1,377 research outputs found

    Design, fabrication, and experimental validation of novel flexible silicon-based dry sensors for electroencephalography signal measurements

    Full text link
    © 2014 IEEE. Many commercially available electroencephalography (EEG) sensors, including conventional wet and dry sensors, can cause skin irritation and user discomfort owing to the foreign material. The EEG products, especially sensors, highly prioritize the comfort level during devices wear. To overcome these drawbacks for EEG sensors, this paper designs Societe Generale de Surveillance S A c(SGS)-certified, silicon-based dry-contact EEG sensors (SBDSs) for EEG signal measurements. According to the SGS testing report, SBDSs extract does not irritate skin or induce noncytotoxic effects on L929 cells according to ISO10993-5. The SBDS is also lightweight, flexible, and nonirritating to the skin, as well as capable of easily fitting to scalps without any skin preparation or use of a conductive gel. For forehead and hairy sites, EEG signals can be measured reliably with the designed SBDSs. In particular, for EEG signal measurements at hairy sites, the acicular and flexible design of SBDS can push the hair aside to achieve satisfactory scalp contact, as well as maintain low skin-electrode interface impedance. Results of this paper demonstrate that the proposed sensors perform well in the EEG measurements and are feasible for practical applications

    The Clinical Application of Anti-CCP in Rheumatoid Arthritis and Other Rheumatic Diseases

    Get PDF
    Rheumatoid arthritis (RA) is a common rheumatic disease in Caucasians and in other ethnic groups. Diagnosis is mainly based on clinical features. Before 1998, the only serological laboratory test that could contribute to the diagnosis was that for rheumatoid factor (RF). The disease activity markers for the evaluation of clinical symptoms or treatment outcome were the erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP). As a matter of fact, the diagnosis of early RA is quite impossible, as the clinical criteria are insufficient at the beginning stage of the disease. In 1998, Schelleken reported that a high percentage of RA patients had a specific antibody that could interact with a synthetic peptide which contained the amino acid citrulline. The high specificity (98%) for RA of this new serological marker, anti-cyclic citrullinated antibody (anti-CCP antibody), can be detected early in RA, before the typical clinical features appear. The presence or absence of this antibody can easily distinguish other rheumatic diseases from RA. Additionally, the titer of anti-CCP can be used to predict the prognosis and treatment outcome after DMARDs or biological therapy. Therefore, with improvement of sensitivity, the anti-CCP antibody will be widely used as a routine laboratory test in the clinical practice for RA

    Melanotic oncocytic metaplasia of the nasopharynx as a benign mimicker of malignant melanoma: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Melanotic variant of oncocytic metaplasia of the nasopharynx is an extremely rare condition.</p> <p>Case report</p> <p>A 73-year-old Japanese man presented with nasal congestion and chill. Nasoscopic examination revealed multiple black nodules around the bilateral torus tubarius. The nodules were biopsied to determine the histology. The clinical differential diagnosis was malignant melanoma or hemangioma. Microscopically, there were oncocytic plump cells with abundant brown pigmented granules showing glandular pattern. No significant atypia was found. The pigment was positive for Fontana-Masson staining, and negative for Berlin blue staining, showing that it was melanin pigment. Immunohistochemically, S100-positive HMB45-negative dendritic cells were also found.</p> <p>Conclusion</p> <p>Such a pigmented variant of benign oncocytic lesion is very rare, and only 15 cases have been reported in the English literature. As a benign mimicker of malignant melanoma, melanocytic oncocytic metaplasia should be always taken into consideration in the clinical setting.</p

    Exploring the Brain Responses to Driving Fatigue through Simultaneous EEG and fNIRS Measurements

    Full text link
    © 2020 World Scientific Publishing Company. Fatigue is one problem with driving as it can lead to difficulties with sustaining attention, behavioral lapses, and a tendency to ignore vital information or operations. In this research, we explore multimodal physiological phenomena in response to driving fatigue through simultaneous functional near-infrared spectroscopy (fNIRS) and electroencephalography (EEG) recordings with the aim of investigating the relationships between hemodynamic and electrical features and driving performance. Sixteen subjects participated in an event-related lane-deviation driving task while measuring their brain dynamics through fNIRS and EEGs. Three performance groups, classified as Optimal, Suboptimal, and Poor, were defined for comparison. From our analysis, we find that tonic variations occur before a deviation, and phasic variations occur afterward. The tonic results show an increased concentration of oxygenated hemoglobin (HbO2) and power changes in the EEG theta, alpha, and beta bands. Both dynamics are significantly correlated with deteriorated driving performance. The phasic EEG results demonstrate event-related desynchronization associated with the onset of steering vehicle in all power bands. The concentration of phasic HbO2 decreased as performance worsened. Further, the negative correlations between tonic EEG delta and alpha power and HbO2 oscillations suggest that activations in HbO2 are related to mental fatigue. In summary, combined hemodynamic and electrodynamic activities can provide complete knowledge of the brain's responses as evidence of state changes during fatigue driving

    Cognition in action: Imaging brain/body dynamics in mobile humans

    Full text link
    We have recently developed a mobile brain imaging method (MoBI), that allows for simultaneous recording of brain and body dynamics of humans actively behaving in and interacting with their environment. A mobile imaging approach was needed to study cognitive processes that are inherently based on the use of human physical structure to obtain behavioral goals. This review gives examples of the tight coupling between human physical structure with cognitive processing and the role of supraspinal activity during control of human stance and locomotion. Existing brain imaging methods for actively behaving participants are described and new sensor technology allowing for mobile recordings of different behavioral states in humans is introduced. Finally, we review recent work demonstrating the feasibility of a MoBI system that was developed at the Swartz Center for Computational Neuroscience at the University of California, San Diego, demonstrating the range of behavior that can be investigated with this method. Copyright © 2011 by Walter de Gruyter, Berlin, Boston

    A novel 16-channel wireless system for electroencephalography measurements with dry spring-loaded sensors

    Full text link
    Understanding brain function using electroencephalography (EEG) is an important issue for cerebral nervous system diseases, especially for epilepsy and Alzheimer's disease. Many EEG measurement systems are used reliably to study these diseases, but their bulky size and the use of wet sensors make them uncomfortable and inconvenient for users. To overcome the limitations of conventional EEG measurement systems, a wireless and wearable multichannel EEG measurement system is proposed in this paper. This system includes a wireless data acquisition device, dry spring-loaded sensors, and a sizeadjustable soft cap. We compared the performance of the proposed system using dry versus conventional wet sensors. A significant positive correlation between readings from wet and dry sensors was achieved, thus demonstrating the performance of the system. Moreover, four different features of EEG signals (i.e., normal, eye-blinking, closed-eyes, and teeth-clenching signals) were measured by 16 dry sensors to ensure that they could be detected in real-life cognitive neuroscience applications. Thus, we have shown that it is possible to reliably measure EEG signals using the proposed system. This paper presents novel insights into the field of cognitive neuroscience, showing the possibility of studying brain function under real-life conditions. © 2014 IEEE

    Investigation of the cerebral hemodynamic response function in single blood vessels by functional photoacoustic microscopy

    Full text link
    The specificity of the hemodynamic response function (HRF) is determined spatially by the vascular architecture and temporally by the evolution of hemodynamic changes. Here, we used functional photoacoustic microscopy (fPAM) to investigate single cerebral blood vessels of rats after left forepaw stimulation. In this system, we analyzed the spatiotemporal evolution of the HRFs of the total hemoglobin concentration (HbT), cerebral blood volume (CBV), and hemoglobin oxygen saturation (SO2). Changes in specific cerebral vessels corresponding to various electrical stimulation intensities and durations were bilaterally imaged with 36 × 65-μm2 spatial resolution. Stimulation intensities of 1, 2, 6, and 10 mA were applied for periods of 5 or 15 s. Our results show that the relative functional changes in HbT, CBV, and SO2 are highly dependent not only on the intensity of the stimulation, but also on its duration. Additionally, the duration of the stimulation has a strong influence on the spatiotemporal characteristics of the HRF as shorter stimuli elicit responses only in the local vasculature (smaller arterioles), whereas longer stimuli lead to greater vascular supply and drainage. This study suggests that the current fPAM system is reliable for studying relative cerebral hemodynamic changes, as well as for offering new insights into the dynamics of functional cerebral hemodynamic changes in small animals. © 2012 Society of Photo-Optical Instrumentation Engineers (SPIE)

    Gout penyakit lama dihidapi manusia

    Get PDF
    This paper proposes a differential evolution with local information for TSK-type neuro-fuzzy system optimization. The differential evolution with local information consider neighborhood between each individual to keep the diversity of population. An adaptive parameter tuning based on 1/5th rule is used to trade off between local search and global search. For structure learning algorithm, the on-line clustering algorithm is used for rule generation. The structure learning algorithm generates a new rule which compares the firing strength. Initially, there is no rule in neuro-fuzzy system model. The rules are automatically generated by fuzzy measure. For parameter learning, the parameters are optimized by differential evolution algorithm. Finally, the proposed neuro-fuzzy system with novel differential evolution model is applied in chaotic sequence prediction problem. Results of this paper demonstrate the effectiveness of the proposed model. © 2011 IEEE

    Involvement of the Cav3.2 T-type calcium channel in thalamic neuron discharge patterns

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Mice that have defects in their low-threshold T-type calcium channel (T-channel) genes show altered pain behaviors. The changes in the ratio of nociceptive neurons and the burst firing property of reticular thalamic (RT) and ventroposterior (VP) neurons in Cav3.2 knockout (KO) mice were studied to test the involvement of thalamic T-channel and burst firing activity in pain function.</p> <p>Results</p> <p>Under pentobarbital or urethane anesthesia, the patterns of tonic and burst firings were recorded in functionally characterized RT and VPL neurons of Cav3.2 KO mice. Many RT neurons were nociceptive (64% under pentobarbital anesthesia and 50% under urethane anesthesia). Compared to their wild-type (WT) controls, fewer nociceptive RT neurons were found in Cav3.2 KO mice. Both nociceptive and tactile RT neurons showed fewer bursts in Cav3.2 KO mice. Within a burst, RT neurons of Cav3.2 KO mice had a lower spike frequency and less-prominent accelerando-decelerando change. In contrast, VP neurons of Cav3.2 KO mice showed a higher ratio of bursts and a higher discharge rate within a burst than those of the WT control. In addition, the long-lasting tonic firing episodes in RT neurons of the Cav3.2 KO had less stereotypic regularity than their counterparts in WT mice.</p> <p>Conclusions</p> <p>RT might be important in nociception of the mouse. In addition, we showed an important role of Cav3.2 subtype of T-channel in RT burst firing pattern. The decreased occurrence and slowing of the bursts in RT neurons might cause the increased VP bursts. These changes would be factors contributing to alternation of pain behavior in the Cav3.2 KO mice.</p
    corecore