1,298 research outputs found

    Characterising and Testing Deep UV LEDs for Use in Space Applications

    Full text link
    Deep ultraviolet (DUV) light sources are used to neutralise isolated test masses in highly sensitive space-based gravitational experiments. An example is the LISA Pathfinder charge management system, which uses low-pressure mercury lamps. A future gravitational-wave observatory such as eLISA will use UV light-emitting diodes (UV LEDs), which offer numerous advantages over traditional discharge lamps. Such devices have limited space heritage but are are now available from a number of commercial suppliers. Here we report on a test campaign that was carried out to quantify the general properties of three types of commercially available UV LEDs and demonstrate their suitability for use in space. Testing included general electrical and UV output measurements, spectral stability, pulsed performance, temperature dependence as well as thermal vacuum, radiation and vibration survivability

    Highly productive CO2 hydrogenation to methanol – a tandem catalytic approach via amide intermediates

    Get PDF
    A new system for CO2 reduction to methanol has been demonstrated using homogeneous ruthenium catalysts with a range of amine auxiliaries. Modification of this amine has a profound effect on the yield and selectivity of the reaction. A TON of 8900 and TOF of 4500 h−1 is achieved using a [RuCl2(Ph2PCH2CH2NHMe)2] catalyst with a diisopropylamine auxiliary

    The Labour Government, the Treasury and the £6 pay policy of July 1975

    Get PDF
    The 1974-79 Labour Government was elected in a climate of opinion that was fiercely opposed to government intervention in the wage determination process, and was committed to the principles of free collective bargaining in its manifestoes. However, by December 1974 the Treasury was advocating a formal incomes policy, and by July 1975 the government had introduced a £6 flat rate pay norm. With reference to archival sources, the paper demonstrates that TUC and Labour Party opposition to incomes policy was reconciled with the Treasury's advocacy by limiting the Bank of England‟s intervention in the foreign exchange market when sterling came under pressure. This both helped to achieve the Treasury's objective of improving the competitiveness of British industry, and acted as a catalyst for the introduction of incomes policy because the slide could be attributed to a lack of market confidence in British counter-inflation policy

    The LISA PathFinder DMU and Radiation Monitor

    Get PDF
    The LISA PathFinder DMU (Data Management Unit) flight model was formally accepted by ESA and ASD on 11 February 2010, after all hardware and software tests had been successfully completed. The diagnostics items are scheduled to be delivered by the end of 2010. In this paper we review the requirements and performance of this instrumentation, specially focusing on the Radiation Monitor and the DMU, as well as the status of their programmed use during mission operations, on which work is ongoing at the time of writing.Comment: 11 pages, 7 figures, prepared for the Proceedings of the 8th International LISA Symposium, Classical and Quantum Gravit

    Charge Management for Gravitational Wave Observatories using UV LEDs

    Full text link
    Accumulation of electrical charge on the end mirrors of gravitational wave observatories, such as the space-based LISA mission and ground-based LIGO detectors, can become a source of noise limiting the sensitivity of such detectors through electronic couplings to nearby surfaces. Torsion balances provide an ideal means for testing gravitational wave technologies due to their high sensitivity to small forces. Our torsion pendulum apparatus consists of a movable Au-coated Cu plate brought near a Au-coated Si plate pendulum suspended from a non-conducting quartz fiber. A UV LED located near the pendulum photoejects electrons from the surface, and a UV LED driven electron gun directs photoelectrons towards the pendulum surface. We have demonstrated both charging and discharging of the pendulum with equivalent charging rates of \sim105e/s10^5 e/\mathrm{s}, as well as spectral measurements of the pendulum charge resulting in a white noise level equivalent to 3×105e/Hz3\times10^5 e/\sqrt{Hz}.Comment: 5 pages, submitted to PR

    Gas damping force noise on a macroscopic test body in an infinite gas reservoir

    Full text link
    We present a simple analysis of the force noise associated with the mechanical damping of the motion of a test body surrounded by a large volume of rarefied gas. The calculation is performed considering the momentum imparted by inelastic collisions against the sides of a cubic test mass, and for other geometries for which the force noise could be an experimental limitation. In addition to arriving at an accurated estimate, by two alternative methods, we discuss the limits of the applicability of this analysis to realistic experimental configurations in which a test body is surrounded by residual gas inside an enclosure that is only slightly larger than the test body itself.Comment: 8 pages. updated with correct translational damping coefficient for cylinder on axis. added cylinder orthogonal to symmetry axis, force and torque. slightly edited throughou

    LISA and LISA PathFinder, the endeavour to detect low frequency GWs

    Full text link
    This is a review about LISA and its technology demonstrator, LISA PathFinder. We first describe the conceptual problems which need to be overcome in order to set up a working interferometric detector of low frequency Gravitational Waves (GW), then summarise the solutions to them as currently conceived by the LISA mission team. This will show that some of these solutions require new technological abilities which are still under development, and which need proper test before being fully implemented. LISA PathFinder (LPF) is the the testbed for such technologies. The final part of the paper will address the ideas and concepts behind the PathFinder as well as their impact on LISA.Comment: 25 pages, 21 figures, presented at the Spanish Relativity Meeting, Mallorca September 2006. Will be published in Journal of Physics: Conference Series, IOP. To be published in Journal of Physics: Conference Series, IO

    Using item response theory to explore the psychometric properties of extended matching questions examination in undergraduate medical education

    Get PDF
    BACKGROUND: As assessment has been shown to direct learning, it is critical that the examinations developed to test clinical competence in medical undergraduates are valid and reliable. The use of extended matching questions (EMQ) has been advocated to overcome some of the criticisms of using multiple-choice questions to test factual and applied knowledge. METHODS: We analysed the results from the Extended Matching Questions Examination taken by 4th year undergraduate medical students in the academic year 2001 to 2002. Rasch analysis was used to examine whether the set of questions used in the examination mapped on to a unidimensional scale, the degree of difficulty of questions within and between the various medical and surgical specialties and the pattern of responses within individual questions to assess the impact of the distractor options. RESULTS: Analysis of a subset of items and of the full examination demonstrated internal construct validity and the absence of bias on the majority of questions. Three main patterns of response selection were identified. CONCLUSION: Modern psychometric methods based upon the work of Rasch provide a useful approach to the calibration and analysis of EMQ undergraduate medical assessments. The approach allows for a formal test of the unidimensionality of the questions and thus the validity of the summed score. Given the metric calibration which follows fit to the model, it also allows for the establishment of items banks to facilitate continuity and equity in exam standards
    corecore