17 research outputs found

    A novel method for engineering autologous non-thrombogenic in situ tissue-engineered blood vessels for arteriovenous grafting

    Get PDF
    The durability of prosthetic arteriovenous (AV) grafts for hemodialysis access is low, predominantly due to stenotic lesions in the venous outflow tract and infectious complications. Tissue engineered blood vessels (TEBVs) might offer a tailor-made autologous alternative for prosthetic grafts. We have designed a method in which TEBVs are grown in vivo, by utilizing the foreign body response to subcutaneously implanted polymeric rods in goats, resulting in the formation of an autologous fibrocellular tissue capsule (TC). One month after implantation, the polymeric rod is extracted, whereupon TCs (length 6 cm, diameter 6.8 mm) were grafted as arteriovenous conduit between the carotid artery and jugular vein of the same goats. At time of grafting, the TCs were shown to have sufficient mechanical strength in terms of bursting pressure (2382 +/- 129 mmHg), and suture retention strength (SRS: 1.97 +/- 0.49 N). The AV grafts were harvested at 1 or 2 months after grafting. In an ex vivo whole blood perfusion system, the lumen of the vascular grafts was shown to be less thrombogenic compared to the initial TCs and ePTFE grafts. At 8 weeks after grafting, the entire graft was covered with an endothelial layer and abundant elastin expression was present throughout the graft. Patency at 1 and 2 months was comparable with ePTFE AV-grafts. In conclusion, we demonstrate the remodeling capacity of cellularized in vivo engineered TEBVs, and their potential as autologous alternative for prosthetic vascular grafts.Vascular Surger

    Large-scale association analysis provides insights into the genetic architecture and pathophysiology of type 2 diabetes

    Get PDF
    To extend understanding of the genetic architecture and molecular basis of type 2 diabetes (T2D), we conducted a meta-analysis of genetic variants on the Metabochip involving 34,840 cases and 114,981 controls, overwhelmingly of European descent. We identified ten previously unreported T2D susceptibility loci, including two demonstrating sex-differentiated association. Genome-wide analyses of these data are consistent with a long tail of further common variant loci explaining much of the variation in susceptibility to T2D. Exploration of the enlarged set of susceptibility loci implicates several processes, including CREBBP-related transcription, adipocytokine signalling and cell cycle regulation, in diabetes pathogenesis

    A novel method for engineering autologous non-thrombogenic in situ tissue-engineered blood vessels for arteriovenous grafting

    No full text
    The durability of prosthetic arteriovenous (AV) grafts for hemodialysis access is low, predominantly due to stenotic lesions in the venous outflow tract and infectious complications. Tissue engineered blood vessels (TEBVs) might offer a tailor-made autologous alternative for prosthetic grafts. We have designed a method in which TEBVs are grown in vivo, by utilizing the foreign body response to subcutaneously implanted polymeric rods in goats, resulting in the formation of an autologous fibrocellular tissue capsule (TC). One month after implantation, the polymeric rod is extracted, whereupon TCs (length 6 cm, diameter 6.8 mm) were grafted as arteriovenous conduit between the carotid artery and jugular vein of the same goats. At time of grafting, the TCs were shown to have sufficient mechanical strength in terms of bursting pressure (2382 ± 129 mmHg), and suture retention strength (SRS: 1.97 ± 0.49 N). The AV grafts were harvested at 1 or 2 months after grafting. In an ex vivo whole blood perfusion system, the lumen of the vascular grafts was shown to be less thrombogenic compared to the initial TCs and ePTFE grafts. At 8 weeks after grafting, the entire graft was covered with an endothelial layer and abundant elastin expression was present throughout the graft. Patency at 1 and 2 months was comparable with ePTFE AV-grafts. In conclusion, we demonstrate the remodeling capacity of cellularized in vivo engineered TEBVs, and their potential as autologous alternative for prosthetic vascular grafts.Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Fluid MechanicsMulti Phase System

    Homozygous DNA ligase IV R278H mutation in mice leads to leaky SCID and represents a model for human LIG4 syndrome

    No full text
    DNA ligase IV (LIG4) is an essential component of the nonhomologous end-joining (NHEJ) repair pathway and plays a key role in V(D)J recombination. Hypomorphic LIG4 mutations in humans are associated with increased cellular radiosensitivity, microcephaly, facial dysmorphisms, growth retardation, developmental delay, and a variable degree of immunodeficiency. We have generated a knock-in mouse model with a homozygous Lig4 R278H mutation that corresponds to the first LIG4 mutation reported in humans. The phenotype of homozygous mutant mice Lig4R278H/R278H (Lig4R/R) includes growth retardation, a decreased life span, a severe cellular sensitivity to ionizing radiation, and a very severe, but incomplete block in T and B cell development. Peripheral T lymphocytes show an activated and anergic phenotype, reduced viability, and a restricted repertoire, reminiscent of human leaky SCID. Genomic instability is associated with a high rate of thymic tumor development. Finally, Lig4R/R mice spontaneously produce low-affinity antibodies that include autoreactive specificities, but are unable to mount high-affinity antibody responses. These findings highlight the importance of LIG4 in lymphocyte development and function, and in genomic stability maintenance, and provide a model for the complex phenotype of LIG4 syndrome in humans
    corecore