybrid. An average compensated sideband rejection ratio of 46dB is obtained. Degradation of the compensated sideband rejection ratio on time and after several resets of the receiver is minimal. A receiver with an IF hybrid is more robust to systematic errors. Moreover, we have shown that the intrinsic random errors in calibration have the same impact for configuration without IF hybrid and for a configuration with IF hybrid with analog rejection ratio better than 10dB. Compensated rejection ratios above 40dB are obtained even in the presence of high analog rejection. The method is robust allowing its use under normal operational conditions at any telescope. We also demonstrate that a full analog receiver is more robust against systematic errors. Finally, the error bars associated to the compensated rejection ratio are almost independent of whether IF hybrid is present or not
    • …
    corecore