8 research outputs found
Determining anaerobic threshold through heart rate variability in patients with COPD during cycloergometer exercise
INTRODUCTION: Chronic Obstructive Pulmonary Disease (COPD) is characterized by structural alterations of lung parenchyma resulting in systemic manifestations. These patients may have marked change in cardiac autonomic control. In this context, studies investigating heart rate variability (HRV) in patients with COPD during physical exercise cycloergometers have been little explored. OBJECTIVE: To determine the anaerobic threshold through HRV in order to establish parameters of evaluation and prescription of exercise intensity in these patients on a cycloergometer. MATERIALS AND METHODS: Eight male patients diagnosed with COPD, mean age 69.5 ± 7.6 years were studied. Heart rate was analyzed at rest and at different intensities of exercise. The test was performed on a cycloergometer and consisted of a warm-up period of four minutes at a minimum power. Steps were performed with initial power of 4W, with increments of 5 in 5W, until the patient reached the anaerobic threshold. RESULTS: Patients that presented higher values of FEV1 showed greater powers during the cycloergometer. Additionally, there was significant reduction in HRV during exercise compared to rest sitting p < 0.05. CONCLUSION: Patients had a severe physical deconditioning reaffirmed the impossibility determined by the anaerobic threshold of 50% of the sample.INTRODUÇÃO: A Doença Pulmonar Obstrutiva Crônica (DPOC) é caracterizada por alterações estruturais do parênquima pulmonar, acarretando manifestações sistêmicas. Além disso, esses pacientes podem apresentar marcada alteração do controle autonômico cardíaco. Nesse contexto, estudos investigando a variabilidade da frequência cardíaca (VFC) em pacientes com DPOC durante a realização de exercício físico em cicloergometro têm sido pouco explorados. OBJETIVO: Determinar o limiar anaeróbio por meio da VFC com o propósito de estabelecer parâmetros de avaliação e prescrição da intensidade de exercício desses pacientes em cicloergômetro. MATERIAIS E MÉTODOS: Foram avaliados oito pacientes do sexo masculino com diagnóstico de DPOC com idade média de 69,5 ± 7,6 anos. A frequência cardíaca foi analisada no repouso e em diferentes intensidades do exercício. O teste foi realizado em um cicloergômetro e consistiu em um período de aquecimento de quatro minutos em uma potência mínima. Foram, também, realizados degraus com potência inicial de 4W, com acréscimos de 5 em 5W, até que o paciente atingisse o limiar anaeróbio. RESULTADOS: Os pacientes que apresentaram maiores valores de VEF1 apresentaram maiores potências no cicloergômetro. Houve redução significativa da VFC durante o exercício físico se comparado ao repouso sentado p < 0,05. CONCLUSÃO: Os pacientes estudados apresentaram um severo descondicionamento físico reafirmado pela impossibilidade determinada pelo LA de 50% da amostra.Universidade Federal de São Carlos Departamento de Fisioterapia Núcleo de Pesquisa em Exercício FísicoUniversidade Federal de São Carlos Fisioterapia CardiovascularUniversidade Federal de São Paulo (UNIFESP) MedicinaUniversidade Federal de São Carlos GeriatriaUniversidade de Federal de São Carlos FisioterapiaUNIFESP, MedicinaSciEL
EFEITOS DO TREINAMENTO DE FORÇA SOBRE A FUNÇÃO PANCREÁTICA E A SENSIBILIDADE TECIDUAL À INSULINA EM RATOS
Estudos tm demonstrado que o exerccio aerbio promove elevao na sensibilidade tecidual insulina (SI) e na tolerncia glicose (TG), porm a anlise de tais variveis aps treinamento de fora (TF) tem sido pouco explorada. Assim, o objetivo deste estudo foi avaliar os efeitos do TF sobre a TG e SI em ratos. Foram estudados 20 ratos Wistar, pareados por peso e aleatoriamente distribudos em 2 grupos: G1 Sham e G2 TF. Todos os animais foram submetidos a 3 dias de adaptao e, subsequentemente, treinados com cargas progressivas por 3 vezes por semana, durante 8 semanas numa escada de madeira. Para avaliar SI e TG foram realizadas coletas de sangue e avaliada a cintica da glicemia pelo teste de tolerncia insulina (% de decaimento da curva; B) e o teste de tolerncia glicose (rea sob a curva; AC), antes da adaptao e aps o 24 dia de treinamento. A anlise estatstica foi realizada pelo teste t de Student pareado e no-pareado, sendo o p 0,05. Apenas G2 mostrou significativo aumento no B aps treinamento, sendo que o delta do B entre os grupos mostrou diferenas significativas (p 0,05), com maiores valores no G2. Em contraste, AC no apresentou alterao significativa entre os grupos nem entre os deltas (p 0,05). O TF promoveu benefcios adaptativos na sensibilidade tecidual insulina, sugerindo que o TF pode ser um recurso interessante durante programas de fisioterapia cardiovascular em doenas crnicas
Ajustes e adaptações do exercício físico resistido de baixa intensidade e longas séries nas variáveis autonômicas, ventilatórias, musculares e hemodinâmicas em idosos com doença arterial coronariana
The thesis consisted of three studies described below. The study I, entitled
"Hemodynamic and metabolic response during aerobic and resistance dynamic
exercise in different intensities: A cross-sectional study on implications of intensity on
safety and symptoms in patients with coronary disease". Where the objective of this
study was to evaluate the clinical and physiological responses during resistance
exercise in loads of 30 and 60% of 1-RM on the leg press 45° and compare the
responses with maximum aerobic exercise. The evaluation included aerobic test on
cycle ergometer and resistance test in leg press 45°. Ventilation, hemodynamic and
clinical measurements were performed. The results showed that 60% of resistance
exercise and the dynamic test increased variables response studied in compared the
load of 30% in resistance exercise. We conclude that high repetition of resistance
exercise results in physiological changes at an intensity comparable to maximal
aerobic exercise. Further, the study II, entitled "Resistance training improves heart rate
variability and muscular performance: A randomized controlled trial in patients with
coronary artery disease study" The objective was to investigate the effects of a high
repetition program/low load resistance training (RT) (HR/LL-RT) in heart rate variability
(HRV) in muscular strength and endurance in patients with CAD. Test were carried out
in 1-RM test in leg press 45°, HRV was captured in the supine position before and after
eight weeks of RT. The HR/LL-RT program consisted of an exercise using leg press
45°; (three sets, twenty repetitions, twice a week for eight weeks). The results showed
that after eight weeks RT there was a significant increase in the values of the RMSSD,
ApEn SD1 indices and only the TG (p<0.05). There was a significant decrease in Mean
HR after RT for TG (p<0.05). Additionally, there was significant improvement in
muscular strength and endurance only for the TG (p<0.05). We conclude that eight
weeks of HR/LL-RT is a sufficient stimulus to change heart function, muscle strength
and endurance in patients with CAD. Finally, the study III, entitled: ''What the impact of
resistance training on hemodynamic, autonomic and metabolic variables in coronary
artery disease patients? The randomized controlled trial of eight weeks''. Where the
objective was to evaluate the hemodynamic, metabolic, and the HRV effects during
maximum intensity tolerated in constant loads protocols during dynamic and resistance
exercise before and after eight weeks of resistance training program of low intensity
and high reps (RTLHr) in patients with CAD. The results showed increase in maximum
and submaximal load (p<0.01) and attenuation of the hemodynamic performance in the
higher load (p<0.01) and reduced lactate concentration compared for TG. During the
cycle ergometer exercise, there was attenuation of hemodynamic performance and
increased minute ventilation (p<0.01). Finally, the TRBAr produced greater
parasympathetic contribution (RMSSD and SD1), after RT. We conclude that eight
weeks of RTLHr may attenuate the hemodynamic stress, metabolic and autonomic
during resistance exercise with cardiovascular and autonomic beneficial effects also in
the dynamic exercise.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)A tese constou de três estudos descritos a seguir. O estudo I, intitulado: “Respostas
hemodinâmicas e metabólicas durante o exercício dinâmico aeróbio e resistido em
diferentes intensidades: Um estudo transversal com implicações da intensidade na
segurança e sintomas nos pacientes com doença coronariana”, cujo o objetivo foi
avaliar as respostas clínicas e fisiológicas durante o exercício resistido nas cargas de
30 e 60% de 1-RM no leg press 45° e comparar as respostas durante o exercício
aeróbio máximo. A avaliação incluiu teste aeróbio no cicloergômetro e teste resistido
no leg press 45°. Foram realizadas medidas ventilatórias, hemodinâmicas e clínicas.
Os resultados apresentaram que na carga de 60% do exercício resistido e no teste
dinâmico aumentaram a resposta nas variáveis estudadas quando comparados a
carga de 30% no exercício resistido. Concluímos que altas repetições de exercício
resistido resulta em modificações fisiológicas a uma intensidade comparável ao
exercício aeróbio máximo. Na sequência, o estudo II, intitulado: “Treinamento resistido
melhora a variabilidade da frequência cardíaca e o desempenho muscular: um estudo
randomizado e controlado em pacientes com doença arterial coronariana.” O objetivo
foi investigar os efeitos de um programa de alta repetição/baixa carga de treinamento
resistido (TR) (AR/BC-TR) na variabilidade da frequência cardíaca (VFC), na força e
resistência muscular em pacientes com doença arterial coronariana (DAC). Foram
realizados teste de 1-RM, teste descontínuo no leg press 45°; a VFC foi captada na
posição supina antes e após oito semanas de TR. O programa AR/BC-TR consistiu de
um exercício utilizando leg press 45°; (três séries de vinte repetições, duas vezes por
semana durante oito semanas). Os resultados mostraram que, após oito semanas de
TR, houve aumento significativo dos valores dos índices RMSSD, SD1 e ApEn apenas
para o GT (p<0,05). Houve uma diminuição significativa na média de FC após TR para
GT (p<0,05). Adicionalmente, houve melhora significativa na força e resistência
muscular apenas para o GT (p<0,05). Concluímos que oito semanas de AR/BC-TR
foram um estímulo suficiente para alterar a função cardíaca, bem como a força e
resistência muscular em pacientes com DAC. Finalmente, o estudo III, intitulado: ''Qual
o impacto do treinamento resistido nas variáveis, hemodinâmicas, autonômicas e
metabólicas em pacientes com doença arterial coronariana? Um estudo randomizado
e controlado de 8 semanas'', cujo objetivo foi verificar os efeitos hemodinâmicos,
metabólicos e da VFC durante a intensidade máxima tolerada em protocolos de cargas
constantes de resistência e dinâmico antes e após oito semanas de programa de
treinamento resistido de baixa intensidade e altas repetições (TRBAr) em pacientes
com DAC. Os resultados mostraram aumento da carga máxima e submáxima
(p<0,01) e atenuação da performance hemodinâmica na maior carga atingida (p<0,01)
e redução da concentração de lactato para o GT. Durante o exercício em
cicloergômetro, houve atenuação da performance hemodinâmica e aumento da
ventilação minuto (p<0,01). Finalmente, o TRBAr produziu maior contribuição
parassimpática (RMSSD e SD1), após o TR. Concluímos que oito semanas de TRBAr
pode atenuar o estresse hemodinâmico, metabólico e autonômico durante o exercício
resistido, com efeitos benéficos cardiovasculares e autonômicos também no exercício
dinâmico
Determinação do limiar anaeróbio pela variabilidade da frequência cardíaca de pacientes com DPOC durante exercício em cicloergômetro
Introdução: A Doença Pulmonar Obstrutiva Crônica (DPOC) é caracterizada por alterações estruturais do parênquima pulmonar, acarretando manifestações sistêmicas. Além disso, esses pacientes podem apresentar marcada alteração do controle autonômico cardíaco. Nesse contexto, estudos investigando a variabilidade da frequência cardíaca (VFC) em pacientes com DPOC durante a realização de exercício físico emcicloergometro têm sido pouco explorados. Objetivo: Determinar o limiar anaeróbio por meio da VFC com o propósito de estabelecer parâmetros de avaliação e prescrição da intensidade de exercício desses pacientes em cicloergômetro. Materiais e métodos: Foram avaliados oito pacientes do sexo masculino com diagnóstico de DPOC com idade média de 69,5 ± 7,6 anos. A frequência cardíaca foi analisada no repouso e em diferentes intensidades do exercício. O teste foi realizado em um cicloergômetro e consistiu em um período de aquecimento de quatro minutos em uma potência mínima. Foram, também, realizados degraus com potência inicial de 4W, com acréscimos de 5 em 5W, até que o paciente atingisse o limiar anaeróbio. Resultados: Os pacientes que apresentaram maiores valores de VEF1 apresentaram maiores potências no cicloergômetro. Houve redução significativa da VFC durante o exercício físico se comparado ao repouso sentado p elt; 0,05. Conclusão: Os pacientes estudados apresentaram um severo descondicionamento físico reafirmado pela impossibilidade determinada pelo LA de 50% da amostra
Determinação do limiar anaeróbio pela variabilidade da frequência cardíaca de pacientes com DPOC durante exercício em cicloergômetro
INTRODUÇÃO: A Doença Pulmonar Obstrutiva Crônica (DPOC) é caracterizada por alterações estruturais do parênquima pulmonar, acarretando manifestações sistêmicas. Além disso, esses pacientes podem apresentar marcada alteração do controle autonômico cardíaco. Nesse contexto, estudos investigando a variabilidade da frequência cardíaca (VFC) em pacientes com DPOC durante a realização de exercício físico em cicloergometro têm sido pouco explorados. OBJETIVO: Determinar o limiar anaeróbio por meio da VFC com o propósito de estabelecer parâmetros de avaliação e prescrição da intensidade de exercício desses pacientes em cicloergômetro. MATERIAIS E MÉTODOS: Foram avaliados oito pacientes do sexo masculino com diagnóstico de DPOC com idade média de 69,5 ± 7,6 anos. A frequência cardíaca foi analisada no repouso e em diferentes intensidades do exercício. O teste foi realizado em um cicloergômetro e consistiu em um período de aquecimento de quatro minutos em uma potência mínima. Foram, também, realizados degraus com potência inicial de 4W, com acréscimos de 5 em 5W, até que o paciente atingisse o limiar anaeróbio. RESULTADOS: Os pacientes que apresentaram maiores valores de VEF1 apresentaram maiores potências no cicloergômetro. Houve redução significativa da VFC durante o exercício físico se comparado ao repouso sentado p < 0,05. CONCLUSÃO: Os pacientes estudados apresentaram um severo descondicionamento físico reafirmado pela impossibilidade determinada pelo LA de 50% da amostra
Glycemic behavior in patients with type 2 diabetes during a short period of a combined training program
Abstract Aim: The present study investigated the behavior of glycemia in subjects with type 2 diabetes (T2DM) during 36 sessions of a combined training program. Methods: This is a single arm clinical study with 20 patients with T2DM submitted to combined exercise training (strength and aerobic exercise). The sessions occurred on alternate days, 3x/week, lasting ~ 80 minutes, totaling ~ 240 minutes/week, for 12 weeks, over a total of 36 sessions. Capillary glycemia was measured before and 10 to 15 minutes after the end of each combined exercise session. Results: There was a significant reduction (p0.05). When investigating the cumulative effect of the 36 sessions of combined training program on capillary glycemia, no significant differences were observed (p>0.05). Conclusion: Glycemia exhibits a behavior of reduction immediately after concurrent strength and aerobic training programs in patients with T2DM. However, the immediate reduction of glycemia is not maintained until 48 hours, nor is there a cumulative effect of the 36 training sessions on baseline glycemia