110 research outputs found

    A new window of opportunity for TAVI

    Get PDF
    This short report features the role of multi detector computer tomography (MDCT) in imaging the ascending aorta to assess the feasibility of a transaortic access route for transcatheter placement of an Edwards SAPIEN XTTM aortic valve

    Perspective Chapter: Valve-in-Valve Transcatheter Aortic Valve Replacement (ViV) for Failed Bioprosthetic Valves

    Get PDF
    Aortic valve disease remains the second most common valvular heart disease worldwide. Surgical aortic valve replacement (SAVR) with mechanical or bioprosthetic valves and transcatheter aortic valve replacement (TAVR) with bioprosthetic valves are both approved therapies for patients with severe aortic stenosis (AS) across all surgical risk categories. On the other hand, SAVR remains the mainstay of treatment for severe aortic regurgitation (AR) with TAVR reserved for selected patients at prohibitive surgical risk. Both surgical and transcatheter bioprosthetic valves are prone to bioprosthetic valve failure (BVF) due to various etiologies, and can lead to restenosis, regurgitation, or a combination of both. BVF can now be addressed by repeat valve replacement whether surgical or valve-in-valve TAVR (ViV). ViV is a desirable option for elderly patients at high surgical risk and requires meticulous planning with pre-operative CT imaging to optimize outcomes and minimize complications

    Transaortic transcatheter aortic valve implantation - rationale and design of the multicenter, multinational prospective ROUTE registry

    Get PDF
    Transaortic transcatheter aortic valve implantation (TAo-TAVI) is a recently developed approach that provides an alternative delivery route for valve replacement in patients with vascular abnormalities or existing comorbidities. While initial studies have shown the principal efficacy and safety, the real world effectiveness and safety of this approach remains to be fully assessed. In this regard, the Registry Of the Utilization of the TAo-TAVI approach using the Edwards SAPIEN Valve (ROUTE) represents the first multicenter, multinational prospective documentation of the course and outcome of patients with severe calcific aortic stenosis (AS) undergoing TAo-TAVI. ROUTE commenced in February 2013 with the goal of consecutively enrolling 300 patients at up to 22 sites across Europe. The primary objective of ROUTE is to determine the 30-day mortality associated with TAo-TAVI using the Edwards SAPIEN THV (Edwards Lifesciences, Irvine, CA). In addition, ROUTE aims to quantify complications, predictors of patient outcome and the value of CT guided valve sizing. Findings from this landmark registry will provide important information regarding procedural success rates and early mortality in patients undergoing TAo-TAVI. Identifier: NCT0199143

    Neo-LVOT and Transcatheter Mitral Valve Replacement: Expert Recommendations

    Get PDF
    With the advent of transcatheter mitral valve replacement (TMVR), the concept of the neo-left ventricular outflow tract (LVOT) was introduced and remains an essential component of treatment planning. This paper describes the LVOT anatomy and provides a step-by-step computed tomography methodology to segment and measure the neo-LVOT while discussing the current evidence and outstanding challenges. It also discusses the technical and hemodynamic factors that play a major role in assessing the neo-LVOT. A summary of expert-based recommendations about the overall risk of LVOT obstruction in different scenarios is presented along with the currently available methods to reduce the risk of LVOT obstruction and other post-procedural complications

    Transcatheter Valve Implantation in Failed Surgically Inserted Bioprosthesis Review and Practical Guide to Echocardiographic Imaging in Valve-in-Valve Procedures

    Get PDF
    AbstractAn increased use of bioprosthetic heart valves has stimulated an interest in possible transcatheter options for bioprosthetic valve failure given the high operative risk. The encouraging results of transcatheter aortic valve implantation in high-risk surgical candidates with native disease have led to the development of the transcatheter valve-in-valve (VIV) procedures for failed bioprostheses. VIV procedures are unique in many ways, and there is an increased need for multimodality imaging in a team-based approach. The echocardiographic approach to VIV procedures has not previously been described. In this review, we summarize key echocardiographic requirements for optimal patient selection, procedural guidance, and immediate post-procedural assessment for VIV procedures

    Transcatheter Aortic Valve Replacement Using Transaortic Access

    Get PDF
    OBJECTIVES The Registry of the Utilization of the TAo-TAVR approach using the Edwards SAPIEN Valve (ROUTE) was established to assess the effectiveness and safety of the use of transaortic (TAo) access for transcatheter aortic valve replacement (TAVR) procedures (NCT01991431). BACKGROUND TAVR represents an alternative to surgical valve replacement in high-risk patients. Whereas the transfemoral access route is used commonly as the first-line approach, transapical access is an option for patients not suitable for transfemoral treatment mainly due to anatomic conditions. TAo-TAVR has been shown to be a viable alternative surgical access route; however, only limited data on its effectiveness and safety has been published. METHODS ROUTE is a multicenter, international, prospective, observational registry; data were collected from 18 centers across Europe starting in February 2013. Patients having severe calcific aortic stenosis were documented if they were scheduled to undergo TAo-TAVR using an Edwards SAPIEN XT or a SAPIEN 3 valve. The primary endpoint was 30-day mortality. Secondary endpoints were intraprocedural or in hospital and 30-day complication rates. RESULTS A total of 301 patients with a mean age of 81.7 +/- 5.9 years and an Society of Thoracic Surgeons score of 9.0 +/- 7.6% were included. Valve success was documented in 96.7%. The 30-day mortality was 6.1% (18/293) (procedure-related mortality: 3.1%; 9 of 293). The Valve Academic Research Consortium-2 defined complications included myocardial infarction (1.0%), stroke (1.0%), transient ischemic attack (0.3%), major vascular complications (3.4%), life-threatening bleeding (3.4%), and acute kidney injury (9.5%). In 3.3% of patients, paravalvular regurgitation was classified as moderate or severe (10 of 300). Twenty-six patients (8.8%) required permanent pacemaker implantation. CONCLUSIONS TAo access for TAVR seems to be a safe alternative to the transapical procedure. (C) 2016 by the American College of Cardiology Foundation.Peer reviewe

    Balloon-expandable transaortic transcatheter aortic valve implantation with or without predilation

    Get PDF
    Objective: It has been reported that balloon aortic valvuloplasty immediately before transfemoral or transapical transcatheter aortic valve implantation has mostly little to no clinical value. We aimed to provide data on the need for balloon aortic valvuloplasty in patients undergoing transaortic transcatheter aortic valve implantation. Methods: Patients undergoing transaortic transcatheter aortic valve implantation with the Edwards SAPIEN XT (Nyon, Switzerland) or 3 transcatheter heart valve were prospectively included at 18 sites across Europe. In the present analysis, we compare the periprocedural and 30-day outcomes of patients undergoing conventional (thorn balloon aortic valvuloplasty) versus direct (-balloon aortic valvuloplasty) transaortic transcatheter aortic valve implantation. Results: Of the 300 patients enrolled, 222 underwent conventional and 78 underwent direct transaortic transcatheter aortic valve implantation. Peak and mean transvalvular gradients were improved in both groups with no significant difference between groups. Procedural duration, contrast agent volume, and requirement for postdilation were also comparable. A trend toward fewer periprocedural complications was evident in the direct group (3.9% vs 11.3%; P = .053), with significantly lower rates of permanent pacemaker implantation (0% vs 5.0%; P = .034). Balloon aortic valvuloplasty omission had no significant effect on any of the 30-day safety and efficacy outcomes, including Valve Academic Research Consortium-2 composite end points (early safety events: 22.7% vs 17.4%, odds ratio, 1.17, 95% confidence interval, 0.53-2.62; clinical efficacy events: 20.5% vs 18.7%, odds ratio, 1.14, 95% confidence interval, 0.51-2.55). Conclusions: For many patients, balloon aortic valvuloplasty predilation seems to have little clinical value in transaortic transcatheter aortic valve implantation using a balloon expandable transcatheter valve and may result in a higher rate of periprocedural complications, particularly in terms of permanent pacemaker implantation.Peer reviewe

    Transaortic transcatheter aortic valve implantation as a first-line choice or as a last resort? An analysis based on the ROUTE registry

    Get PDF
    OBJECTIVES: Transaortic transcatheter aortic valve implantation (TAo-TAVI) is a recently developed alternative to transapical (TA) or transfemoral (TF) TAVI. We aimed to analyse the effectiveness and safety of TAo-TAVI as a first line approach and to compare it to patients receiving TAo-TAVI as a last resort, which is current practice. METHODS: ROUTE is a prospective, multicentre registry to assess the clinical outcomes of TAo-TAVI. Patients without contraindications for TA-and TF-TAVI (TAo-first) were compared to patients with contraindications for both of these access routes (TAo-last). Outcome analysis was based on VARC II defined clinical end-points. RESULTS: Three hundred and one patients were included, of which 224 patients met TAo-first and 77 TAo-last criteria. The valve was delivered and catheter retrieved successfully in all patients. In the TAo-first group, rates of conversion to open surgery and requirement for a second valve were low and not different compared to TAo-last patients (1% vs. 3%, P = 0.46 and 1% vs. 3%, P = 0.46, respectively). This was also true for the rate of paravalvular regurgitation (>= moderate: 4% vs. 3%). All-cause mortality at 30-days was 6% vs. 5% (P = 0.76), rates of stroke 2% vs. 0% (P = 0.24), pacemaker implantation (11% vs. 4%, P = 0.093), and life-threatening bleeding 4% vs. 3% (P = 0.70). Valve safety (both 85%, P = 0.98) and clinical efficacy (80% vs. 82%; P = 0.73) did not differ between groups. CONCLUSIONS: Although comparative data to TA and TF procedures were not available in the present analysis, findings suggest that TAo may be considered not only as a last resort strategy when classical access routes are deemed unfeasible, but also as a potential first-line option, with only low rates of paravalvular regurgitation and permanent pacemaker implantation.Peer reviewe

    Prospective Study of TMVR Using Balloon-Expandable Aortic Transcatheter Valves in MAC: MITRAL Trial 1-Year Outcomes

    Get PDF
    OBJECTIVES: The aim of this study was to evaluate 1-year outcomes of valve-in-mitral annular calcification (ViMAC) in the MITRAL (Mitral Implantation of Transcatheter Valves) trial. BACKGROUND: The MITRAL trial is the first prospective study evaluating the feasibility of ViMAC using balloon-expandable aortic transcatheter heart valves. METHODS: A multicenter prospective study was conducted, enrolling high-risk surgical patients with severe mitral annular calcification and symptomatic severe mitral valve dysfunction at 13 U.S. sites. RESULTS: Between February 2015 and December 2017, 31 patients were enrolled (median age 74.5 years [interquartile range (IQR): 71.3 to 81.0 years], 71% women, median Society of Thoracic Surgeons score 6.3% [IQR: 5.0% to 8.8%], 87.1% in New York Heart Association functional class III or IV). Access was transatrial (48.4%), transseptal (48.4%), or transapical (3.2%). Technical success was 74.2%. Left ventricular outflow tract obstruction (LVOTO) with hemodynamic compromise occurred in 3 patients (transatrial, n = 1; transseptal, n = 1; transapical, n = 1). After LVOTO occurred in the first 2 patients, pre-emptive alcohol septal ablation was implemented to decrease risk in high-risk patients. No intraprocedural deaths or conversions to open heart surgery occurred during the index procedures. All-cause mortality at 30 days was 16.7% (transatrial, 21.4%; transseptal, 6.7%; transapical, 100% [n = 1]; p = 0.33) and at 1 year was 34.5% (transatrial, 38.5%; transseptal, 26.7%; p = 0.69). At 1-year follow-up, 83.3% of patients were in New York Heart Association functional class I or II, the median mean mitral valve gradient was 6.1 mm Hg (IQR: 5.6 to 7.1 mm Hg), and all patients had ≤1+ mitral regurgitation. CONCLUSIONS: At 1 year, ViMAC was associated with symptom improvement and stable transcatheter heart valve performance. Pre-emptive alcohol septal ablation may prevent transcatheter mitral valve replacement-induced LVOTO in patients at risk. Thirty-day mortality of patients treated via transseptal access was lower than predicted by the Society of Thoracic Surgeons score. Further studies are needed to evaluate safety and efficacy of ViMAC

    Transaortic access is the key to success

    No full text
    corecore