12 research outputs found

    Registration of a Validated Mechanical Atlas of Middle Ear for Surgical Simulation

    Get PDF
    International audienceThis paper is centered on the development of a new train- ing and rehearsal simulation system for middle ear surgery. First, we have developed and validated a mechanical atlas based on finite element method of the human middle ear. The atlas is based on a microMRI. Its mechanical behavior computed in real-time has been successfully val- idated. In addition, we propose a method for the registration of the mechanical atlas on patient imagery. The simulation can be used for a rehearsal surgery with the geometrical anatomy of a given patient and with mechanical data that are validated. Moreover, this process does not necessitate a complete re-built of the model

    An international review of laser Doppler vibrometry:Making light work of vibration measurement

    Get PDF
    © 2016 In 1964, just a few years after the invention of the laser, a fluid velocity measurement based on the frequency shift of scattered light was made and the laser Doppler technique was born. This comprehensive review paper charts advances in the development and applications of laser Doppler vibrometry (LDV) since those first pioneering experiments. Consideration is first given to the challenges that continue to be posed by laser speckle. Scanning LDV is introduced and its significant influence in the field of experimental modal analysis described. Applications in structural health monitoring and MEMS serve to demonstrate LDV's applicability on structures of all sizes. Rotor vibrations and hearing are explored as examples of the classic applications. Applications in acoustics recognise the versatility of LDV as demonstrated by visualisation of sound fields. The paper concludes with thoughts on future developments, using examples of new multi-component and multi-channel instruments

    Large-volume optical coherence tomography with real-time correction of geometric distortion artifacts

    No full text
    Large-volume optical coherence tomography (OCT)-setups employ scanning mirrors and suffer from non-linear geometric distortion artifacts in which the degree of distortion is determined by the maximum angles over which the mirrors rotate. In this chapter, we describe a straightforward approach to correct for these distortion artifacts, creating an alternative to previously reported ray-tracing schemes that are unable to apply these corrections in real-time. By implementing the proposed 3D recalibration algorithm on the graphics card of a standard computer, this feature can be applied in real-time. We validate the accuracy of the technique using OCT measurements of a highly curved object within a large imaging volume of 12.35 x 10.13 x 2.36 mm3. The resulting 3D object shape measurements are compared against high-resolution and aberration-free optical profilometry measurements. Maintaining an optical resolution of <10μm within the sample, both axially and transversally, we realized a real-time, high-resolution, largevolume OCT imaging system, capable of producing distortion corrected wide-field OCT data with a geometric surface shape accuracy of <15μm. © 2013 Nova Science Publishers, Inc. All rights reserved

    Real-time correction of geometric distortion artefacts in large-volume optical coherence tomography

    No full text
    Large-volume optical coherence tomography (OCT) setups employ scanning mirrors and suffer from geometric distortion artefacts in which the degree of distortion is determined by the maximum angles over which the mirrors rotate. In this note, we describe a straightforward coordinate transformation scheme to correct for these artefacts in three dimensions, creating an alternative to previously reported ray-tracing schemes. We demonstrate that this recalibration procedure can be applied in real time by implementing the proposed algorithm on the graphics card of a standard computer, making it useful for topography applications. The accuracy of the proposed calibration procedure is validated over an imaging volume of 12.35x10.13x2.36 mm3 using optical moire measurements of a highly curved object. © 2013 IOP Publishing Ltd

    Full-field thickness distribution of human tympanic membrane obtained with optical coherence tomography

    No full text
    The full-field thickness distribution, three-dimensional surface model and general morphological data of six human tympanic membranes are presented. Cross-sectional images were taken perpendicular through the membranes using a high-resolution optical coherence tomography setup. Five normal membranes and one membrane containing a pathological site are included in this study. The thickness varies strongly across each membrane, and a great deal of inter-specimen variability can be seen in the measurement results, though all membranes show similar features in their respective relative thickness distributions. Mean thickness values across the pars tensa ranged between 79 and 97 μm; all membranes were thinnest in the central region between umbo and annular ring (50-70 μm), and thickness increased steeply over a small distance to approximately 100-120 μm when moving from the central region either towards the peripheral rim of the pars tensa or towards the manubrium. Furthermore, a local thickening was noticed in the antero-inferior quadrant of the membranes, and a strong linear correlation was observed between inferior-posterior length and mean thickness of the membrane. These features were combined into a single three-dimensional model to form an averaged representation of the human tympanic membrane. 3D reconstruction of the pathological tympanic membrane shows a structural atrophy with retraction pocket in the inferior portion of the pars tensa. The change of form at the pathological site of the membrane corresponds well with the decreased thickness values that can be measured there. © 2013 Association for Research in Otolaryngology
    corecore