604 research outputs found

    Application of parallel observation method for automobile testing

    Get PDF
    Обґрунтовано доцільність використання методу паралельних спостережень з метою підвищення точності визначення параметрів автомобіля при випробуваннях. Показано практичну реалізацію методу паралельних спостережень на прикладі вимірювання сил опору руху автомобіля.The expediency of application the method of parallel observation with the aim of increasing the determination point of automobile parameters in testing is grounded. It is shown practical realization of parallel observation method for example of measuring resistance powers at automobile motion

    Sedimentation Influence on Magnetorheological Brake Torque Moment

    No full text
    The aim of our research was to determine how sedimentation in magnetorheological fluid influences torque moment of a magnetorheological brake. Five different magnetorheological fluids (MRF-140CG, MRF-122EG, from Lord Corporation, USA, MRHCCS4-A and MRHCCS4-B are from Liquids Research Company, UK and MUDZH-3, made in A. V. Luikov Heat and Mass Transfer Institute, Belarus) were tested. The viscosity of these magnetorheological fluids in the magnetic field of 0–1 T was measured on Anton Paar Physica MCR-301 rheometer. We have selected the fluid with the best parameters to fill up our made magnetorheological brake. To determine sedimentation in magnetorheological fluid was used patent pending method by measuring fluids’ electrical resistivity. Electrical resistivity dependence on sedimentation mathematical model was created. Also four piezo-actuators were used to mix fluid inside the brake. Experimental setup to determine brakes’ torque moment was created.Исследуется влияние осаждения в магнитореологической жидкости на вязкое трение и крутящий момент магнитореологического тормоза. Протестировано пять различных магнитореологических жидкостей: MRF-140CG и MRF-122EG (корпорация Lord, США), MRHCCS4-A и MRHCCS4-B (компания Liquids, Великобритания) и MUDZH-3 (Ин-т тепло- и массообмена им. А. В. Лыкова НАН Беларуси). Вязкость магнитореологических жидкостей в магнитном поле интенсивностью 0 1 Т измеряли реометром типа Anton Paar Physica MCR-301. Для использования в магнитореологическом тормозе была выбрана жидкость с лучшими параметрами. Седиментацию в магнитореологической жидкости определяли запатентованным авторами методом, основанным на измерении электросопротивления жидкости. Разработана математическая модель вязкого трения и седиментации в зависимости от электросопротивления жидкости. Для смешивания жидкостей внутри магнитореологического тормоза использовали четыре пьезопривода. Создана экспериментальная установка для определения крутящего момента тормоза.Досліджується вплив осадження в магнітореологічній рідині на в язке тертя і крутний момент магнітореологічного гальма. Протестовано п ять різних магнітореологічних рідин: MRF-140CG i MRF-122EG (корпорація Lord, США), MRHCCS4-A і MRHCCS4-B (компанія Liquids, Великобританія) та MUDZH-3 (Ін-т тепло- та масообміну ім. О. В. Ликова НАН Білорусі). В язкість магнітореологічних рідин у магнітному полі інтенсивністю 0 1 Т вимірювали реометром типу Anton Paar Physica MCR-301. Для використання в магнітореологічному гальмі було вибрано рідину з кращими параметрами. Седиментацію в магнітореологічній рідині визначали запатентованим авторами методом, що базується на вимірюванні електроопору рідини. Розроблено математичну модель в'язкого тертя і седиментації в залежності від електроопору рідини. Для змішування рідин всередині магнітореологічного гальма використовували чотири п'єзоприводи. Розроблено експериментальну установку для визначення крутного моменту гальма

    A Cryogenic Silicon Interferometer for Gravitational-wave Detection

    Get PDF
    The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby universe, as well as observing the universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor

    Morphological and ultrasound features of liver fibrosis in children with autoimmune hepatitis

    Get PDF
    Aim. To study the ultrasound peculiarities of the liver parenchyma stiffness in children with autoimmune hepatitis by shear wave elastography comparing with the results of liver biopsy morphological investigation. Materials and methods. 40 children with autoimmune hepatitis were examined during the period of 2015–2018. All children were provided with a complex of laboratory tests according to the protocol, shear wave elastography of the liver and a puncture biopsy of the liver. The disease activity was ranged with the histological index of activity (IHA) according to Knodell by the results of a morphological study of liver biopsy and biochemical parameters (alanine aminotransferase, total bilirubin, gamma globulin, immunoglobulin G). The stage of the disease was estimated by the METAVIR histological index (HIS) and semi-quantitative elastography of the parenchyma shift wave. A comparison of the relationship between the histological activity of hepatitis and the parameters of the liver stiffness has been made. The changes in 23 children with hypertension were investigated in dynamics of liver stiffness (after 6 and 12 months of treatment). Result. A progressive fibrosis was diagnosed in 72.5 % (n = 29) (METAVIR F2) (χ2 = 16.2; P < 0.001 between the group of children with F1-2 and F3-4 METAVIR). The ROC analysis showed that, the optimal “cut-off point” for the diagnosis of F3 METAVIR fibrosis was the stiffness index of 9.4 kPa, and for F4 METAVIR – 13.0 kPa. Hepatitis activity influenced the stiffness of the liver parenchyma – with a decrease in the activity of the inflammatory process decreased and the rigidity of the liver parenchyma (P > 0.05). Conclusions. In 50 % of children with autoimmune hepatitis, the stage of fibrosis, which was determined by the method of elastography before treatment, corresponded to the data of the morphological study of liver biopsy. The activity of hepatitis affects the liver parenchyma stiffness, with the decrease of inflammatory process activity this index also decreases. The conducted research showed that in the process of treatment (anti-fibrotic and immunosuppressive therapy), after 6 and 12 months, the parameters of liver parenchyma severity decrease significantly (P < 0.05)

    The next detectors for gravitational wave astronomy

    Full text link
    This paper focuses on the next detectors for gravitational wave astronomy which will be required after the current ground based detectors have completed their initial observations, and probably achieved the first direct detection of gravitational waves. The next detectors will need to have greater sensitivity, while also enabling the world array of detectors to have improved angular resolution to allow localisation of signal sources. Sect. 1 of this paper begins by reviewing proposals for the next ground based detectors, and presents an analysis of the sensitivity of an 8 km armlength detector, which is proposed as a safe and cost-effective means to attain a 4-fold improvement in sensitivity. The scientific benefits of creating a pair of such detectors in China and Australia is emphasised. Sect. 2 of this paper discusses the high performance suspension systems for test masses that will be an essential component for future detectors, while sect. 3 discusses solutions to the problem of Newtonian noise which arise from fluctuations in gravity gradient forces acting on test masses. Such gravitational perturbations cannot be shielded, and set limits to low frequency sensitivity unless measured and suppressed. Sects. 4 and 5 address critical operational technologies that will be ongoing issues in future detectors. Sect. 4 addresses the design of thermal compensation systems needed in all high optical power interferometers operating at room temperature. Parametric instability control is addressed in sect. 5. Only recently proven to occur in Advanced LIGO, parametric instability phenomenon brings both risks and opportunities for future detectors. The path to future enhancements of detectors will come from quantum measurement technologies. Sect. 6 focuses on the use of optomechanical devices for obtaining enhanced sensitivity, while sect. 7 reviews a range of quantum measurement options

    The choice of solution volumes in the indirect intra-abdominal pressure measurement

    Get PDF
    The prospective clinical study focusing on the development of the indirect intra-abdominal pressure measurement procedure via the bladder was carried out in 30 patients in an intensive care unit. The change in abdominal pressure after infusion of isotonic furacilinum at 32-37 C° and consequent drainage of the bladder was investigated. It was determined that the increase of solution volumes that were infused (25 ml, 50 ml, 75 ml, and 100 ml) into the bladder caused the linear growth of intravesical pressure up to 9,5±5.3 10,8±5,3 11,6±5.1 12,4±5,2 cm H20 respectively. The increase in infused solution volumes brings about the rise of the pressure in the bladder that can lead to the overestimation of intra-abdominal pressure. The infusion of 25-50 ml of liquid into the bladder is considered to be sufficient for the indirect intra-abdominal pressure measurement.Проспективное клиническое исследование по разработке непрямого измерения внутрибрюшного давления через мочевой пузырь проведено у 30 больных палаты реанимации. Изучено изменение величины внутрибрюшного давления после введения и последующего сливания изотонического раствора фурацилина температурой 32-37 С0. Установлено, что при введении в мочевой пузырь 25, 50. 75 и 100 мл изотонического 0,02% раствора фурацилина наблюдался линейный рост давления в мочевом пузыре величина которого составила соответственно 9,5±5,3, 10,8±5,3, 11,6±5,1, 12,4±5,2 см водн.ст. Увеличение объема жидкости при инстилляции приводит к повышению давления в мочевом пузыре, что может привести к завышенной оценке величины давления в брюшной полости. Введение в мочевой пузырь жидкости в объеме 25-50 мл является достаточным для непрямого измерения внутрибрюшного давления

    First narrow-band search for continuous gravitational waves from known pulsars in advanced detector data

    Get PDF
    Spinning neutron stars asymmetric with respect to their rotation axis are potential sources of continuous gravitational waves for ground-based interferometric detectors. In the case of known pulsars a fully coherent search, based on matched filtering, which uses the position and rotational parameters obtained from electromagnetic observations, can be carried out. Matched filtering maximizes the signalto- noise (SNR) ratio, but a large sensitivity loss is expected in case of even a very small mismatch between the assumed and the true signal parameters. For this reason, narrow-band analysis methods have been developed, allowing a fully coherent search for gravitational waves from known pulsars over a fraction of a hertz and several spin-down values. In this paper we describe a narrow-band search of 11 pulsars using data from Advanced LIGO’s first observing run. Although we have found several initial outliers, further studies show no significant evidence for the presence of a gravitational wave signal. Finally, we have placed upper limits on the signal strain amplitude lower than the spin-down limit for 5 of the 11 targets over the bands searched; in the case of J1813-1749 the spin-down limit has been beaten for the first time. For an additional 3 targets, the median upper limit across the search bands is below the spin-down limit. This is the most sensitive narrow-band search for continuous gravitational waves carried out so far

    Исследование изменения перфузии в очагах демиелинизации при рассеянном склерозе методикой перфузионной МРТ

    Get PDF
    Introduction. Multiple sclerosis is a chronic immune-mediated disease of the central nervous system with disseminated foci of demyelination and progressive neurodegeneration; it is the most common demyelinating disease and the leading cause of disability of neurological patients of a young age, characterized by a wave-like course with alternating periods of remission and relapse. Currently, there is a discussion about the participation of vascular changes in the formation of neurological disorders and about the possibility of correction of therapeutic approaches in connection with the revealed microcirculatory disorders. Perfusion MRI allows you to evaluate hemodynamics at the capillary level in vivo. Purpose. To evaluate perfusion changes in foci of demyelination in multiple sclerosis using the method of dynamic susceptibility contrast (DSC). Materials and methods. The MR study was carried out on a super-high-angle MR-scanner «Ingenia» («Philips») 3 Tesla. The study included 30 healthy volunteers and 80 patients with demyelinating disease from 18 to 48 years old (average age was 34,6±8,02 years).Quantitative and qualitative assessment of perfusion indices in foci of demyelination was carried out. Results. In the active foci of demyelination, an increase in the speed and volume of cerebral blood flow is noted, the most pronounced changes in patients with clinically isolated syndrome. Inactive foci, marked hypoperfusion is noted. Discussion. Evaluation of cerebral perfusion allows a new look at the role of the vascular component in the formation of focal inflammatory changes in the brain in multiple sclerosis, which can determine a new direction of pathogenetic treatment. Conclusion. Perfusion data complements routine MRI and provides a comprehensive assessment of the neurovascular system.Введение. Рассеянный склероз — это хроническое иммуноопосредованное заболевание центральной нервной системы с диссеминированными очагами демиелинизации и прогрессирующей нейродегенерацией; является наиболее распространенным демиелинизирующим заболеванием и ведущей причиной инвалидизации неврологических пациентов молодого возраста, характеризующееся волнообразным течением с чередованием периодов ремиссии и рецидивов. В настоящее время ведется дискуссия об участии сосудистых изменений в формировании неврологических нарушений и о возможности коррекции терапевтических подходов в связи с выявленными микроциркуляторными нарушениями. Перфузионная МРТ позволяет оценивать гемодинамику на капиллярном уровне in vivo. Цель исследования: оценить перфузионные изменения в очагах демиелинизации при рассеянном склерозе с помощью методики динамической восприимчивости контраста (DSC). Материалы и методы. МР-исследование проводилось на сверхвысокопольном МР-томографе «Ingenia» («Philips») с напряженностью магнитного поля 3 Тл. В исследование было включено 30 здоровых добровольцев и 80 пациентов с установленным диагнозом «демиелинизирующее заболевание центральной нервной системы» в возрасте от 18 до 48 лет (средний возраст составил 34,6±8,02 лет). Проводилась количественная и качественная оценка показателей перфузии в очагах демиелинизации. Результаты. В активных очагах демиелинизации отмечается повышение скорости и объема церебрального кровотока, наиболее выражены изменения у пациентов с клинически изолированным синдромом. В неактивных очагах отмечается выраженная гипоперфузия. Заключение. Оценка церебральной перфузии позволяет по-новому взглянуть на роль сосудистого компонента в процессе формирования очаговых воспалительных изменения головного мозга при рассеянном склерозе, что может определить новое направление патогенетического лечения. Перфузионные данные дополняют рутинную МРТ и обеспечивают всестороннюю оценку нейроваскулярной системы
    corecore