2,553 research outputs found
The Performance of the LHCb Muon Identification Procedure
This note describes the LHCb offline muon identification procedure and the algorithm parameters tuning using a Monte Carlo sample of B -> J Psi Ks events. The performance is also presented for a sample of b-bbar inclusive events
The Muon Identification Procedure of the LHCb Experiment for the First Data
We present a refined muon identification algorithm for the LHCb experiment suitable for the first period of data taking. The new algorithm is robust against possible inefficiencies of the Muon Detector and takes properly into account the momentum dependence, so it can be tuned with calibration samples and exported to signal samples with different momentum spectra without large corrections. The average performance depends on the momentum spectrum of the analyzed sample: with the current simulation we find for tracks with p > 3 GeV/c in a generic b-inclusive sample a muon identification efficiency of 90 % for a misidentification rate of hadrons and electrons of ~2.4 % (~ 1 % excluding pi's and K's decays in flight). Additional rejection power can be obtained by combining in a proper way the informations coming from all the other subdetectors in a global Likelihood: in this case for a muon identification efficiency of 90 % we find a misidentification rate of ~1.8 % (~ 0.8 % excluding pi's and K's decays in flight
Performance of a multigap RPC prototype for the LHCb muon system
Several technologies are under consideration for the muon system of the LHCb experiment. Resistive Plate Chambers (RPCs) are one of the favourite candidates for the outer areas where the particle fluxes are expected to be at most some kHz/cm/sup 2/. This work describes the results obtained with a multigap RPC prototype under various beam conditions at the CERN facilities. (9 refs)
Performance of the Muon Identification at LHCb
The performance of the muon identification in LHCb is extracted from data
using muons and hadrons produced in J/\psi->\mu\mu, \Lambda->p\pi and
D^{\star}->\pi D0(K\pi) decays. The muon identification procedure is based on
the pattern of hits in the muon chambers. A momentum dependent binary
requirement is used to reduce the probability of hadrons to be misidentified as
muons to the level of 1%, keeping the muon efficiency in the range of 95-98%.
As further refinement, a likelihood is built for the muon and non-muon
hypotheses. Adding a requirement on this likelihood that provides a total muon
efficiency at the level of 93%, the hadron misidentification rates are below
0.6%.Comment: 17 pages, 10 figure
Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency
A method is described which allows to deduce the dead-time of the front-end
electronics of the LHCb muon detector from a series of measurements performed
at different luminosities at a bunch-crossing rate of 20 MHz. The measured
values of the dead-time range from 70 ns to 100 ns. These results allow to
estimate the performance of the muon detector at the future bunch-crossing rate
of 40 MHz and at higher luminosity
Gas Gain Uniformity Tests performed on Multi Wire Proportional Chambers for the LHCb Muon System
We present the experimental setup and the results of the gas gain uniformity tests performed as part of the quality control of the multiwire proportional chambers produced at CERN for the LHCb Muon system. The test provides a relative gas gain measurement over the whole chamber sensitive area. It is based on the analysis of the pulse height spectrum obtained when the chamber is exposed to {a^241}Am radioactive source. Since the measurement is normalized to the peak of a precise pulse generator, the gain uniformity can also be evaluated among different gas gaps and different chambers
A Measurement of the Ds+ Lifetime
A high statistics measurement of the Ds+ lifetime from the Fermilab
fixed-target FOCUS photoproduction experiment is presented. We describe the
analysis of the two decay modes, Ds+ -> phi(1020)pi+ and Ds+ ->
\bar{K}*(892)0K+, used for the measurement. The measured lifetime is 507.4 +/-
5.5 (stat.) +/- 5.1 (syst.) fs using 8961 +/- 105 Ds+ -> phi(1020)pi+ and 4680
+/- 90 Ds+ -> \bar{K}*(892)0K+ decays. This is a significant improvement over
the present world average.Comment: 5 pages, 3 figures, 2 tables, submitted to PR
Performance of the LHCb muon system
The performance of the LHCb Muon system and its stability across the full
2010 data taking with LHC running at ps = 7 TeV energy is studied. The
optimization of the detector setting and the time calibration performed with
the first collisions delivered by LHC is described. Particle rates, measured
for the wide range of luminosities and beam operation conditions experienced
during the run, are compared with the values expected from simulation. The
space and time alignment of the detectors, chamber efficiency, time resolution
and cluster size are evaluated. The detector performance is found to be as
expected from specifications or better. Notably the overall efficiency is well
above the design requirementsComment: JINST_015P_1112 201
Results of the MWPC gas gain uniformity tests performed at CERN
We present the results of the gas gain uniformity tests performed as part of the quality control of the multiwire proportional chambers produced at CERN for the LHCb Muon system, along with a description of the last hardware and software upgrades. The test provides a relative gas gain measurement over the whole chamber sensitive area. It is based on the analysis of the spectrum obtained when the chamber is exposed to a Am radioactive source. Since the measurement is normalized to the peak of a precise pulse generator, the gain uniformity can also be evaluated among different gas gaps and different chambers
- âŠ