1,814 research outputs found

    Evidence for virtual Compton scattering from the proton

    Get PDF
    In virtual Compton scattering an electron is scattered off a nucleon such that the nucleon emits a photon. We show that these events can be selected experimentally, and present the first evidence for virtual Compton scattering from the proton in data obtained at the Stanford Linear Accelerator Center. The angular and energy dependence of the data is well described by a calculation that includes the coherent sum of electron and proton radiation

    Home measures of anxiety, avoidant coping and defence as predictors of anxiety, heart rate and skin conductance level just before invasive cardiovascular procedures

    Get PDF
    The question was whether anxiety, heart rate and skin conductance level just before invasive cardiac procedures could be predicted by anxiety related measures obtained at patients homes approximately 3 weeks before treatment. Trait measures of avoidant coping and defence were provided by sixty-three male and thirty-three female patients who were scheduled for a diagnostic or interventional heart catheterization. In hospital physiological measures were registered continously during a 20 min interview and subsequently patients reported their anxiety. Results with hierarchical regres

    Interventional Cardiology in Europe 1993

    Get PDF
    An annual survey on cardiac interventions in Europe is performed by the working group on Coronary Circulation of the European Society of Cardiology with the help of the national societies of cardiology. A questionnaire about cardiac interventions in 1993 was mailed to a representative of the national societies of 35 members of the European Society of Cardiology. The data collection of coronary interventions was delayed by slow backreporting and from 10 of the 35 national members data were missing or grossly incomplete. They were excluded from the analysis. Coronary anglography A total of 756 822 coronary angiograms were reported resulting in an incidence of 1146 ± 1024 per 106 inhabitants, ranging from 24 (Romania) to 3499 (Germany). This represents an increase of 12% compared to 1992. Germany (279 882 cases), France (157 237), the United Kingdom (77 000), Italy (44 934) and Spain (37 591) registered 79% of all the coronary angiograms performed. Percutaneous transluminal coronary angioptasty A total of 183 728 percutaneous transluminal coronary angioplasty cases were reported in 1993, 24% more than in 1992. On average, they accounted for 18 ± 7% (range 8 (Romania) to 35% (Sweden)) of the coronary angiograms. Most of these percutaneous transluminal coronary angioplasties (82%) were confined to a single vessel. In 13% only, percutaneous transluminal coronary angioplasty took place immediately after the diagnostic study. Adjusted per capita, Germany ranks first with 873 percutaneous transluminal coronary angioplasties per 106 inhabitants, followed by France (737), Holland (725), Belgium (713), and Switzerland (665). The European mean of percutaneous transluminal coronary angioplasties per 106 inhabitants was 270 ± 279, representing an increase of 14% compared with 1992. A major in-hospital complication was reported in 3.8% of the patients undergoing percutaneous transluminal coronary angioplasty: 0.6% hospital deaths, 1.5% emergency coronary artery bypass graftings, and 1.7% myocardial infarctions. New devices In 1993 stents were implanted in 6444 patients (3.5% of all percutaneous transluminal coronary angioplasty patients), equally distributed between bail-out situations (53%) and elective procedures. The 14 stent implanting countries showed a mean increase in the incidence of coronary stenting of 53% compared with 1992. Other interventional devices were applied in 7045 cases, i.e. 3.8% of all percutaneous transluminal coronary angioplasty cases. Coronary ultrasound (2194 cases) and coronary angioscopy (380 cases) were performed infrequently. Non-coronary interventions Valvuloplasties were the most frequently performed non-coronary interventions. Six European countries performed more than 300 valvuloplasties each in 1993. Most of them were mitral valvuloplasties in southern countries. Conclusions Although partial backreporting might bias conclusions, several findings of this survey are noteworthy for the participating countries: The number of percutaneous transluminal coronary angioplasties is universally increasing. There is an extremely wide range of coronary angiography and percutaneous transluminal coronary angioplasties performed per population. The most common additional procedure is a stent implantation while other new devices are only rarely applied. Mitral valvuloplasty is the most frequently performed non-coronary intervention. (Eur Heart J 1996; 17: 1318-1328

    Improving the sensitivity of future GW observatories in the 1-10 Hz band: Newtonian and seismic noise

    Get PDF
    The next generation gravitational wave interferometric detectors will likely be underground detectors to extend the GW detection frequency band to frequencies below the Newtonian noise limit. Newtonian noise originates from the continuous motion of the Earth’s crust driven by human activity, tidal stresses and seismic motion, and from mass density fluctuations in the atmosphere. It is calculated that on Earth’s surface, on a typical day, it will exceed the expected GW signals at frequencies below 10 Hz. The noise will decrease underground by an unknown amount. It is important to investigate and to quantify this expected reduction and its effect on the sensitivity of future detectors, to plan for further improvement strategies. We report about some of these aspects. Analytical models can be used in the simplest scenarios to get a better qualitative and semi-quantitative understanding. As more complete modeling can be done numerically, we will discuss also some results obtained with a finite-element-based modeling tool. The method is verified by comparing its results with the results of analytic calculations for surface detectors. A key point about noise models is their initial parameters and conditions, which require detailed information about seismic motion in a real scenario. We will describe an effort to characterize the seismic activity at the Homestake mine which is currently in progress. This activity is specifically aimed to provide informations and to explore the site as a possible candidate for an underground observatory. Although the only compelling reason to put the interferometer underground is to reduce the Newtonian noise, we expect that the more stable underground environment will have a more general positive impact on the sensitivity.We will end this report with some considerations about seismic and suspension noise

    Enhanced Radiation Hardness and Faster Front Ends for the Beetle Readout Chip

    Get PDF
    This paper summarizes the recent progress in the development of the 128 channel pipelined readout chip Beetle, which is intended for the silicon vertex detector, the inner tracker, the pile-up veto trigger and the RICH detectors of LHCb. Deficiencies found in the front end of the Beetle Version 1.0 and 1.1 chips resulted in the submissions of BeetleFE 1.1 and BeetleFE 1.2, while BeetleSR 1.0 implements test circuits to provide future Beetle chips with logic circuits hardened against single event upset (SEU). Section I. motivates the development of new front ends for the Beetle chip, and section II. summarizes their concepts and construction. Section III. reports preliminary results from the BeetleFE 1.1 and BeetleFE 1.2 chips, while section IV. describes the BeetleSR 1.0 chip. An outlook on future test and development of the Beetle chip is given in section V
    corecore