681 research outputs found

    Solar Irradiance Variability is Caused by the Magnetic Activity on the Solar Surface

    Full text link
    The variation in the radiative output of the Sun, described in terms of solar irradiance, is important to climatology. A common assumption is that solar irradiance variability is driven by its surface magnetism. Verifying this assumption has, however, been hampered by the fact that models of solar irradiance variability based on solar surface magnetism have to be calibrated to observed variability. Making use of realistic three-dimensional magnetohydrodynamic simulations of the solar atmosphere and state-of-the-art solar magnetograms from the Solar Dynamics Observatory, we present a model of total solar irradiance (TSI) that does not require any such calibration. In doing so, the modeled irradiance variability is entirely independent of the observational record. (The absolute level is calibrated to the TSI record from the Total Irradiance Monitor.) The model replicates 95% of the observed variability between April 2010 and July 2016, leaving little scope for alternative drivers of solar irradiance variability at least over the time scales examined (days to years).Comment: Supplementary Materials; https://journals.aps.org/prl/supplemental/10.1103/PhysRevLett.119.091102/supplementary_material_170801.pd

    Auto-oscillation threshold, narrow spectral lines, and line jitter in spin-torque oscillators based on MgO magnetic tunnel junctions

    Full text link
    We demonstrate spin torque induced auto-oscillation in MgO-based magnetic tunnel junctions. At the generation threshold, we observe a strong line narrowing down to 6 MHz at 300K and a dramatic increase in oscillator power, yielding spectrally pure oscillations free of flicker noise. Setting the synthetic antiferromagnet into autooscillation requires the same current polarity as the one needed to switch the free layer magnetization. The induced auto-oscillations are observed even at zero applied field, which is believed to be the acoustic mode of the synthetic antiferromagnet. While the phase coherence of the auto-oscillation is of the order of microseconds, the power autocorrelation time is of the order of milliseconds and can be strongly influenced by the free layer dynamics

    Auto-oscillation threshold and line narrowing in MgO-based spin-torque oscillators

    Full text link
    We present an experimental study of the power spectrum of current-driven magnetization oscillations in MgO tunnel junctions under low bias. We find the existence of narrow spectral lines, down to 8 MHz in width at a frequency of 10.7 GHz, for small applied fields with clear evidence of an auto-oscillation threshold. Micromagnetics simulations indicate that the excited mode corresponds to an edge mode of the synthetic antiferromagnet

    The ACCOMPLISH study. A cluster randomised trial on the cost-effectiveness of a multicomponent intervention to improve hand hygiene compliance and reduce healthcare associated infections

    Get PDF
    Contains fulltext : 97410.pdf (publisher's version ) (Open Access)BACKGROUND: Public health authorities have recognized lack of hand hygiene in hospitals as one of the important causes of preventable mortality and morbidity at population level. The implementation strategy ACCOMPLISH (Actively Creating COMPLIance Saving Health) targets both individual and environmental determinants of hand hygiene. This study aims to evaluate the cost-effectiveness of a multicomponent implementation strategy aimed at the reduction of healthcare associated infections in Dutch hospital care, by promotion of hand hygiene. METHODS/DESIGN: The ACCOMPLISH package will be evaluated in a two-arm cluster randomised trial in 16 hospitals in the Netherlands, in one intensive care unit and one surgical ward per hospital. INTERVENTION: A multicomponent package, including e-learning, team training, introduction of electronic alcohol based hand rub dispensers and performance feedback. VARIABLES: The primary outcome measure will be the observed hand hygiene compliance rate, measured at baseline and after 6, 12 and 18 months; as a secondary outcome measure the prevalence of healthcare associated infections will be measured at the same time points. Process indicators of the intervention will be collected pre and post intervention. An ex-post economic evaluation of the ACCOMPLISH package from a healthcare perspective will be performed. STATISTICAL ANALYSIS: Multilevel analysis, using mixed linear modelling techniques will be conducted to assess the effect of the intervention strategy on the overall compliance rate among healthcare workers and on prevalence of healthcare associated infections. Questionnaires on process indicators will be analysed with multivariable linear regression, and will include both behavioural determinants and determinants of innovation. Cost-effectiveness will be assessed by calculating the incremental cost-effectiveness ratio, defined here as the costs for the intervention divided by the difference in prevalence of healthcare associated infections between the intervention and control group. DISCUSSION: This study is the first RCT to investigate the effects of a hand hygiene intervention programme on the number of healthcare associated infections, and the first to investigate the cost-effectiveness of such an intervention. In addition, if the ACCOMPLISH package proves successful in improving hand hygiene compliance and lowering the prevalence of healthcare associated infections, the package could be disseminated at (inter)national level. TRIAL REGISTRATION: NTR2448

    Transverse component of the magnetic field in the solar photosphere observed by Sunrise

    Full text link
    We present the first observations of the transverse component of photospheric magnetic field acquired by the imaging magnetograph Sunrise/IMaX. Using an automated detection method, we obtain statistical properties of 4536 features with significant linear polarization signal. Their rate of occurrence is 1-2 orders of magnitude larger than values reported by previous studies. We show that these features have no characteristic size or lifetime. They appear preferentially at granule boundaries with most of them being caught in downflow lanes at some point in their evolution. Only a small percentage are entirely and constantly embedded in upflows (16%) or downflows (8%).Comment: Accepted for the Sunrise Special Issue of ApJ

    Sextupole correction magnets for the Large Hadron Collider

    Get PDF
    About 2500 superconducting sextupole corrector magnets (MCS) are needed for the Large Hadron Collider (LHC) at CERN to compensate persistent current sextupole fields of the main dipoles. The MCS is a cold bore magnet with iron yoke. The coils are made from a NbTi conductor, which is cooled to 1.9 K. In the original CERN design 6 individual sub-coils, made from a monolithic composite conductor, are assembled and spliced together to form the sextupole. The coils are individually wound around precision-machined central islands and stabilized with matching saddle pieces at both ends. The Advanced Magnet Lab, Inc. (AML) has produced an alternative design, which gives improved performance and reliability at reduced manufacturing cost. In the AML design, the magnet consists of three splice-free sub-coils, which are placed with an automated winding process into pockets of prefabricated G-11 support cylinders. Any assembly process of sub-coils with potential misalignment is eliminated. The AML magnet uses a Kapton-wrapped mini-cable, which allows helium penetration into the vicinity of the conductor, increasing its cryogenic stability. Eliminating all internal splices from the magnet significantly reduces heat loads and the risk of magnet failure during operation. A tested prototype reached the critical current limit of the conductor in the first quench. (3 refs)

    A comparison of different methods for assessing leaf area index in four canopy types

    Get PDF
    The agreement of Leaf Area Index (LAI) assessments from three indirect methods, i.e. the LAI–2200 Plant Canopy Analyzer, the SS1 SunScan Canopy Analysis System and Digital Hemispherical Photography (DHP) was evaluated for four canopy types, i.e. a short rotation coppice plantation (SRC) with poplar, a Scots pine stand, a Pedunculate oak stand and amaize field. In the SRC and in the maize field, the indirect measurements were compared with direct measurements (litter fall and harvesting). In the low LAI range (0 to 2) the discrepancies of the SS1 were partly explained by the inability to properly account for clumping and the uncertainty of the ellipsoidal leaf angle distribu tion parameter. The higher values for SS1 in the medium (2 to 6) to high (6 to 8) ranges might be explained by gap fraction saturation for LAI–2200 and DHP above certain values. Wood area index –understood as the woody light blocking elements from the canopy with respect to diameter growth– accounted for overestimation by all indirect methods when compared to direct methods in the SRC. The inter-comparison of the three indirect methods in the four canopy types showed a general agreement for all methods in the medium LAI range (2 to 6). LAI–2200 and DHP revealed the best agreement among the indirect methods along the entire range of LAI (0 to 8) in all canopy types. SS1 showed some discrepancies with the LAI–2200 and DHP at low (0 to 2) and high ranges of LAI (6 to 8

    A Preference for Contralateral Stimuli in Human Object- and Face-Selective Cortex

    Get PDF
    Visual input from the left and right visual fields is processed predominantly in the contralateral hemisphere. Here we investigated whether this preference for contralateral over ipsilateral stimuli is also found in high-level visual areas that are important for the recognition of objects and faces. Human subjects were scanned with functional magnetic resonance imaging (fMRI) while they viewed and attended faces, objects, scenes, and scrambled images in the left or right visual field. With our stimulation protocol, primary visual cortex responded only to contralateral stimuli. The contralateral preference was smaller in object- and face-selective regions, and it was smallest in the fusiform gyrus. Nevertheless, each region showed a significant preference for contralateral stimuli. These results indicate that sensitivity to stimulus position is present even in high-level ventral visual cortex

    Assessment of correlates of hand hygiene compliance among final year medical students: a cross-sectional study in the Netherlands

    Get PDF
    OBJECTIVES: To identify the factors that influence the hand hygiene compliance of final year medical students, using a theoretical behavioural framework. DESIGN: Cross-sectional survey assessing self-reported compliance and its behavioural correlates. SETTING: Internships of medical students in the Netherlands. PARTICIPANTS: 322 medical students of the Erasmus Medical Center were recruited over a period of 12 months during the Public Health internship, which is the final compulsory internship after an 18-month rotation schedule in all major specialities. PRIMARY AND SECONDARY OUTCOME MEASURES: Behavioural factors influencing compliance to hand hygiene guidelines were measured by means of a questionnaire based on the Theory of Planned Behaviour and Social Ecological Models. Multiple lin
    • …
    corecore