163 research outputs found

    A method for calculating 16o/18o peptide ion ratios for the relative quantification of proteomes

    Get PDF
    AbstractA method is described for the identification and relative quantification of proteomes using accurate mass tags (AMT) generated by nLC-dual ESI-FT-ICR-MS on a 7T instrument in conjunction with stable isotope labeling using 16O/18O ratios. AMTs were used for putative peptide identification, followed by confirmation of peptide identity by tandem mass spectrometry. For a combined set of 58 tryptic peptides from bovine serum albumin (BSA) and human transferrin, a mean mass measurement accuracy of 1.9 ppm ±0.94 ppm (CIM99%) was obtained. This subset of tryptic peptides was used to measure 16O/18O ratios of 0.36 ± 0.09 (CIM99%) for BSA (μ = 0.33) and 1.48 ± 0.47 (CIM99%) for transferrin (μ = 1.0) using a method for calculating 16O/18O ratios from overlapping isotopic multiplets arising from mixtures of 16O, 18O1, and 18O2 labeled C-termini. The model amino acid averagine was used to calculate a representative molecular formula for estimating and subtracting the contributions of naturally occurring isotopes solely as a function of peptide molecular weight. The method was tested against simulated composite 16O/18O spectra where peptide molecular weight, 16O/18O ratio, 18O1/18O2 ratios, and number of sulfur atoms were varied. Relative errors of 20% or less were incurred when the 16O/18O ratios were less than three, even for peptides where the number of sulfur atoms was over- or under-estimated. These data demonstrate that for biomarker discovery, it is advantageous to label the proteome representing the disease state with 18O; and the method is not sensitive to variations in 18O1/18O2 ratio. This approach allows a comprehensive differentiation of expression levels and tentative identification via AMTs, followed by targeted analysis of over- and under-expressed peptides using tandem mass spectrometry, for applications such as the discovery of disease biomarkers

    Intact and Top-Down Characterization of Biomolecules and Direct Analysis Using Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Coupled to FT-ICR Mass Spectrometry

    Get PDF
    We report the implementation of an infrared laser onto our previously reported matrix-assisted laser desorption electrospray ionization (MALDESI) source with ESI post-ionization yielding multiply charged peptides and proteins. Infrared (IR)-MALDESI is demonstrated for atmospheric pressure desorption and ionization of biological molecules ranging in molecular weight from 1.2 to 17 kDa. High resolving power, high mass accuracy single-acquisition Fourier transform ion cyclotron resonance (FT-ICR) mass spectra were generated from liquid- and solid-state peptide and protein samples by desorption with an infrared laser (2.94 μm) followed by ESI post-ionization. Intact and top-down analysis of equine myoglobin (17 kDa) desorbed from the solid state with ESI post-ionization demonstrates the sequencing capabilities using IR-MALDESI coupled to FT-ICR mass spectrometry. Carbohydrates and lipids were detected through direct analysis of milk and egg yolk using both UV- and IR-MALDESI with minimal sample preparation. Three of the four classes of biological macromolecules (proteins, carbohydrates, and lipids) have been ionized and detected using MALDESI with minimal sample preparation. Sequencing of O-linked glycans, cleaved from mucin using reductive β-elimination chemistry, is also demonstrated. © 2009 American Society for Mass Spectrometry

    Quantitative Top-Down Proteomics of SILAC Labeled Human Embryonic Stem Cells

    Get PDF
    Human embryonic stem cells (hESCs) are self-renewing pluripotent cells with relevance to treatment of numerous medical conditions. However, a global understanding of the role of the hESC proteome in maintaining pluripotency or triggering differentiation is still largely lacking. The emergence of top-down proteomics has facilitated the identification and characterization of intact protein forms that are not readily apparent in bottom-up studies. Combined with metabolic labeling techniques such as stable isotope labeling by amino acids in cell culture (SILAC), quantitative comparison of intact protein expression under differing experimental conditions is possible. Herein, quantitative top-down proteomics of hESCs is demonstrated using the SILAC method and nano-flow reverse phase chromatography directly coupled to a linear-ion-trap Fourier transform ion cyclotron resonance mass spectrometer (nLC-LTQ-FT-ICR-MS). In this study, which to the best of our knowledge represents the first top-down analysis of hESCs, we have confidently identified 11 proteins by accurate intact mass, MS/MS, and amino acid counting facilitated by SILAC labeling. Although quantification is challenging due to the incorporation of multiple labeled amino acids (i.e., lysine and arginine) and arginine to proline conversion, we are able to quantitatively account for these phenomena using a mathematical model

    Naturally processed measles virus peptide eluted from class II HLA-DRB1*03 recognized by T lymphocytes from human blood

    Get PDF
    AbstractThis is the first report of the direct identification of a HLA-DRB1*03 measles-derived peptide from measles virus infected EBV-transformed B cells. We purified HLA-DR3-peptide complexes from EBV-B cells infected with measles virus (Edmonston strain) and sequenced the HLA-DR3-peptides by mass spectrometry. A class II peptide, derived from a measles phosphoprotein, ASDVETAEGGEIHELLRLQ (P1, residues 179–197), exhibited the capacity to stimulate peripheral blood mononuclear cells to proliferate. Our data provides direct evidence that the antigenic peptide of measles virus was processed by antigen-presenting cells, presented in the context of HLA class II molecules, and was recognized by peripheral blood T cells from healthy individuals previously immunized with measles vaccine. The approach described herein provides a useful methodology for the future identification of HLA-presented pathogen-derived epitopes using mass spectrometry. The study of cell-mediated immune responses to the measles-derived peptide in immune persons should provide significant insight into the design and development of new vaccines

    Quantitative mass spectrometry imaging of emtricitabine in cervical tissue model using infrared matrix-assisted laser desorption electrospray ionization

    Get PDF
    A quantitative mass spectrometry imaging (QMSI) technique using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is demonstrated for the antiretroviral (ARV) drug emtricitabine in incubated human cervical tissue. Method development of the QMSI technique leads to a gain in sensitivity and removal of interferences for several ARV drugs. Analyte response was significantly improved by a detailed evaluation of several cationization agents. Increased sensitivity and removal of an isobaric interference was demonstrated with sodium chloride in the electrospray solvent. Voxel-to-voxel variability was improved for the MSI experiments by normalizing analyte abundance to a uniformly applied compound with similar characteristics to the drug of interest. Finally, emtricitabine was quantified in tissue with a calibration curve generated from the stable isotope-labeled analog of emtricitabine followed by cross-validation using liquid chromatography tandem mass spectrometry (LC-MS/MS). The quantitative IR-MALDESI analysis proved to be reproducible with an emtricitabine concentration of 17.2±1.8 μg/gtissue. This amount corresponds to the detection of 7 fmol/voxel in the IR-MALDESI QMSI experiment. Adjacent tissue slices were analyzed using LC-MS/MS which resulted in an emtricitabine concentration of 28.4±2.8 μg/gtissue

    Discovery of ovarian cancer biomarkers in serum using NanoLC electrospray ionization TOF and FT-ICR mass spectrometry

    Get PDF
    Abstract. Treatment of cancer patients is greatly facilitated by detection of the cancer prior to metastasis. One of the obstacles to early cancer detection is the lack of availability of biomarkers with sufficient specificity. With modern differential proteomic techniques, the potential exists to identify high specificity cancer biomarkers. We have delineated a set of protocols for the isolation and identification of serum biomarkers for ovarian cancer that exist in the low molecular weight serum fraction. After isolation of the low molecular weight fraction by ultrafiltration, the potential biomarkers are separated by reversed phase nano liquid chromatography. Detection via TOF or FT-ICR yields a data set for each sample. We compared stage III/IV ovarian cancer serum with postmenopausal age-matched controls. Using bioinformatics tools developed at Mayo, we normalized each sample for intensity and chromatographic alignment. Normalized data sets are subsequently compared and potential biomarkers identified. Several candidate biomarkers were found. One of these contains the sequence of fibrinopeptide-A known to be elevated in many types of cancer including ovarian cancer. The protocols utilized will be examined and would be applicable to a wide variety of cancers or disease states

    Mapping Antiretroviral Drugs in Tissue by IR-MALDESI MSI Coupled to the Q Exactive and Comparison with LC-MS/MS SRM Assay

    Get PDF
    This work describes the coupling of the IR-MALDESI imaging source with the Q Exactive mass spectrometer. IR-MALDESI MSI was used to elucidate the spatial distribution of several HIV drugs in cervical tissues that had been incubated in either a low or high concentration. Serial sections to those analyzed by IR-MALDESI MSI were homogenized and analyzed by LC-MS/MS to quantify the amount of each drug present in the tissue. By comparing the two techniques, an agreement between the average intensities from the imaging experiment with the absolute quantities for each drug was observed. This correlation between these two techniques serves as a prerequisite to quantitative IR-MALDESI MSI. In addition, a targeted MS2 imaging experiment was also conducted to demonstrate the capabilities of the Q Exactive and to highlight the added selectivity that can be obtained with SRM or MRM imaging experiments

    Sistem Kontrol Kekeruhan dan Temperatur Air Laut Menggunakan Microcontroller Arduino Mega

    Full text link
    Sistem kontrol merupakan bagian yang tidak dapat dipisahkan dalam kehidupan sehari-hari.. Saat ini penerapan sistem kontrol telah menjamah bidang perkebunan, perikanan ataupun pertanian. Dalam penelitian ini, sistem kontrol akan diterapkan pada proses budidaya perikanan seperti budidaya ikan kerapu. Dimana ikan kerapu memiliki habitat dengan kondisi air laut dengan kadar garam 30 - 33 ppt, kadar oksigen ± 4 ppm, temperatur air laut 240 - 310C dan kadar keasaman (pH) air laut 7,6 - 7,8. Kecepatan arus air ideal sekitar 20 hingga 40 cm/detik dimana diperlukan untuk pergantian air dan oksigen serta untuk mengalirkan sisa metabolisme ikan serta pakan ikan keluar. Kondisi habitat ikan ini harus dpat dikontrol dengan baik. Di beberapa tempat budidaya ikan kerapu sistem penjagaan kondisi habitat ini dilakukan secara manual. Dengan adanya sistem kontrol, kondisi habitat ini akan sangat mudah dijaga. Dimana dalam penelitian ini difokuskan pada kemampuan sistem kontrol kekeruhan dan temperatur air laut meliputi fungsi sensor, waktu kerja pengontrol dan kinerja peralatan kontrol. Perangkat pengontrol menggunakan microcontroller Arduino Mega dengan beberapa sensor temperatur dan kekeruhan. Sensor temperatur menggunakan tipe DS18S20 dan untuk kontrol kekeruhan menggunakan sensor turbidity. Dari hasil pengujian didapatkan bahwa sistem kontrol ini dapat mengatur dan menjaga kadar kekeruhan dan temperatur air laut dengan arus 0.215 A untuk satu relay dan 0.33 A untuk 3 relay. Untuk kekeruhan dibutuhkan waktu yang dibutuhkan untuk kontrol aktif yaitu 15 detik dengan indikator kekeruhan dari pakan ikan sebanyak 50 gram dan 10 liter air. Untuk kapasitas yang lain 15 liter air didapatkan waktu kontrol aktif pada 40 detik dengan jumlah pakan 50 gram. Hal ini menunjukkan kontrol kekeruhan bekerja dengan baik dengan semakin keruh air laut semakin cepat bekerja sistem kontrol menggantikan air laut untuk tetap menjaga habitatnya. Waktu yang dibutuhkan untuk menurukan temperatur 1.270C adalah 6 menit 37 detik dengan kapasitas 10 lite

    Mass Spectrometry Imaging Reveals Heterogeneous Efavirenz Distribution within Putative HIV Reservoirs

    Get PDF
    ABSTRACT Persistent HIV replication within active viral reservoirs may be caused by inadequate antiretroviral penetration. Here, we used mass spectrometry imaging with infrared matrix-assisted laser desorption–electrospray ionization to quantify the distribution of efavirenz within tissues from a macaque dosed orally to a steady state. Intratissue efavirenz distribution was heterogeneous, with the drug concentrating in the lamina propria of the colon, the primary follicles of lymph nodes, and the brain gray matter. These are the first imaging data of an antiretroviral drug in active viral reservoirs

    Identification of alternative splice variants in Aspergillus flavus through comparison of multiple tandem MS search algorithms

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Database searching is the most frequently used approach for automated peptide assignment and protein inference of tandem mass spectra. The results, however, depend on the sequences in target databases and on search algorithms. Recently by using an alternative splicing database, we identified more proteins than with the annotated proteins in <it>Aspergillus flavus</it>. In this study, we aimed at finding a greater number of eligible splice variants based on newly available transcript sequences and the latest genome annotation. The improved database was then used to compare four search algorithms: Mascot, OMSSA, X! Tandem, and InsPecT.</p> <p>Results</p> <p>The updated alternative splicing database predicted 15833 putative protein variants, 61% more than the previous results. There was transcript evidence for 50% of the updated genes compared to the previous 35% coverage. Database searches were conducted using the same set of spectral data, search parameters, and protein database but with different algorithms. The false discovery rates of the peptide-spectrum matches were estimated < 2%. The numbers of the total identified proteins varied from 765 to 867 between algorithms. Whereas 42% (1651/3891) of peptide assignments were unanimous, the comparison showed that 51% (568/1114) of the RefSeq proteins and 15% (11/72) of the putative splice variants were inferred by all algorithms. 12 plausible isoforms were discovered by focusing on the consensus peptides which were detected by at least three different algorithms. The analysis found different conserved domains in two putative isoforms of UDP-galactose 4-epimerase.</p> <p>Conclusions</p> <p>We were able to detect dozens of new peptides using the improved alternative splicing database with the recently updated annotation of the <it>A. flavus </it>genome. Unlike the identifications of the peptides and the RefSeq proteins, large variations existed between the putative splice variants identified by different algorithms. 12 candidates of putative isoforms were reported based on the consensus peptide-spectrum matches. This suggests that applications of multiple search engines effectively reduced the possible false positive results and validated the protein identifications from tandem mass spectra using an alternative splicing database.</p
    corecore