71 research outputs found

    Incidentes y eventos adversos en usuarios de sonda enteral : alerta a partir de una cohorte

    Get PDF
    Introduction: few studies clearly describe incidents or adverse events that occur during the enteral nutrition process, which hinders the identification of critical points. Objective: to describe breaches of protocol, incidents and adverse events, during the period beginning with indications until the use of enteral feeding tube in an Emergency Department. Method: trained nurses prospectively monitored a cohort of adults in a Brazilian Emergency Department where use of enteral feeding tube was indicated and up to their use. The study sought to identify breaches of protocol, such as verbal orders to insert feeding tubes, or authorization of their use without X-rays to confirm the position of the feeding tubes. Incidents were characterized as events that could have caused harm to patients, while adverse events were those that did actually cause harm. The study was approved by the institution’s Research Ethics Committee. Results: in 150 feeding tube insertions, there were 169 breaches of protocol: verbal orders for feeding tube insertion (n = 59); no X-rays taken (n = 11); and no examination of the X-rays by physicians (n = 12). There were 30 incidents: unintentional removal of the feeding tube (n = 23); and administration of enteral nutrition after breach of preventive barriers. There was one adverse event: aspiration of enteral nutrition. Conclusion: there was a high frequency of breaches of safety protocols; many developed into incidents, and one resulted in an adverse event.Introducción: pocos estudios describen claramente los incidentes o eventos adversos que suceden durante el proceso de nutrición enteral, dificultando la identificación de puntos críticos. Objetivo: describir las rupturas de protocolo, los incidentes y los eventos adversos de la indicación para uso de sondas nasogástricas en un Servicio de Urgencias. Método: enfermeras capacitadas siguieron prospectivamente a una cohorte de adultos de un Servicio de Urgencias brasileño, con indicación de uso de sonda enteral. Se buscó identificar las rupturas de protocolo, descritas como: “orden verbal” para inserción de la sonda o para aprobar su uso; y no realización de radiografía confirmatoria del posicionamiento de la sonda. Los incidentes fueron considerados eventos que podrían haber provocado daños al paciente, mientras que los eventos adversos, como incidentes que efectivamente los provocaron. Este proyecto fue aprobado por el Comité de Ética en Investigación de la institución. Resultados: en 150 inserciones de sonda hubo 169 rupturas de protocolo: orden verbal para inserción de sonda (n = 59), no realización de radiografía (n = 11) y radiografía no evaluada por médico (n = 12). Ocurrieron 30 incidentes: retiro inadvertido de sonda (n = 23) y administración de dieta en vigencia de ruptura de barreras (n = 7). Hubo un evento adverso grave (aspiración de dieta). Conclusión: hubo elevada frecuencia de ruptura de protocolo de seguridad; muchas evolucionaron a incidentes y uno de ellos resultó evento adverso

    Incidência e tempo até a primeira tração ou obstrução da sonda nasoenteral em adultos hospitalizados

    Get PDF
    Objetivo: Determinar a incidência e o tempo até a primeira tração ou obstrução da sonda nasoenteral em adultos hospitalizados.Método: Dupla coorte prospectiva que incluiu 494 adultos usuários de sonda nasoenteral, internados em duas unidades clínicas e duas cirúrgicas de um hospital universitário. Os pacientes foram acompanhados diariamente quanto à ocorrência de trações ou obstruções da sonda, entre 2017 e 2019. O método de Kaplan-Meier foi utilizado para a estimação do tempo até a ocorrência do primeiro evento.Resultados: A tração de sonda ocorreu em 33% da amostra, e a incidência foi maior nos cinco primeiros dias de uso da sonda. A incidência de obstrução foi de 3,4%, e aumentou com otempo de uso da sonda.Conclusão: A incidência de tração é maior no início do uso, enquanto a incidência de obstrução aumenta com o tempo de usoda sondanasoenteral. Palavras-chave: Cuidados de enfermagem. Nutrição enteral. Intubação gastrointestinal. Segurança do paciente. Gestão de riscos. Administração dos cuidados ao paciente

    Incidencia y tiempo hasta la primera tracción u obstrucción de la sonda nasoenteral en adultos hospitalizados

    Get PDF
    Objetivo: Determinar a incidência e o tempo até a primeira tração ou obstrução da sonda nasoenteral em adultos hospitalizados. Método: Dupla coorte prospectiva que incluiu 494 adultos usuários de sonda nasoenteral, internados em duas unidades clínicas e duas cirúrgicas de um hospital universitário. Os pacientes foram acompanhados diariamente quanto à ocorrência de trações ou obstruções da sonda, entre 2017 e 2019. O método de Kaplan-Meier foi utilizado para a estimação do tempo até a ocorrência do primeiro evento. Resultados: A tração de sonda ocorreu em 33% da amostra, e a incidência foi maior nos cinco primeiros dias de uso da sonda. A incidência de obstrução foi de 3,4%, e aumentou com otempo de uso da sonda. Conclusão: A incidência de tração é maior no início do uso, enquanto a incidência de obstrução aumenta com o tempo de usoda sondanasoenteral.Objective: To determine incidence and time until first traction or obstruction of nasoenteral tube in hospitalized adults. Methods: Prospective double cohort study that included 494 adults who were users of nasoenteral tubes as inpatients in two clinical units and two surgical units in a teaching hospital. The occurrence of tube tractions and obstructions was monitored daily between 2017 and 2019. The Kaplan-Meier method was used to estimate time until the first event. Results: Tube traction occurred in 33% of the sample, and the incidence of the event was higher on the first five days of tube use. Tube obstruction incidence was 3.4% and grew as tube use time increased. Conclusion: Traction incidence was higher at the beginning of the period of use, whereas obstruction incidence grew as tube use time increased.Objetivo: Determinar la incidencia y el tiempo hasta la primera tracción u obstrucción de la sonda nasoenteral en adultos hospitalizados. Método: Doble cohorte prospectiva incluyendo a 494 adultos usuarios de sonda nasoenteral, internados en dos servicios clínicos y dos servicios quirúrgicos de hospital universitario. Los pacientes fueron seguidos diariamente respecto de ocurrencia de tracciones u obstrucciones de sonda, entre 2017 y 2019. Se utilizó el método de Kaplan-Meier para estimar el tiempo hasta la ocurrencia del primer evento. Resultados: El 33% de la muestra sufrió tracción de la sonda, la incidencia fue mayor en los cinco primeros días de uso de la misma. La incidencia de obstrucción fue del 3,4% y aumentó con el tiempo de uso de la sonda. Conclusión: La incidencia de tracción es mayor hacia el inicio de su uso, mientras que la incidencia de la obstrucción aumenta con el tiempo de uso de la sonda nasoenteral

    Posicionamiento de la sonda enteral : concordancia entre el teste de ausculta y rayo-x

    Get PDF
    Objetivo: Avaliar a concordância entre o teste de ausculta e o raio-X na detecção do posicionamento da sonda enteral. Métodos: Estudo transversal realizado em um Centro de Terapia Intensiva do sul do Brasil, em 2011. Enfermeira assistencial e enfermeira pesquisadora realizaram teste de ausculta registrando suas impressões quanto ao posicionamento da sonda enteral em 80 pacientes. Uma médica avaliou o raio-X. Coefi ciente Kappa e PABAK avaliaram as concordâncias. Resultados: O raio-X mostrou 70% das sondas enterais no estômago, 27,4% no duodeno, 1,3% no esôfago e 1,3% no pulmão direito. Houve fraca concordância entre enfermeira assistencial e enfermeira pesquisadora (PABAK =0,054; P=0,103), enfermeira assistencial e raio-X (PABAK=0,188; P=0,111) e enfermeira pesquisadora e raio-X (PABAK =0,128; P=0,107). O teste de ausculta não detectou duas condições de risco, sonda enteral no esôfago e no brônquio. Conclusão: O teste de ausculta mostrou-se pouco concordante com o raio-X na localização da sonda enteral.Objective: to evaluate the correlation between the auscultation test and X-ray when detecting the position of an enteral feeding tube. Methods: cross-sectional study in an intensive care unit in southern Brazil, in 2011. Clinical nurse and nurse researcher performed auscultation test recording the impressions regarding the placement of an enteral feeding tube in 80 patients. A doctor evaluated the X-ray. Kappa coeffi cient and PABAK reviewed the agreements. Results: The X-ray showed that 70% of the enteral tubes were in the stomach, 27.4% in the duodenum, 1.3% in the esophagus, and 1.3% in the right lung. There was a weak correlation between clinical nurses and nurse researchers (PABAK = 0.054; P = 0.103), clinical nurses and X-rays (PABAK = 0.188; P = 0.111) and nurse researchers and X-rays (PABAK = 0.128; P = 0.107) . The auscultation test did not detect two risk conditions, enteral feeding tube in the esophagus and the bronchus. Conclusion: the auscultation test showed little agreement with the X-ray on the enteral feeding tube location.Objetivo: evaluar la concordancia entre test de ausculta y Rayo-X en la detección del posicionamiento de la sonda enteral. Métodos: estudio transversal en un Centro de Terapia Intensiva del sur de Brasil (2011). Enfermero asistencial y enfermero investigadora realizaron teste de ausculta y registraron sus impresiones en 80 pacientes. Una médica evaluó el Rayo-X. Coefi ciente Kappa y PABAK evaluaron las concordancias. Resultados: Rayo-X mostro 70% de las sondas enterales en el estómago, 27,6% en el duodeno, 1,3% en el esófago y 1,3% en el pulmón derecho. Hubo débil concordancia entre enfermero asistencial y enfermero investigadora (PABAK =0,054; P=0,103), enfermero asistencial y Rayo-X (PABAK=0,188; P=0,111) y enfermero investigador y Rayo-X (PABAK =0,128; P=0,107). El teste de ausculta no ha detectado dos condiciones de riesgo, sonda enteral en el esófago y en el bronquio. Conclusión: teste de ausculta se ha mostrado poco concordante con el Rayo-X en la posición de la sonda enteral

    Sondagem enteral: concordância entre teste de ausculta e raio-x na determinação do posicionamento da sonda

    Get PDF
    Objetivo: Avaliar a concordância entre o teste de ausculta e o raio-X na detecção do posicionamento da sonda enteral.Métodos: Estudo transversal realizado em um Centro de Terapia Intensiva do sul do Brasil, em 2011. Enfermeira assistencial e enfermeira pesquisadora realizaram teste de ausculta registrando suas impressões quanto ao posicionamento da sonda enteral em 80 pacientes. Uma médica avaliou o raio-X. Coeficiente Kappa e PABAK avaliaram as concordâncias.Resultados: O raio-X mostrou 70% das sondas enterais no estômago, 27,4% no duodeno, 1,3% no esôfago e 1,3% no pulmão direito. Houve fraca concordância entre enfermeira assistencial e enfermeira pesquisadora (PABAK =0,054; P=0,103), enfermeira assistencial e raio-X (PABAK=0,188; P=0,111) e enfermeira pesquisadora e raio-X (PABAK =0,128; P=0,107). O teste de ausculta não detectou duas condições de risco, sonda enteral no esôfago e no brônquio.Conclusão: O teste de ausculta mostrou-se pouco concordante com o raio-X na localização da sonda enteral.Palavras-chave: Auscultação. Intubação gastrointestinal. Enfermagem
    corecore