437 research outputs found

    Digital Laser Speckle Image Correlation

    Get PDF
    This thesis examines the feasibility of combining Digital Image Correlation (DIC) with laser speckle based methods to form a new hybrid deformation measurement method called Digital Laser Speckle Image Correlation (DilSIC). Consequently, this method does not require any sample preparation and allows for the measurement of displacement of micro structures in addition to large displacements. In this technique, a coherent 30mW-632nm laser beam is expanded with 40X lens and then illuminated on the target surface to produce a fine, homogenous laser speckle pattern. Images were captured before and after deformation due to external load and the whole field displacement and strain were determined by the DIC method. This technique could measure displacement less than 30-ÎĽm with high accuracy when a 120mm Ă— 80mm area of the surface was inspected. Up to 10% strain was measured by this technique with high accuracy during the whole range. Eventually the sub-surface crack was located successfully, which is a revolutionary achievement in NDT optical methods. This method was tested in different material, with different roughness. Aluminum sheet and rubber material were used mostly. This method could broaden the capability of displacement measurement and subsurface crack detection in wide range of materials

    Optimizing the neuroplastic effects of cathodal transcranial direct current stimulation over the primary motor cortex and transferability to prefrontal cortex

    Get PDF
    Die Behandlungsmöglichkeiten neurologischer und neuropsychiatrischer Erkrankungen haben sich in den letzten Jahrzehnten deutlich verbessert, sind aber immer noch eingeschränkt. Eine Dysregulation oder Störung der Neuroplastizität ist bei vielen psychischen und Hirnfunktionsstörungen beteiligt. Hier sind nicht-invasive Hirnstimulationstechniken relevant, die die Plastizität des Gehirns modulieren, ohne die physische Integrität des Schädels zu beeinträchtigen. Eine davon, die transkranielle Gleichstromstimulation (tDCS), hat in mehreren klinischen Pilotstudien vielversprechende Ergebnisse zur Verminderung von Symptomen auf der Grundlage von Störungen des Zentralnervensystems gezeigt. Diese Effekte sind jedoch häufig moderat, zeigen eine nichtlineare Dosisabhängigkeit und eine interindividuelle Variabilität. Um die Wirksamkeit dieses Verfahrens zu verbessern, sind länger anhaltende und homogenere Effekte erforderlich. Dies erfordert neuartige, verbesserte Interventionsstrategien. Darüber hinaus wurden die neuromodulatorischen Wirkungen von tDCS auf den primären motorischen Kortex bisher weitgehend als Grundlage für die Anwendung dieser Intervention auf andere Hirnregionen herangezogen, während eine direkte Untersuchung der physiologischen Wirkungen von tDCS auf nichtmotorische Regionen weitgehend fehlt. Die Arbeit zielt darauf ab, diese Herausforderungen durch den Einsatz innovativer neurophysiologischer und mathematischer Techniken anzugehen, um die Wirksamkeit des kathodalen tDCS über dem primären motorischen Kortex zu verbessern, aber auch die Übertragbarkeit der Ergebnisse auf den präfrontalen Kortex zu untersuchen. Zu diesem Zweck titrierten wir im ersten Schritt systematisch kathodale tDCS-Parameter für das humane motorische Kortexmodell mit unterschiedlichen Intensitäten (1, 2 und 3 mA) und Stimulationsdauern (15, 20 und 30 min). Die Ergebnisse zeigten intensitätsabhängige nichtlineare Effekte, bei denen die Stimulation mit 1 mA eine signifikante Verringerung der Amplitude der motorisch evozierten Potentiale (MEP) induzierte, während die Stimulation mit 2 mA zu einer signifikanten Erhöhung der kortikospinalen Erregbarkeit führte. Protokolle mit höherer Stimulationsintensität (insbesondere Stimulation mit 3 mA) induzierten erneut eine signifikante Verringerung der Erregbarkeit, die etwa eineinhalb Stunden nach der Stimulation andauerte, und waren daher effizienter als die anderen Protokolle. Im zweiten Schritt haben wir untersucht, ob wiederholte tDCS-Protokolle mit unterschiedlichen Intervallen die Nacheffekte verlängern können. Wir verglichen die Auswirkungen von Einzelinterventionen mit konventioneller (1 mA für 15 Minuten) und optimierter kathodaler tDCS (3 mA für 20 Minuten) mit den Auswirkungen einer wiederholten Anwendung in Intervallen von 20 Minuten und 24 Stunden auf die Erregbarkeit des primären motorischen Kortex, basierend auf tierexperimentellen Befunden, dass kurze, aber nicht lange Intervalle zwischen einzelnen Interventionen eine langanhaltende Plastizität erzeugen. Die Ergebnisse zeigten, dass die Dauer der Nacheffekte wiederholter konventioneller und optimierter Protokolle mit kurzen Intervallen im Vergleich zu den jeweiligen Einzelinterventionsprotokollen nahezu unverändert blieb. Für das lange Intervall (24 h) veränderte die Stimulation mit dem herkömmlichen Protokoll die jeweiligen Nachwirkungen nicht signifikant, während sie die Wirksamkeit des optimierten Protokolls im Vergleich zu den jeweiligen Einzelinterventionen verringerte. Ein wichtiges Ergebnis der ersten Studie waren die beobachteten nichtlinearen intensitätsabhängigen Effekte von tDCS, die eine Erklärung für teilweise heterogene Ergebnisse der kathodalen Stimulation bieten können, allerdings hinsichtlich ihrer neurophysiologischen Grundlagen bisher nur unzureichend untersucht waren. Im dritten Schritt haben wir daher die zugrunde liegenden Mechanismen dieser nonlinearen Effekte untersucht. Da tDCS eine NMDA-Rezeptor-abhängige Neuroplastizität erzeugt, die Kalzium-abhängig ist, kann eine solche Nichtlinearität möglicherweise durch unterschiedliche durch die Intervention induzierte Kalziumkonzentrationen erklärt werden, die die Richtung der Plastizität steuern. Wir verabreichten daher den Kalziumkanalblocker Flunarizin in niedrigen (2,5 mg), mittleren (5 mg) oder hohen (10 mg) Dosierungen vor der kathodalen tDCS des motorischen Kortex mit 3 mA für 20 Minuten. Die Ergebnisse zeigten, dass die durch kathodale tDCS hoher Intensität induzierten inhibitorischen Nachwirkungen bei niedrigen, mittleren bzw. hohen Dosierungen eines Kalziumblockers nicht verändert, verringert oder in eine Erregbarkeitserhöhung modifiziert wurden, was die Kalzium-abhängige Direktionalität von tDCS-induzierter Neuroplastizität bestätigt. Das Ergebnis der ersten und zweiten Studie zeigten eine relevante interindividuelle Variabilität der tDCS-Effekte, die eine weitere Quelle für die begrenzte Wirksamkeit dieser Intervention sein könnte. Jüngste In-vivo-Experimente und Computerstudien am Menschen zeigten, dass das tDCS-induzierte elektrische Feld (EF) stark von der individuellen Anatomie des Gehirns und den Leitfähigkeitseigenschaften des Gewebes abhängt. Die EF-Variabilität könnte daher ein wichtiger Faktor für heterogene Ergebnisse der tDCS sein. Im vierten Schritt, basierend auf neurophysiologischen Daten, die in früheren Studien unserer Gruppe erhoben wurden, die tDCS-induzierte MEP- (induziert durch transkranielle Magnetstimulation (TMS)) und zerebrale Blutfluss-Veränderungen (CBF; gemessen durch funktionelle Magnetresonanztomographie (MRT) über arterielles Spin-Labelling) erfaßten, untersuchten wir den Zusammenhang zwischen einzelnen anatomischen Faktoren, tDCS-induziertem EF und den jeweiligen physiologischen Parametern auf der Ebene des Individuums. Zu diesem Zweck wurde für jeden Teilnehmer ein MRT-basiertes realistisches Kopfmodell entworfen, um 1) anatomische Faktoren zu berechnen und 2) die tDCS- und TMS-induzierten elektrischen Felder (EF) zu simulieren. Anschließend untersuchten wir auf regionaler Ebene, welche einzelnen anatomischen Faktoren die simulierten EFs erklären. Schließlich untersuchten wir, welche spezifischen anatomischen und / oder EF-Faktoren die neurophysiologischen Ergebnisse der tDCS vorhersagten. Die Ergebnisse zeigten, dass von den untersuchten anatomischen Faktoren höhere EF-Werte mit einem geringeren Abstand zwischen Elektrode und Kortex (ECD) und einer geringeren Dicke des Liquor cerebrospinalis (CSF) verbunden waren. Zusätzlich waren CSF-Dicke und ECD negativ korreliert, während EFs positiv mit tDCS-induzierten physiologischen Veränderungen korreliert waren. Schließlich untersuchten wir im fünften Schritt die Übertragbarkeit der durch kathodale tDCS induzierten Neuroplastizität vom motorischen auf den präfrontalen Kortex. Die neurophysiologischen Wirkungen von tDCS auf den primärmotorischen Kortex wurden bereits in einer vielzahl von Studien untersucht. Viel weniger ist jedoch hinsichtlich physiologischer Effekte der tDCS auf nichtmotorische Bereiche wie den präfrontalen Kortex bekannt, der eine wichtige Basis für vielfältige kognitive Funktionen darstellt und dessen Dysfunktionen an neuropsychiatrischen Störungen beteiligt sind. Zu diesem Zweck wurde kathodale tDCS mit niedrigen, mittleren und hohen Dosierungen oder eine Placebo-Stimulation über dem primärmotorischen und dorsolateralen präfrontalen Kortex appliziert. Die Nacheffekte der tDCS wurden mittels TMS-Elektroenzephalographie (EEG) und TMS-MEP auf regionaler Ebene für die Ergebnisparameter TMS-evozierte Potentiale (TEP), TMS-evozierte Oszillationen und MEP-Amplitudenänderungen bewertet. Die Ergebnisse zeigten eine dosisabhängige nichtlineare neurophysiologische Wirkung der tDCS über dem motorischen Kortex, die nicht vollständig auf die Ergebnisse der tDCS über dem präfrontalen tDCS übertragbar war. Niedrige und hohe Dosierungen der tDCS über dem motorischen Kortex reduzierten frühe positive TEP-Peaks und MEP-Amplituden, während eine Erhöhung der Amplituden dieser Potentiale für primärmotorische tDCS mit mittlerer Dosierung beobachtet wurde. Im Gegensatz dazu reduzierte präfrontale tDCS mit niedriger, mittlerer und hoher Dosierung die frühen positiven TEP-Amplituden gleichermaßen. Darüber hinaus wurden für beide kortikalen Bereiche keine tDCS-induzierten neuromodulatorischen Effekte auf späte TEP-Amplituden (mit Ausnahme präfrontaler tDCS mit niedriger Dosierung) oder TMS-evozierte Oszillationen beobachtet. Zusammengenommen hat diese Arbeit unter Verwendung innovativer neurophysiologischer, Computergestützter und bildgebender Verfahren wichtige Aspekte in Bezug auf tDCS-induzierte neuroplastische Effekte untersucht, und liefert neue Erkenntnisse für zukünftige Anwendungen von tDCS in Grundlagen- und klinischen Studien.Major advances have been made in treatment of neurological and neuropsychiatric disorders; they have however still significant limitations. A vast body of evidence shows a dysregulation or disruption of neuroplasticity in mental and brain disorders. Here, non-invasive brain stimulation techniques come into play, which modulate brain plasticity without disrupting the integrity of the skull. One of those, transcranial direct current stimulation (tDCS), has shown promising results in several pilot clinical studies to improve symptoms of central nervous system disorders; but, in general, effects are often moderate, show nonlinear dosage-dependency, and interindividual variability. For improving the efficacy of this tool, more sustained, and homogeneous effects are required. This requires novel, improved intervention strategies. In addition, neuromodulatory effects of tDCS over the primary motor cortex were largely taken as a template so far for the use of this intervention over other brain regions, whereas a direct exploration of the physiological effects of tDCS on non-motor regions is largely missing. The thesis aims to address these challenges, by utilizing advanced neurophysiological and computational techniques, aiming to improve the efficacy of cathodal tDCS over the primary motor cortex, but also to explore the transferability of the results to the prefrontal cortex. To this end, we at the first step systematically titrated cathodal tDCS parameters for the human motor cortex model with different intensities (1, 2, and 3mA) and durations (15, 20 and 30 min). The results revealed intensity-dependent nonlinear effects, in which stimulation with 1 mA induced a significant motor evoked potentials (MEP) amplitude diminution, while stimulation with 2 mA resulted in a significant corticospinal excitability enhancement. Protocols with higher stimulation intensity (specifically stimulation with 3 mA) induced again a significant excitability diminution lasting for about one and half hour after stimulation, and thus were more efficient than the other protocols. At the second step, we explored if repeated tDCS protocols with different intervals can prolong the after-effects. We compared the impact of single interventions of conventional (1mA for 15min) and optimized cathodal tDCS (3mA for 20min) with the effects of repeated application with intervals of 20 min and 24 hours on primary motor cortex excitability, based on the assumption derived from animal models that short, but not long intervals induce late phase plasticity. The results revealed that the duration of after-effects of repeated conventional and optimized protocols with short intervals remained nearly unchanged, as compared to the respective single intervention protocols. For the long interval (24 h), stimulation with the conventional protocol did not significantly alter respective after-effects, while it reduced the efficacy of the optimized protocol, as compared with respective single interventions. One important outcome of the first study were the observed nonlinear intensity-dependent effects of tDCS, which might be an explanation for sometimes heterogeneous outcomes of cathodal stimulation, and are not well explained at the neurophysiological level. At the third step we therefore explored the underlaying mechanisms of this nonlinearity. Since tDCS generates NMDA receptor-dependent neuroplasticity, which has calcium channel properties, such non-linearity can likely be explained by different levels of calcium concentration induced by the intervention, which control for the directionality of plasticity. We therefore administrated the calcium channel blocker flunarizine in low (2.5 mg), medium (5 mg) or high (10 mg) dosages before cathodal motor cortex tDCS of 3mA for 20min. The results revealed that the inhibitory after-effects induced by high intensity cathodal tDCS were unchanged, diminished, or converted to excitability enhancement with low, medium and high dosages of a calcium blocker, respectively, which confirms the calcium-dependent directionality of tDCS-induced neuroplasticity. The outcome of the first and second studies showed also relevant inter-individual variability of tDCS effects, which could be another source of limited efficacy of this intervention. Recent human in-vivo experiments and computational studies indicated that the tDCS-induced electrical field (EF) depends strongly on individual brain anatomy and tissue conductivity properties. EF variability might thus be an important factor for heterogeneous outcomes of tDCS. At the fourth step, based on neurophysiological data obtained in former studies of our group, which explored tDCS-altered MEP (induced by transcranial magnetic stimulation (TMS)) and cerebral blood flow (CBF; measured by functional magnetic resonance imaging (MRI) via arterial spin labeling), we investigated the association between individual anatomical factors and tDCS-induced EF, and the respective physiological outcomes at the level of the individual. To this end, for each participant, a MRI-based realistic head model was designed to 1) calculate anatomical factors and 2) simulate the tDCS- and TMS-induced electrical fields (EF). We then investigated at the regional level which individual anatomical factors explain the simulated EFs. Finally, we explored which specific anatomical and/or EF factors predicted the neurophysiological outcomes of tDCS. The results indicated that, of the included anatomical factors, higher EF values were associated with lower electrode to cortex distance (ECD), and cerebrospinal fluid (CSF) thickness. In addition, CSF thickness, and ECD were negatively correlated, whereas EFs were positively correlated with tDCS-induced physiological changes. Finally, at the fifth step, we explored the transferability of cathodal tDCS-induced neuroplasticity from the motor to the prefrontal cortex. Neurophysiological effects of tDCS have been extensively studied over the primary motor cortex. Much less is however known for its effects over non-motor areas, such as the prefrontal cortex, which is the neuronal foundation for many high-level cognitive functions, and involved in neuropsychiatric disorders. To this end, cathodal tDCS was applied with low, medium, and high dosages, or as sham stimulation, and applied over the primary motor and dorsolateral prefrontal cortex. After-effects of tDCS were evaluated via TMS-electroencephalography (EEG), and TMS-MEP at the regional level, for the outcome parameters TMS-evoked potentials (TEP), TMS-evoked oscillations, and MEP amplitude alterations. The results indicated a dosage-dependent nonlinear neurophysiological effect of motor cortex tDCS, which was not one-to-one transferable to the results of prefrontal tDCS. Low and high dosages of motor cortex tDCS reduced early positive TEP peaks, and MEP amplitudes, while an enhancement was observed for medium dosage motor cortex tDCS (early positive TEP peak and MEP amplitudes). In contrast, prefrontal low, medium and high dosage tDCS uniformly reduced the early positive TEP peak amplitudes. Furthermore, for both cortical areas, tDCS-induced neuromodulatory effects were not observed for late TEP peaks (with the exception of low-dosage prefrontal tDCS), nor TMS-evoked oscillations. Taken together, using advanced neurophysiological, computational and neuroimaging techniques, this thesis has addressed important challenges regarding tDCS-induced neuroplastic effects, and thus provides new insight for future applications of tDCS in basic and clinical studies

    Receivers for Diffusion-Based Molecular Communication: Exploiting Memory and Sampling Rate

    Full text link
    In this paper, a diffusion-based molecular communication channel between two nano-machines is considered. The effect of the amount of memory on performance is characterized, and a simple memory-limited decoder is proposed and its performance is shown to be close to that of the best possible imaginable decoder (without any restriction on the computational complexity or its functional form), using Genie-aided upper bounds. This effect is specialized for the case of Molecular Concentration Shift Keying; it is shown that a four-bits memory achieved nearly the same performance as infinite memory. Then a general class of threshold decoders is considered and shown not to be optimal for Poisson channel with memory, unless SNR is higher than a value specified in the paper. Another contribution is to show that receiver sampling at a rate higher than the transmission rate, i.e., a multi-read system, can significantly improve the performance. The associated decision rule for this system is shown to be a weighted sum of the samples during each symbol interval. The performance of the system is analyzed using the saddle point approximation. The best performance gains are achieved for an oversampling factor of three.Comment: Submitted to JSA

    Force-induced rupture of a DNA duplex

    Full text link
    The rupture of double-stranded DNA under stress is a key process in biophysics and nanotechnology. In this article we consider the shear-induced rupture of short DNA duplexes, a system that has been given new importance by recently designed force sensors and nanotechnological devices. We argue that rupture must be understood as an activated process, where the duplex state is metastable and the strands will separate in a finite time that depends on the duplex length and the force applied. Thus, the critical shearing force required to rupture a duplex within a given experiment depends strongly on the time scale of observation. We use simple models of DNA to demonstrate that this approach naturally captures the experimentally observed dependence of the critical force on duplex length for a given observation time. In particular, the critical force is zero for the shortest duplexes, before rising sharply and then plateauing in the long length limit. The prevailing approach, based on identifying when the presence of each additional base pair within the duplex is thermodynamically unfavorable rather than allowing for metastability, does not predict a time-scale-dependent critical force and does not naturally incorporate a critical force of zero for the shortest duplexes. Additionally, motivated by a recently proposed force sensor, we investigate application of stress to a duplex in a mixed mode that interpolates between shearing and unzipping. As with pure shearing, the critical force depends on the time scale of observation; at a fixed time scale and duplex length, the critical force exhibits a sigmoidal dependence on the fraction of the duplex that is subject to shearing.Comment: 10 pages, 6 figure

    The Relationship between Leadership Styles and Spiritual Intelligence of Managers Headquarter units of the Kerman University of Medical Sciences in 2016

    Get PDF
    The Relationship between Leadership Styles and Spiritual Intelligence of Managers Headquarter units of the Kerman University of Medical Sciences in 2016 Nekooee Moghadam Mahmood1, Mosayebi Ardakani Atefeh2*, Amiresmaili Mohammadreza3 Received: 28. 08. 2016 Revised: 31. 08. 2016 Accepted: 13. 09. 2016 Abstract Introduction: One of the managers’ characteristics that lead to the success of the modern organizations is managers’ intelligence. The intelligence that enable managers to make strategic decisions in these organizations is spiritual intelligence. Another characteristic of managers that lead to the success of the organizations is how to apply the effective leadership styles. The aim of this study was to investigate the relationship between leadership styles and managers’ spiritual intelligence in Kerman University of Medical Sciences in 2016. Methods: This descriptive-analytical study was performed on 71 managers of Kerman University of Medical Sciences in the three levels of management who were selected using census method. In this study, spiritual intelligence was measured using King Questionnaire and leadership style was measured using Metzcus & Burdens questionnaire. Data were analyzed using SPSS 16. Then Structural Equation Modeling (SEM) was used by Smart PLS 2.0. Results: The results showed that managers of Kerman University of Medical Sciences often use task-oriented leadership style (67%). There was a significant positive relationship between the spiritual intelligence and leadership styles and also between the spiritual intelligence and education level of managers (P=0.01). It was also revealed that the managers who use the combination of leadership style, have higher level of spiritual intelligence. Conclusion: Due to the condition of modern organizations which are always faced with different challenges, managers are recommended to raise the level of their spiritual intelligence by reinforcing their beliefs and values and using the combination of leadership style for leading the organization. Key¬words: Spiritual Intelligence, Leadership Style, Operational Managers, Middle Managers, Master Managers ¬Citation: Nekooee Moghadam M, Amiresmaelee MR, Mosayebi Ardakani A. The Relationship between Leadership Styles and Spiritual Intelligence of Managers Headquarter units of the Kerman University of Medical Sciences in 2016. Journal of Health Based Research 2016; 2(2): 173-182. 1. Professor, Health Services Management Research Center, Institute for Futures Studies in Health, Kerman University of Medical Sciences, Kerman, Iran. 2. MSc, School of Management & Medical Information Science, Kerman University of Medical Siences, Kerman, Iran. 3. Associate Professor, Research Center for Modeling in Health, Institute for Futures Studies in Health, Kerman University of Medical Sciences, Kerman, Iran. *Correspondence: Campus of Kerman University of Medical Sciences.Haft Baghe Alavi. Tel: 083532247808 Email: [email protected]
    • …
    corecore