2,804 research outputs found
Measuring Propagation Speed of Coulomb Fields
The problem of gravity propagation has been subject of discussion for quite a
long time: Newton, Laplace and, in relatively more modern times, Eddington
pointed out that, if gravity propagated with finite velocity, planets motion
around the sun would become unstable due to a torque originating from time lag
of the gravitational interactions.
Such an odd behavior can be found also in electromagnetism, when one computes
the propagation of the electric fields generated by a set of uniformly moving
charges. As a matter of fact the Li\'enard-Weichert retarded potential leads to
a formula indistinguishable from the one obtained assuming that the electric
field propagates with infinite velocity. Feyman explanation for this apparent
paradox was based on the fact that uniform motions last indefinitely.
To verify such an explanation, we performed an experiment to measure the
time/space evolution of the electric field generated by an uniformely moving
electron beam. The results we obtain on such a finite lifetime kinematical
state seem compatible with an electric field rigidly carried by the beam
itself.Comment: 23 pages, 15 figure
Beam test of scintillation tiles with MPPC readout
This paper describes measurements made using counters composed of a small (3 by 3 by 0.5 cm3) scintillation tile coupled to a Multi-Photon Pixel Counter (MPPC) produced by Hamamatsu and exposed to an electron beam at the Beam Test Facility in Frascati. We show our first results for charge spectra and efficiency, and a very preliminary measurement of device linearity
A new concept for streamer quenching in resistive plate chambers
In this paper we propose a new concept for streamer quenching in Resistive Plate Chambers (RPCs). In our approach, the multiplication process is quenched by the appropriate design of a mechanical structure inserted between the two resistive electrodes. We show that stable performance is achieved with binary gas mixtures based on argon and a small fraction of isobutane. Fluorocarbons, deemed responsible for the degradation of the electrode inner surface of RPC detectors, are thus fully eliminated from the gas mixture. This design {also resulted} in a simplified assembly procedure. Preliminary results obtained with a few prototypes of ``Mechanically Quenched RPCs'' and some prospects for future developments are discussed
Characterization and Performance of PADME's Cherenkov-Based Small-Angle Calorimeter
The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in
Italy, will search for invisible decays of the hypothetical dark photon via the
process , where the escapes detection. The
dark photon mass range sensitivity in a first phase will be 1 to 24 MeV. We
report here on measurement and simulation studies of the performance of the
Small-Angle Calorimeter, a component of PADME's detector dedicated to rejecting
2- and 3-gamma backgrounds. The crucial requirement is a timing resolution of
less than 200 ps, which is satisfied by the choice of PbF crystals and the
newly released Hamamatsu R13478UV photomultiplier tubes (PMTs). We find a
timing resolution of 81 ps (with double-peak separation resolution of 1.8 ns)
and a single-crystal energy resolution of 5.7%/ with light yield of
2.07 photo-electrons per MeV, using 100 to 400 MeV electrons at the Beam Test
Facility of LNF. We also propose the investigation of a two-PMT solution
coupled to a single PbF crystal for higher-energy applications, which has
potentially attractive features.Comment: 12 pages, 19 figures. v2: added section on radiation damage studie
Biocompatibility, Inflammatory Response, and Recannalization Characteristics of Nonradioactive Resin Microspheres: Histological Findings
Intra-arterial radiotherapy with yttrium-90 microspheres (radioembolization) is a therapeutic procedure exclusively applied to the liver that allows the direct delivery of high-dose radiation to liver tumors, by means of endovascular catheters, selectively placed within the tumor vasculature. The aim of the study was to describe the distribution of spheres within the precapillaries, inflammatory response, and recannalization characteristics after embolization with nonradioactive resin microspheres in the kidney and liver. We performed a partial embolization of the liver and kidney vessels in nine white pigs. The left renal and left hepatic arteries were catheterized and filled with nonradioactive resin microspheres. Embolization was defined as the initiation of near-stasis of blood flow, rather than total occlusion of the vessels. The hepatic circulation was not isolated so that the effects of reflux of microspheres into stomach could be observed. Animals were sacrificed at 48 h, 4 weeks, and 8 weeks, and tissue samples from the kidney, liver, lung, and stomach evaluated. Microscopic evaluation revealed clusters of 10–30 microspheres (15–30 μm in diameter) in the small vessels of the kidney (the arciform arteries, vasa recti, and glomerular afferent vessels) and liver. Aggregates were associated with focal ischemia and mild vascular wall damage. Occlusion of the small vessels was associated with a mild perivascular inflammatory reaction. After filling of the left hepatic artery with microspheres, there was some evidence of arteriovenous shunting into the lungs, and one case of cholecystitis and one case of marked gastritis and ulceration at the site of arterial occlusion due to the presence of clusters of microspheres. Beyond 48 h, microspheres were progressively integrated into the vascular wall by phagocytosis and the lumen recannalized. Eight-week evaluation found that the perivascular inflammatory reaction was mild. Liver cell damage, bile duct injury, and portal space fibrosis were not observed. In conclusion, resin microspheres (15–30 μm diameter) trigger virtually no inflammatory response in target tissues (liver and kidney). Clusters rather than individual microspheres were associated with a mild to moderate perivascular inflammatory reaction. There was no evidence of either a prolonged inflammatory reaction or fibrosis in the liver parenchyma following recannalization
Test of large area glass RPCs at the DA Phi NE Test Beam Facility (BTF)
Abstract The CaPiRe program has been started to develop a new detector design, in order to produce large areas of glass Resistive Plate Chambers (RPC) detectors, overcoming the previous limitations. As a first step we produced our glass RPC detectors ( 1 m 2 ) at General Tecnica exploiting their standard procedures, materials and production techniques simply using 2 mm glass electrodes instead of the bakelite ones. A set of RPC was produced by using pre-coated (silk screen printed) electrodes, while others were produced with the standard graphite coating. All the detectors, together with four old Glass RPC acting as reference, were tested at the DA Φ NE Test Beam Facility with 500 MeV electrons in order to study the efficiency in different positions inside the detectors (i.e. near spacers and edges) and to study the detector behavior as a function of the local particle rate
Gastroduodenal injury after radioembolization of hepatic tumors
Radioembolization is a new tool for the treatment of hepatic tumors
that consists in the injection of biocompatible microspheres carrying
radioisotopes into the hepatic artery or its branches. METHODS: We have performed
radioembolization in 78 patients with hepatic tumors using resin-based
microspheres loaded with yttrium-90. All patients were previously evaluated to
minimize the risk of hazardous irradiation to nontarget organs and to obtain the
data needed for dose calculation. RESULTS: We report a complication found in
three cases (3.8%) that consists of abdominal pain resulting from gastroduodenal
lesions and that had a chronic, insidious course. Microscopically, microspheres
were detected in the specimens obtained from all affected gastric areas. Since
these gastroduodenal lesions do not appear when nonradiating microspheres are
injected in animals, lesions are likely to be due to radiation and not to an
ischemic effect of vascular occlusion by spheres. CONCLUSIONS: We believe that a
pretreatment evaluation that includes a more thorough scrutiny of the hepatic
vascularization in search of small collaterals connecting to the gastroduodenal
tract can help prevent this awkward complicatio
Measurement of the branching ratios of the Z0 into heavy quarks
We measure the hadronic branching ratios of the Z0 boson into heavy quarks:
Rb=Gamma(Z0->bb)/Gamma(Z0->hadrons) and Rc=Gamma(Z0->cc/Gamma(Z0->hadrons)
using a multi-tag technique. The measurement was performed using about 400,000
hadronic Z0 events recorded in the SLD experiment at SLAC between 1996 and
1998. The small and stable SLC beam spot and the CCD-based vertex detector were
used to reconstruct bottom and charm hadron decay vertices with high efficiency
and purity, which enables us to measure most efficiencies from data. We obtain,
Rb=0.21604 +- 0.00098(stat.) +- 0.00073(syst.) -+ 0.00012(Rc) and, Rc= 0.1744
+- 0.0031(stat.) +- 0.0020(syst.) -+ 0.0006(Rb)Comment: 37 pages, 8 figures, to be submitted to Phys. Rev. D version 2:
changed title to ratios, used common D production fractions for Rb and Rc and
corrected Zgamma interference. Identical to PRD submissio
Direct Measurements of A_b and A_c using Vertex/Kaon Charge Tags at SLD
Exploiting the manipulation of the SLC electron-beam polarization, we present
precise direct measurements of the parity violation parameters A_c and A_b in
the Z boson - c quark and Z boson - b quark coupling. Quark/antiquark
discrimination is accomplished via a unique algorithm that takes advantage of
the precise SLD CCD vertex detector, employing the net charge of displaced
vertices as well as the charge of kaons that emanate from those vertices. From
the 1996-98 sample of 400,000 Z decays, produced with an average beam
polarization of 73.4%, we find A_c = 0.673 +/- 0.029 (stat.) +/- 0.023 (syst.)
and A_b = 0.919 +/- 0.018 (stat.) +/- 0.017 (syst.).Comment: 11 pages, 2 figures, 2 tables, to be submitted to Physical Review
Letters; version 2 reflects changes suggested by the refere
- …