14,306 research outputs found
Acoustical evaluation of the NASA Lewis 9 by 15 foot low speed wind tunnel
The test section of the NASA Lewis 9- by 15-Foot Low Speed Wind Tunnel was acoustically treated to allow the measurement of acoustic sources located within the tunnel test section under simulated free field conditions. The treatment was designed for high sound absorption at frequencies above 250 Hz and to withstand tunnel airflow velocities up to 0.2 Mach. Evaluation tests with no tunnel airflow were conducted in the test section to assess the performance of the installed treatment. This performance would not be significantly affected by low speed airflow. Time delay spectrometry tests showed that interference ripples in the incident signal resulting from reflections occurring within the test section average from 1.7 dB to 3.2 dB wide over a 500 to 5150 Hz frequency range. Late reflections, from upstream and downstream of the test section, were found to be insignificant at the microphone measuring points. For acoustic sources with low directivity characteristics, decay with distance measurements in the test section showed that incident free field behavior can be measured on average with an accuracy of +/- 1.5 dB or better at source frequencies from 400 Hz to 10 kHz. The free field variations are typically much smaller with an omnidirectional source
A finite element model for wave propagation in an inhomogeneous material including experimental validation
A finite element model was developed to solve for the acoustic pressure field in a nonhomogeneous region. The derivations from the governing equations assumed that the material properties could vary with position resulting in a nonhomogeneous variable property two-dimensional wave equation. This eliminated the necessity of finding the boundary conditions between the different materials. For a two media region consisting of part air (in the duct) and part bulk absorber (in the wall), a model was used to describe the bulk absorber properties in two directions. An experiment to verify the numerical theory was conducted in a rectangular duct with no flow and absorbing material mounted on one wall. Changes in the sound field, consisting of planar waves was measured on the wall opposite the absorbing material. As a function of distance along the duct, fairly good agreement was found in the standing wave pattern upstream of the absorber and in the decay of pressure level opposite the absorber
Comparison between design and installed acoustic characteristics of NASA Lewis 9- by 15-foot low-speed wind tunnel acoustic treatment
The test section of the NASA Lewis 9- by 15-Foot Low-Speed Wind Tunnel was acoustically treated to allow the measurement of sound under simulated free-field conditions. The treatment was designed for high sound absorption at frequencies above 250 Hz and for withstanding the environmental conditions in the test section. In order to achieve the design requirements, a fibrous, bulk-absorber material was packed into removable panel sections. Each section was divided into two equal-depth layers packed with material to different bulk densities. The lower density was next to the facing of the treatment. The facing consisted of a perforated plate and screening material layered together. Sample tests for normal-incidence acoustic absorption were also conducted in an impedance tube to provide data to aid in the treatment design. Tests with no airflow, involving the measurement of the absorptive properties of the treatment installed in the 9- by 15-foot wind tunnel test section, combined the use of time-delay spectrometry with a previously established free-field measurement method. This new application of time-delay spectrometry enabled these free-field measurements to be made in nonanechoic conditions. The results showed that the installed acoustic treatment had absorption coefficients greater than 0.95 over the frequency range 250 Hz to 4 kHz. The measurements in the wind tunnel were in good agreement with both the analytical prediction and the impedance tube test data
Measured acoustic properties of variable and low density bulk absorbers
Experimental data were taken to determine the acoustic absorbing properties of uniform low density and layered variable density samples using a bulk absober with a perforated plate facing to hold the material in place. In the layered variable density case, the bulk absorber was packed such that the lowest density layer began at the surface of the sample and progressed to higher density layers deeper inside. The samples were placed in a rectangular duct and measurements were taken using the two microphone method. The data were used to calculate specific acoustic impedances and normal incidence absorption coefficients. Results showed that for uniform density samples the absorption coefficient at low frequencies decreased with increasing density and resonances occurred in the absorption coefficient curve at lower densities. These results were confirmed by a model for uniform density bulk absorbers. Results from layered variable density samples showed that low frequency absorption was the highest when the lowest density possible was packed in the first layer near the exposed surface. The layers of increasing density within the sample had the effect of damping the resonances
WHEAT PRODUCTION IN TUNISIA: TRENDS AND VARIABILITIES
Crop Production/Industries,
A non-existence result for a generalization of the equations of the conformal method in general relativity
The constraint equations of general relativity can in many cases be solved by
the conformal method. We show that a slight modification of the equations of
the conformal method admits no solution for a broad range of parameters. This
suggests that the question of existence or non-existence of solutions to the
original equations is more subtle than could perhaps be expected.Comment: minor changes from previous versio
Some Observations on Transitory Stall in Conical Diffusers
Results from an experimental investigation on the flow through conical diffusers are presented. The mean and fluctuating velocity fields are compared for three diffusers with total diffusion angles of 16, 20 and 24 degrees, in the throat Mach number (M sub t) range of 0.05 to 0.95. Each of the diffusers were 14 cm long and had a 5.08 cm inlet diameter, and the flow exited into the ambient. The boundary layer at the throat was thin with the throat diameter (D sub t) to momentum thickness (O) ratio being as high as 800 at M(sub t) = 0.4. While the 16 deg diffuser flow exited with a top-hat mean velocity profile, increasing losses due to increasing separation resulted in fuller profiles for the 20 and 24 degree cases. A detailed flow field study was conducted for the 16 deg. diffuser. The u'-spectrum, measured at the exit plane, exhibited a peak apparently due to the ensuing jet column instability throughout the M(sub t) range covered. In addition, a much lower frequency spectral peak also occurred in the M(sub t) range of 0.3 to 0.7. Both of the spectral peaks were due to axisymmetric flow fluctuations. A self-sustaining flow oscillation occurred in the M(sub t) range of 0.6 to 0.85, emitting a loud tone, when the jet column instability frequency matched the resonance frequency of the diffuser. Limited data showed that artificial acoustic excitation was effective in reducing the flow fluctuations, with a resultant increase in the pressure recovery, at low M(sub t)
Does the Community Reinvestment Act influence lending? an analysis of changes in bank low-income mortgage activity
Anecdotal evidence that the Community Reinvestment Act (CRA) influences the lending behavior of financial institutions has not been uniformly supported by empirical research. We revisit this issue by evaluating changes in low-income mortgage lending at commercial banks over the 1992-96 period. Our empirical results fail to support a hypothesis that banks respond to public and regulatory pressure exerted as a result of a downgrade in CRA rating by increasing low-income mortgage lending. The findings are consistent with the contention that during this period regulators stressed adjustments in the lending process of banks (e.g., documentation of lending program and efforts directed at targeted markets) more than lending performance. The findings underscore the importance of regulatory efforts made later in the decade to more closely link enforcement of the CRA to lending outcomes.Community Reinvestment Act of 1977 ; Mortgages ; Bank loans ; Financial institutions
HOW GOOD ARE INPUT DEMAND MODELS USED IN PREVIOUS STUDIES NOW?
Demand and Price Analysis,
THE DEMAND FOR FARM MACHINERY
Demand and Price Analysis, Farm Management,
- …