1,017 research outputs found
Equivalence of Bose-Einstein condensation and symmetry breaking
Based on a classic paper by Ginibre [Commun. Math. Phys. {\bf 8} 26 (1968)]
it is shown that whenever Bogoliubov's approximation, that is, the replacement
of a_0 and a_0^* by complex numbers in the Hamiltonian, asymptotically yields
the right pressure, it also implies the asymptotic equality of ||^2/V and
/V in symmetry breaking fields, irrespective of the existence or
absence of Bose-Einstein condensation. Because the former was proved by Ginibre
to hold for absolutely integrable superstable pair interactions, the latter is
equally valid in this case. Apart from Ginibre's work, our proof uses only a
simple convexity inequality due to Griffiths.Comment: An error in my summary of previous results (the definition of F') is
corrected. The correction is to be done also in the PR
Many-particle quantum graphs and Bose-Einstein condensation
In this paper we propose quantum graphs as one-dimensional models with a
complex topology to study Bose-Einstein condensation and phase transitions in a
rigorous way. We fist investigate non-interacting many-particle systems on
quantum graphs and provide a complete classification of systems that exhibit
Bose-Einstein condensation. We then consider models of interacting particles
that can be regarded as a generalisation of the well-known Tonks-Girardeau gas.
Here our principal result is that no phase transitions occur in bosonic systems
with repulsive hardcore interactions, indicating an absence of Bose-Einstein
condensation
Study of a high spatial resolution 10B-based thermal neutron detector for application in neutron reflectometry: the Multi-Blade prototype
Although for large area detectors it is crucial to find an alternative to
detect thermal neutrons because of the 3He shortage, this is not the case for
small area detectors. Neutron scattering science is still growing its
instruments' power and the neutron flux a detector must tolerate is increasing.
For small area detectors the main effort is to expand the detectors'
performances. At Institut Laue-Langevin (ILL) we developed the Multi-Blade
detector which wants to increase the spatial resolution of 3He-based detectors
for high flux applications. We developed a high spatial resolution prototype
suitable for neutron reflectometry instruments. It exploits solid 10B-films
employed in a proportional gas chamber. Two prototypes have been constructed at
ILL and the results obtained on our monochromatic test beam line are presented
here
Proof of Bose-Einstein Condensation for Interacting Gases with a One-Particle Spectral Gap
Using a specially tuned mean-field Bose gas as a reference system, we
establish a positive lower bound on the condensate density for continuous Bose
systems with superstable two-body interactions and a finite gap in the
one-particle excitations spectrum, i.e. we prove for the first time standard
homogeneous Bose-Einstein condensation for such interacting systems
Anomalous fluctuations of the condensate in interacting Bose gases
We find that the fluctuations of the condensate in a weakly interacting Bose
gas confined in a box of volume follow the law . This anomalous behaviour arises from the occurrence of infrared
divergencies due to phonon excitations and holds also for strongly correlated
Bose superfluids. The analysis is extended to an interacting Bose gas confined
in a harmonic trap where the fluctuations are found to exhibit a similar
anomaly.Comment: 4 pages, RevTe
THERMODYNAMICS OF A BROWNIAN BRIDGE POLYMER MODEL IN A RANDOM ENVIRONMENT
We consider a directed random walk making either 0 or moves and a
Brownian bridge, independent of the walk, conditioned to arrive at point on
time . The Hamiltonian is defined as the sum of the square of increments of
the bridge between the moments of jump of the random walk and interpreted as an
energy function over the bridge connfiguration; the random walk acts as the
random environment. This model provides a continuum version of a model with
some relevance to protein conformation. The thermodynamic limit of the specific
free energy is shown to exist and to be self-averaging, i.e. it is equal to a
trivial --- explicitly computed --- random variable. An estimate of the
asymptotic behaviour of the ground state energy is also obtained.Comment: 20 pages, uuencoded postscrip
Gaussian field theories, random Cantor sets and multifractality
The computation of multifractal scaling properties associated with a critical
field theory involves non-local operators and remains an open problem using
conventional techniques of field theory. We propose a new description of
Gaussian field theories in terms of random Cantor sets and show how universal
multifractal scaling exponents can be calculated. We use this approach to
characterize the multifractal critical wave function of Dirac fermions
interacting with a random vector potential in two spatial dimensions. We show
that the multifractal scaling exponents are self-averaging.Comment: Extensive modifications of previous version; exact results replace
numerical calculation
Deep subcutaneous application of poly-L-lactic acid as a filler for facial lipoatrophy in HIV-infected patients
Introduction: Facial lipoatrophy is a crucial problem of HIV-infected patients undergoing highly active antiretroviral therapy (HAART). Poly-L-lactic acid (PLA), provided as New-Fill(R)/Sculptra(TM), is known as one possible treatment option. In 2004 PLA was approved by the FDA as Sculptra(TM) for the treatment of lipoatrophy of the face in HIV-infected patients. While the first trials demonstrated relevant efficacy, this was to some extent linked to unwanted effects. As the depth of injection was considered relevant in this context, the application modalities of the preparation were changed. The preparation was to be injected more deeply into subcutaneous tissue, after increased dilution. Material and Methods: To test this approach we performed a pilot study following the new recommendations in 14 patients. Results: While the efficacy turned out to be about the same, tolerability was markedly improved. The increase in facial dermal thickness was particularly obvious in those patients who had suffered from lipoatrophy for a comparatively small period of time. Conclusion: With the new recommendations to dilute PLA powder and to inject it into the deeper subcutaneous tissue nodule formation is a minor problem. However, good treatment results can only be achieved if lipoatrophy is not too intense; treatment intervals should be about 2 - 3 weeks. Copyright (C) 2005 S. Karger AG, Basel
Some Restrictions Abroad Affecting Corporations
A neutron detector concept based on solid layers of boron carbide enriched in 1 B has been in development for the last few years as an alternative for He-3 by collaboration between the ILL, ESS and Linkoping University. This Multi-Grid detector uses layers of aluminum substrates coated with (B4C)-B-10 on both sides that are traversed by the incoming neutrons. Detection is achieved using a gas counter readout principle. By segmenting the substrate and using multiple anode wires, the detector is made inherently position sensitive. This development is aimed primarily at neutron scattering instruments with large detector areas, such as time-of-flight chopper spectrometers. The most recent prototype has been built to be interchangeable with the He-3 detectors of IN6 at ILL. The 1 B detector has an active area of 32 x 48 cm(2). It was installed at the IN6 instrument and operated for several weeks, collecting data in parallel with the regularly scheduled experiments, thus providing the first side-by-side comparison with the conventional He-3 detectors. Results include an efficiency comparison, assessment of the in-detector scattering contribution, sensitivity to gamma-rays and the signal-to-noise ratio in time-of-flight spectra. The good expected performance has been confirmed with the exception of an unexpected background count rate. This has been identified as natural alpha activity in aluminum. New convertor substrates are under study to eliminate this source of background
6-thioguanine treatment in inflammatory bowel disease: A critical appraisal by a European 6-TG working party
Recently, the suggestion to use 6-thioguanine (6-TG) as an alternative thiopurine in patients with inflammatory bowel disease (IBD) has been discarded due to reports about possible (hepato) toxicity. During meetings arranged in Vienna and Prague in 2004, European experts applying 6-TG further on in IBD patients presented data on safety and efficacy of 6-TG. After thorough evaluation of its risk-benefit ratio, the group consented that 6-TG may still be considered as a rescue drug in stringently defined indications in IBD, albeit restricted to a clinical research setting. As a potential indication for administering 6-TG, we delineated the requirement for maintenance therapy as well as intolerance and/or resistance to aminosalicylates, azathioprine, 6-mercaptopurine, methotrexate and infliximab. Furthermore, indications are preferred in which surgery is thought to be inappropriate. The standard 6-TG dosage should not exceed 25 mg daily. Routine laboratory controls are mandatory in short intervals. Liver biopsies should be performed after 6-12 months, three years and then three-yearly accompanied by gastroduodenoscopy, to monitor for potential hepatotoxicity, including nodular regenerative hyperplasia (NRH) and veno-occlusive disease (VOD). Treatment with 6-TG must be discontinued in case of overt or histologically proven hepatotoxicity. Copyright (c) 2006 S. Karger AG, Basel
- …
