162 research outputs found

    Dataset for multimodal fake news detection and verification tasks

    Get PDF
    The proliferation of online disinformation and fake news, particularly in the context of breaking news events, demands the development of effective detection mechanisms. While textual content remains the predominant medium for disseminating misleading information, the contribution of other modalities is increasingly emerging within online outlets and social media platforms. However, multimodal datasets, which incorporate diverse modalities such as texts and images, are not very common yet, especially in low-resource languages. This study addresses this gap by releasing a dataset tailored for multimodal fake news detection in the Italian language. This dataset was originally employed in a shared task on the Italian language. The dataset is divided into two data subsets, each corresponding to a distinct sub-task. In sub-task 1, the goal is to assess the effectiveness of multimodal fake news detection systems. Sub-task 2 aims to delve into the interplay between text and images, specifically analyzing how these modalities mutually influence the interpretation of content when distinguishing between fake and real news. Both sub-tasks were managed as classification problems. The dataset consists of social media posts and news articles. After collecting it, it was labeled via crowdsourcing. Annotators were provided with external knowledge about the topic of the news to be labeled, enhancing their ability to discriminate between fake and real news. The data subsets for sub-task 1 and sub-task 2 consist of 913 and 1350 items, respectively, encompassing newspaper articles and tweets

    Objective assessment of intraoperative skills for robot-assisted radical prostatectomy (RARP): results from the ERUS Scientific and Educational Working Groups Metrics Initiative

    Get PDF
    Objective: To develop and seek consensus from procedure experts on the metrics that best characterise a reference robot-assisted radical prostatectomy (RARP) and determine if the metrics distinguished between the objectively assessed RARP performance of experienced and novice urologists, as identifying objective performance metrics for surgical training in robotic surgery is imperative for patient safety. Materials and methods: In Study 1, the metrics, i.e. 12 phases of the procedure, 81 steps, 245 errors and 110 critical errors for a reference RARP were developed and then presented to an international Delphi panel of 19 experienced urologists. In Study 2, 12 very experienced surgeons (VES) who had performed >500 RARPs and 12 novice urology surgeons performed a RARP, which was video recorded and assessed by two experienced urologists blinded as to subject and group. Percentage agreement between experienced urologists for the Delphi meeting and Mann–Whitney U- and Kruskal–Wallis tests were used for construct validation of the newly identified RARP metrics. Results: At the Delphi panel, consensus was reached on the appropriateness of the metrics for a reference RARP. In Study 2, the results showed that the VES performed ~4% more procedure steps and made 72% fewer procedure errors than the novices (P = 0.027). Phases VIIa and VIIb (i.e. neurovascular bundle dissection) best discriminated between the VES and novices. Limitations: VES whose performance was in the bottom half of their group demonstrated considerable error variability and made five-times as many errors as the other half of the group (P = 0.006). Conclusions: The international Delphi panel reached high-level consensus on the RARP metrics that reliably distinguished between the objectively scored procedure performance of VES and novices. Reliable and valid performance metrics of RARP are imperative for effective and quality assured surgical training

    Association between metabolic syndrome, obesity, diabetes mellitus and oncological outcomes of bladder cancer. A systematic review

    Get PDF
    Metabolic syndrome is a cluster of several metabolic abnormalities, its prevalence is increasing worldwide. To summarize the most recent evidence regarding the relationship between metabolic syndrome, its components and the oncological outcomes in bladder cancer patients, a National Center for Biotechnology Information PubMed search for relevant articles either published or e-published up to March 2014 was carried out by combining the following Patient population, Intervention, Comparison, Outcome terms: metabolic syndrome, obesity, body mass index, hyperglycemia, insulin resistance, diabetes, hypertension, dyslipidemia, bladder cancer, risk, mortality, cancer specific survival, disease recurrence and progression. Metabolic syndrome is a complex, highly prevalent disorder, and central obesity, insulin resistance, dyslipidemia and hypertension are its main components. Published findings would suggest that metabolic syndrome per se might be associated with an increased risk of bladder cancer in male patients, but it did not seem to confer a risk of worse prognosis. Considering the primary components of metabolic syndrome (hypertension, obesity and dyslipidemia), available data are uncertain, and it is no possible to reach a conclusion yet on either a direct or an indirect association with bladder cancer risk and prognosis. Only with regard to type 2 diabetes mellitus, available data would suggest a potential negative correlation. However, as the evaluation of bladder cancer risk and prognosis in patients with metabolic disorders is certainly complex, further studies are urgently required to better assess the actual role of these metabolic disorders

    A DROP-IN gamma probe for robot-assisted radioguided surgery of lymph nodes during radical prostatectomy

    Get PDF
    Background: The DROP-IN gamma probe was introduced to overcome the restricted manoeuvrability of traditional laparoscopic gamma probes. Through enhanced manoeuvrability and surgical autonomy, the DROP-IN promotes the implementation of radioguided surgery in the robotic setting.Objective: To confirm the utility and safety profile of the DROP-IN gamma probe and to perform a comparison with the traditional laparoscopic gamma probe and fluorescence guidance.Design, setting, and participants: Twenty-five prostate cancer patients were scheduled for a robot-assisted sentinel lymph node (SN) procedure, extended pelvic lymph node dissection, and prostatectomy at a single European centre.Surgical procedure: After intraprostatic injection of indocyanine green (ICG)-Tc-99m-nanocolloid (n = 12) or Tc-99m-nanocolloid + ICG (n = 13), SN locations were defined using preoperative imaging. Surgical excision of SNs was performed under image guidance using the DROP-IN gamma probe, the traditional laparoscopic gamma probe, and fluorescence imaging.Measurements: Intraoperative SN detection was assessed for the different modalities and related to anatomical locations. Patient follow-up was included (a median of 18 mo).Results and limitations: Overall, 47 SNs were pursued in vivo by the DROP-IN gamma probe, of which 100% were identified. No adverse events related to its use were observed. In vivo fluorescence imaging identified 91% of these SNs. The laparoscopic gamma probe identified only 76% of these SNs, where the detection inaccuracies appeared to be related to specific anatomical regions.Conclusions: Owing to improved manoeuvrability, the DROP-IN probe yielded improved SN detection rates compared with the traditional gamma probe and fluorescence imaging. These findings underline that the DROP-IN technology provides a valuable tool for radioguided surgery in the robotic setting.Patient summary: Radioguided robot-assisted surgery with the novel DROP-IN gamma probe is feasible and safe. It enables more efficient intraoperative identification of sentinel lymph nodes than can be achieved with a traditional laparoscopic gamma probe. The use of the DROP-IN probe in combination with fluorescence imaging allows for a complementary optical confirmation of node localisations. (C) 2020 The Author(s). Published by Elsevier B.V. on behalf of European Association of Urology.Oncologic Imagin

    Diagnostic value, oncologic outcomes, and safety profile of image-guided surgery technologies during robot-assisted lymph node dissection with sentinel node biopsy for prostate cancer

    Get PDF
    Despite good sensitivity and a good negative predictive value, the implementation of sentinel node biopsy (SNB) in robot-assisted radical prostatectomy with extended pelvic lymph node dissection (ePLND) for prostate cancer is still controversial. For this reason, we aimed to define the added value of SNB (with different tracer modalities) to ePLND in the identification of nodal metastases. Complication rates and oncologic outcomes were also assessed. Methods: From January 2006 to December 2019, prospectively collected data were retrospectively analyzed from a single-institution database regarding prostate cancer patients treated with robot-assisted radical prostatectomy and ePLND with or without additional use of SNB, either with the hybrid tracer indocyanine green (ICG)-Tc-99m-nanocolloid or with free ICG. Multivariable logistic and Cox regression models tested the impact of adding SNB (either with the hybrid tracer or with free ICG) on lymph nodal invasion detection, complications, and oncologic outcomes. Results: Overall, 1,680 patients were included in the final analysis: 1,168 (69.5%) in the non-SNB group, 161 (9.6%) in the ICG-SNB group, and 351 (20.9%) in the hybrid-SNB group. The hybrid-SNB group (odds ratio, 1.61; 95%CI, 1.18-2.20; P = 0.002) was an independent predictor of nodal involvement, whereas the ICG-SNB group did not reach independent predictor status when compared with the non-SNB group (odds ratio, 1.35; 95%CI, 0.89-2.03; P = 0.1). SNB techniques were not associated with higher rates of complications. Lastly, use of hybrid SNB was associated with lower rates of biochemical recurrence (0.79; 95%CI, 0.63-0.98) and of clinical recurrence (hazard ratio, 0.76, P = 0.035) than were seen in the non-SNB group. Conclusion: The implementation of hybrid-SNB technique with ICG-Tc-99m-nanocolloid in prostate cancer improves detection of positive nodes and potentially lowers recurrence rates with subsequent optimization of patient management, without harming patient safety.Imaging- and therapeutic targets in neoplastic and musculoskeletal inflammatory diseas

    Assessing the clinical value of positive multiparametric magnetic resonance imaging in young men with a suspicion of prostate cancer

    Get PDF
    Background: There is a lack of evidence on the ability of magnetic resonance imaging (MRI) of the prostate to detect clinically significant prostate cancer (csPCa) in young patients.Objective: We hypothesised that the diagnostic performance of MRI for csPCa varies according to patient's age. To address this, we assessed the variation in the csPCa detection rate of MRI targeted biopsy (MRI-TBx) versus systematic random biopsy (SBx) across different patient ages.Design, setting, and participants: We retrospectively identified 930 patients who underwent prostate MRI and subsequent biopsy at two referral centres between 2013 and 2018. The Prostate Imaging Reporting and Data System (PI-RADS) was used for MRI reporting.Intervention: A lesion with a PI-RADS score of >= 3 detected at MRI received an MRI-TBx in addition to an SBx during the same session.Outcome measurements and statistical analysis: The outcome of our study was the relationship between age and csPCa detection rate at MRI-TBx and SBx, respectively. Clinically significant prostate cancer (PCa) was defined as the presence of PCa with Gleason score >= 3 + 4. Multivariable logistic regression analyses (MVAs) predicting csPCa detection were assessed for both MRI-TBx and SBx. Covariates were age, prostate-specific antigen density, PI-RADS score, previous biopsy status, digital rectal examination, and the number of targeted and systematic cores. The hypothesis that MRI accuracy in detecting csPCa differed by age was finally tested with a nonparametric loess analysis.Results and limitations: The overall rate of csPCa was 54% (n = 506). Overall, 325 (35%) and 461 (50%) patients had csPCa at SBx and MRI-TBx, respectively. The median numbers of SBx and MRI-TBx cores were 12 (interquartile range [IQR]: 10-13) and 5 (IQR: 4-7), respectively. At MVA, age at biopsy was an independent predictor of csPCa at MRI-TBx only (odds ratio: 1.05), after accounting for confounders. In men aged less than roughly 50 yr, SBx had a higher probability of detecting csPCa relative to MRI-TBx (25% vs 16% at 40 yr). Conversely, in patients aged >50 yr, the probability of csPCa was higher in MRI-TBx than in SBx, reaching the highest difference for very elderly patients (48% vs 68% at 80 yr). The main limitations were the retrospective design and the small number of young patients.Conclusions: In this study, we reported the performance of MRI and MRI-TBx in detecting csPCa changes according to patients' age.Patient summary: In young patients, the performance of a systematic random biopsy in detecting clinically significant prostate cancer (csPCa) is higher relative to magnetic resonance imaging targeted biopsy (MRI-TBx), reflecting the lower accuracy of MRI in younger men. Conversely, in older patients, MRI-TBx showed a clinical benefit with a higher csPCa detection rate compared with SBx, suggesting an increase of MRI accuracy with the increase of age. (C) 2019 European Association of Urology. Published by Elsevier B.V. All rights reserved.</p

    A predictive preoperative and postoperative nomogram for postoperative potency recovery after robot-assisted radical prostatectomy

    Get PDF
    Purpose: Prediction of potency recovery following robot-assisted radical prostatectomy (RARP) is useful for better patient counseling and postoperative treatment strategies. In this study we propose a preoperative and postoperative nomogram to predict postoperative potency recovery following RARP.Materials and Methods: Patients from development set (6,502) were selected to develop the nomograms, and patients in validation set (2,706) were used for validation. Cox regression models were fitted on the development cohort to predict potency recovery after RARP using as prognostic factors the covariates selected. Two nomograms were drawn using the regression coefficients of the preoperative and postoperative Cox models.Results: The discrimination ability of the preoperative model was evaluated on the development cohort using the receiver operator curves estimated at 3, 6, 12 and 24 months. The AUC at these time points was 0.726, 0.734, 0.754, and 0.778, respectively. The areas under the curve of the postoperative model at 3, 6, 12 and 24 months were 0.746, 0.756 and 0.777, and 0.801, respectively. Preoperative and postoperative predictive models were validated using a separate set of 2,706 patients. The AUCs of the preoperative model at 3, 6, 12 and 24 months were 0.789, 0.772, 0.768, and 0.778, respectively. The ROC curves of the postoperative model at 3, 6, 12 and 24 months with AUCs of 0.807, 0.797, 0.793 and 0.798, respectively. Along with age and preoperative sexual function, nerve-sparing technique determines the potency outcomes justifying better AUC for postoperative model vs the preoperative model.Conclusions: The above nomograms help us to predict with good accuracy the probability of potency recovery within 3, 6, 12 and 24 months following surgery taking into consideration preoperative and postoperative factors. This is a novel tool for the care giver to predict realistic expectation of potency outcomes to the patients, while preoperative and immediate postoperative counseling

    The Click-On gamma probe, a second-generation tethered robotic gamma probe that improves dexterity and surgical decision-making

    Get PDF
    Purpose Decision-making and dexterity, features that become increasingly relevant in (robot-assisted) minimally invasive surgery, are considered key components in improving the surgical accuracy. Recently, DROP-IN gamma probes were introduced to facilitate radioguided robotic surgery. We now studied if robotic DROP-IN radioguidance can be further improved using tethered Click-On designs that integrate gamma detection onto the robotic instruments themselves. Methods Using computer-assisted drawing software, 3D printing and precision machining, we created a Click-On probe containing two press-fit connections and an additional grasping moiety for a ProGrasp instrument combined with fiducials that could be video tracked using the Firefly laparoscope. Using a dexterity phantom, the duration of the specific tasks and the path traveled could be compared between use of the Click-On or DROP-IN probe. To study the impact on surgical decision-making, we performed a blinded study, in porcine models, wherein surgeons had to identify a hidden Co-57-source using either palpation or Click-On radioguidance. Results When assembled onto a ProGrasp instrument, while preserving grasping function and rotational freedom, the fully functional prototype could be inserted through a 12-mm trocar. In dexterity assessments, the Click-On provided a 40% reduction in movements compared to the DROP-IN, which converted into a reduction in time, path length, and increase in straightness index. Radioguidance also improved decision-making; task-completion rate increased by 60%, procedural time was reduced, and movements became more focused. Conclusion The Click-On gamma probe provides a step toward full integration of radioguidance in minimal invasive surgery. The value of this concept was underlined by its impact on surgical dexterity and decision-making.Imaging- and therapeutic targets in neoplastic and musculoskeletal inflammatory diseas

    Applicability of COVID-19 Pandemic recommendations for urology practice: data from three major Italian hot spots (BreBeMi)

    Get PDF
    Background: Lombardy has been the first and one of the most affected European regions during the first and second waves of the novel coronavirus (severe acute respiratory syndrome coronavirus 2 [SARS-CoV-2]).Objective: To evaluate the impact of coronavirus disease 2019 (COVID-19) on all urologic activities over a 17-wk period in the three largest public hospitals in Lombardy located in the worst hit area in Italy, and to assess the applicability of the authorities' recommendations provided for reorganising urology practice.Design, setting, and participants: A retrospective analysis of all urologic activities performed at three major public hospitals in Lombardy (Brescia, Bergamo, and Milan), from January 1 to April 28, 2020, was performed.Outcome measurements and statistical analysis: Join-point regression was used to identify significant changes in trends for all urologic activities. Average weekly percentage changes (AWPCs) were estimated to summarise linear trends. Uro-oncologic surgeries performed during the pandemic were tabulated and stratified according to the first preliminary recommendations by Stensland et al (Stensland KD, Morgan TM, Moinzadeh A, et al. Considerations in the triage of urologic surgeries during the COVID-19 pandemic. Eur Urol 2020;77:663-6) and according to the level of priority recommended by European Association of Urology guidelines.Results and limitations: The trend for 2020 urologic activities decreased constantly from weeks 8-9 up to weeks 11-13 (AWPC range -41%, -29.9%; p < 0.001). One-third of uro-oncologic surgeries performed were treatments that could have been postponed, according to the preliminary urologic recommendations. High applicability to recommendations was observed for non-muscle-invasive bladder cancer (NMIBC) patients with intermediate/emergency level of priority, penile and testicular cancer patients, and upper tract urothelial cell carcinoma (UTUC) and renal cell carcinoma (RCC) patients with intermediate level of priority. Low applicability was observed for NMIBC patients with low/high level of priority, UTUC patients with high level of priority, prostate cancer patients with intermediate/high level of priority, and RCC patients with low level of priority.Conclusions: During COVID-19, we found a reduction in all urologic activities. High-priority surgeries and timing of treatment recommended by the authorities require adaptation according to hospital resources and local incidence.Patient summary: We assessed the urologic surgeries that were privileged during the first wave of coronavirus disease 2019 (COVID-19) in the three largest public hospitals in Lombardy, worst hit by the pandemic, to evaluate whether high-priority surgeries and timing of treatment recommended by the authorities are applicable. Pandemic recommendations provided by experts should be tailored according to hospital capacity and different levels of the pandemic. (C) 2021 The Author(s). Published by Elsevier B.V. on behalf of European Association of Urology

    Systematic Review of Active Surveillance for Clinically Localised Prostate Cancer to Develop Recommendations Regarding Inclusion of Intermediate-risk Disease, Biopsy Characteristics at Inclusion and Monitoring, and Surveillance Repeat Biopsy Strategy

    Get PDF
    none38siContext: There is uncertainty regarding the most appropriate criteria for recruitment, monitoring, and reclassification in active surveillance (AS) protocols for localised prostate cancer (PCa). Objective: To perform a qualitative systematic review (SR) to issue recommendations regarding inclusion of intermediate-risk disease, biopsy characteristics at inclusion and monitoring, and repeat biopsy strategy. Evidence acquisition: A protocol-driven, Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA)-adhering SR incorporating AS protocols published from January 1990 to October 2020 was performed. The main outcomes were criteria for inclusion of intermediate-risk disease, monitoring, reclassification, and repeat biopsy strategies (per protocol and/or triggered). Clinical effectiveness data were not assessed. Evidence synthesis: Of the 17 011 articles identified, 333 studies incorporating 375 AS protocols, recruiting 264 852 patients, were included. Only a minority of protocols included the use of magnetic resonance imaging (MRI) for recruitment (n = 17), follow-up (n = 47), and reclassification (n = 26). More than 50% of protocols included patients with intermediate or high-risk disease, whilst 44.1% of protocols excluded low-risk patients with more than three positive cores, and 39% of protocols excluded patients with core involvement (CI) >50% per core. Of the protocols, ≥80% mandated a confirmatory transrectal ultrasound biopsy; 72% (n = 189) of protocols mandated per-protocol repeat biopsies, with 20% performing this annually and 25% every 2 yr. Only 27 protocols (10.3%) mandated triggered biopsies, with 74% of these protocols defining progression or changes on MRI as triggers for repeat biopsy. Conclusions: For AS protocols in which the use of MRI is not mandatory or absent, we recommend the following: (1) AS can be considered in patients with low-volume International Society of Urological Pathology (ISUP) grade 2 (three or fewer positive cores and cancer involvement ≤50% CI per core) or another single element of intermediate-risk disease, and patients with ISUP 3 should be excluded; (2) per-protocol confirmatory prostate biopsies should be performed within 2 yr, and per-protocol surveillance repeat biopsies should be performed at least once every 3 yr for the first 10 yr; and (3) for patients with low-volume, low-risk disease at recruitment, if repeat systematic biopsies reveal more than three positive cores or maximum CI >50% per core, they should be monitored closely for evidence of adverse features (eg, upgrading); patients with ISUP 2 disease with increased core positivity and/or CI to similar thresholds should be reclassified. Patient summary: We examined the literature to issue new recommendations on active surveillance (AS) for managing localised prostate cancer. The recommendations include setting criteria for including men with more aggressive disease (intermediate-risk disease), setting thresholds for close monitoring of men with low-risk but more extensive disease, and determining when to perform repeat biopsies (within 2 yr and 3 yearly thereafter).noneWillemse, Peter-Paul M; Davis, Niall F; Grivas, Nikolaos; Zattoni, Fabio; Lardas, Michael; Briers, Erik; Cumberbatch, Marcus G; De Santis, Maria; Dell'Oglio, Paolo; Donaldson, James F; Fossati, Nicola; Gandaglia, Giorgio; Gillessen, Silke; Grummet, Jeremy P; Henry, Ann M; Liew, Matthew; MacLennan, Steven; Mason, Malcolm D; Moris, Lisa; Plass, Karin; O'Hanlon, Shane; Omar, Muhammad Imran; Oprea-Lager, Daniela E; Pang, Karl H; Paterson, Catherine C; Ploussard, Guillaume; Rouvière, Olivier; Schoots, Ivo G; Tilki, Derya; van den Bergh, Roderick C N; Van den Broeck, Thomas; van der Kwast, Theodorus H; van der Poel, Henk G; Wiegel, Thomas; Yuan, Cathy Yuhong; Cornford, Philip; Mottet, Nicolas; Lam, Thomas B LWillemse, Peter-Paul M; Davis, Niall F; Grivas, Nikolaos; Zattoni, Fabio; Lardas, Michael; Briers, Erik; Cumberbatch, Marcus G; De Santis, Maria; Dell'Oglio, Paolo; Donaldson, James F; Fossati, Nicola; Gandaglia, Giorgio; Gillessen, Silke; Grummet, Jeremy P; Henry, Ann M; Liew, Matthew; Maclennan, Steven; Mason, Malcolm D; Moris, Lisa; Plass, Karin; O'Hanlon, Shane; Omar, Muhammad Imran; Oprea-Lager, Daniela E; Pang, Karl H; Paterson, Catherine C; Ploussard, Guillaume; Rouvière, Olivier; Schoots, Ivo G; Tilki, Derya; van den Bergh, Roderick C N; Van den Broeck, Thomas; van der Kwast, Theodorus H; van der Poel, Henk G; Wiegel, Thomas; Yuan, Cathy Yuhong; Cornford, Philip; Mottet, Nicolas; Lam, Thomas B
    corecore