278 research outputs found

    Isolation and Monitoring of the Endohedral Metallofullerenes Y@C82 and Sc3@C82:On-Line Chromatographic Separation with EPR Detection

    Get PDF
    The direct coupling of high-performance liquid chromatography (HPLC) with on-line electron paramagnetic resonance (EPR) detection is demonstrated for monitoring separations of endohedral metallofullerenes (M@C2n). The HPLC-EPR approach readily permits detection of the paramagnetic species, such as Y@C82 and Sc3@C82, in the presence of the dominant empty-cage fullerenes (C60, C70) and diamagnetic metallofullerenes (e.g., M2@C2n). The results indicate that on-line EPR provides a noninvasive, selective detector for HPLC metallofullerene separations that is readily adaptable to air-sensitive and/or labile compounds. Specifically, the “EPR-active” metallofullerenes, Y@C82 and Sc3@C82, are selectively monitored on-line for an initial separation of the metallofullerene fraction from the dominant empty-cage fullerenes utilizing a combination of polystyrene columns. This preparative “cleanup” procedure is followed by HPLC-EPR separation and monitoring of Y@C82 and Sc3@C82 species using a selective tripodal π-acidic-phase column (Trident-Tri-DNP) for the final stages of isolation

    Torque teno virus loads after kidney transplantation predict allograft rejection but not viral infection

    Get PDF
    The main challenge of immunosuppressive therapy after solid organ transplantation is to create a new immunological balance that prevents organ rejection and does not promote opportunistic infection. Torque teno virus (TTV), a ubiquitous and non-pathogenic single-stranded DNA virus, has been proposed as a marker of functional immunity in immunocompromised patients. Here we investigate whether TTV loads predict the risk of common viral infection and allograft rejection in kidney transplantation recipients.In a retrospective cohort of 389 kidney transplantation recipients, individual TTV loads in were measured by qPCR in consecutive plasma samples during one year follow-up. The endpoints were allograft rejection, BK polyomavirus (BKPyV) viremia and cytomegalovirus (CMV) viremia. Repeated TTV measurements and rejection and infection survival data were analysed in a joint model.During follow-up, TTV DNA detection in the transplant recipients increased from 85 to 100%. The median viral load increased to 107 genome copies/ml within three months after transplantation. Rejection, BKPyV viremia and CMV viremia occurred in 23%, 27% and 17% of the patients, respectively. With every 10-fold TTV load-increase, the risk of rejection decreased considerably (HR: 0.74, CI 95%: 0.71-0.76), while the risk of BKPyV and CMV viremia remained the same (HR: 1.03, CI 95%: 1.03-1.04 and HR: 1.01, CI 95%: 1.01-1.01).In conclusion, TTV load kinetics predict allograft rejection in kidney transplantation recipients, but not the BKPyV and CMV infection. The potential use of TTV load levels as a guide for optimal immunosuppressive drug dosage to prevent allograft rejection deserves further validation.Development and application of statistical models for medical scientific researc

    Prompt atmospheric neutrino fluxes: perturbative QCD models and nuclear effects

    Full text link
    We evaluate the prompt atmospheric neutrino flux at high energies using three different frameworks for calculating the heavy quark production cross section in QCD: NLO perturbative QCD, kTk_T factorization including low-xx resummation, and the dipole model including parton saturation. We use QCD parameters, the value for the charm quark mass and the range for the factorization and renormalization scales that provide the best description of the total charm cross section measured at fixed target experiments, at RHIC and at LHC. Using these parameters we calculate differential cross sections for charm and bottom production and compare with the latest data on forward charm meson production from LHCb at 77 TeV and at 1313 TeV, finding good agreement with the data. In addition, we investigate the role of nuclear shadowing by including nuclear parton distribution functions (PDF) for the target air nucleus using two different nuclear PDF schemes. Depending on the scheme used, we find the reduction of the flux due to nuclear effects varies from 10%10\% to 50%50 \% at the highest energies. Finally, we compare our results with the IceCube limit on the prompt neutrino flux, which is already providing valuable information about some of the QCD models.Comment: 61 pages, 25 figures, 11 table

    Reducing medical device alarms by an order of magnitude: A human factors approach

    Get PDF
    The intensive care unit (ICU) is one of the most technically advanced environments in healthcare, using a multitude of medical devices for drug administration, mechanical ventilation and patient monitoring. However, these technologies currently come with disadvantages, namely noise pollution, information overload and alarm fatigue—all caused by too many alarms. Individual medical devices currently generate alarms independently, without any coordination or prioritisation with other devices, leading to a cacophony where important alarms can be lost amongst trivial ones, occasionally with serious or even fatal consequences for patients. We have called this approach to the design of medical devices the single-device paradigm, and believe it is obsolete in modern hospitals where patients are typically connected to several devices simultaneously. Alarm rates of one alarm every four minutes for only the physiological monitors (as recorded in the ICUs of two hospitals contributing to this paper) degrades the quality of the patient’s healing environment and threatens patient safety by constantly distracting healthcare professionals. We outline a new approach to medical device design involving the application of human factors principles which have been successful in eliminating alarm fatigue in commercial aviation. Our approach comprises the networked-device paradigm, comprehensive alarms and humaniform information displays. Instead of each medical device alarming separately at the patient’s bedside, our proposed approach will integrate, prioritise and optimise alarms across all devices attached to each patient, display information more intuitively and hence increase alarm quality while reducing the number of alarms by an order of magnitude below current levels

    Probing exotic phenomena at the interface of nuclear and particle physics with the electric dipole moments of diamagnetic atoms: A unique window to hadronic and semi-leptonic CP violation

    Full text link
    The current status of electric dipole moments of diamagnetic atoms which involves the synergy between atomic experiments and three different theoretical areas -- particle, nuclear and atomic is reviewed. Various models of particle physics that predict CP violation, which is necessary for the existence of such electric dipole moments, are presented. These include the standard model of particle physics and various extensions of it. Effective hadron level combined charge conjugation (C) and parity (P) symmetry violating interactions are derived taking into consideration different ways in which a nucleon interacts with other nucleons as well as with electrons. Nuclear structure calculations of the CP-odd nuclear Schiff moment are discussed using the shell model and other theoretical approaches. Results of the calculations of atomic electric dipole moments due to the interaction of the nuclear Schiff moment with the electrons and the P and time-reversal (T) symmetry violating tensor-pseudotensor electron-nucleus are elucidated using different relativistic many-body theories. The principles of the measurement of the electric dipole moments of diamagnetic atoms are outlined. Upper limits for the nuclear Schiff moment and tensor-pseudotensor coupling constant are obtained combining the results of atomic experiments and relativistic many-body theories. The coefficients for the different sources of CP violation have been estimated at the elementary particle level for all the diamagnetic atoms of current experimental interest and their implications for physics beyond the standard model is discussed. Possible improvements of the current results of the measurements as well as quantum chromodynamics, nuclear and atomic calculations are suggested.Comment: 46 pages, 19 tables and 16 figures. A review article accepted for EPJ

    Prophylactic Medication for the Prevention of Endoscopic Recurrence in Crohn's Disease: a Prospective Study Based on Clinical Risk Stratification

    Get PDF
    Background To prevent recurrence after ileocolonic resection [ICR] in Crohn's disease [CD], postoperative prophylaxis based on risk stratification is recommended in international guidelines. This study aimed to evaluate postoperative CD recurrence after implementation of a clinical management algorithm and to determine the predictive value of clinical and histological risk factors [RFs]. Methods In this multicentre, prospective cohort study, CD patients [>= 16 years] scheduled for ICR were included. The algorithm advised no postoperative medication for low-risk patients, and treatment with prophylaxis [immunosuppressant/biological] for high-risk patients [>= 1 RF: active smoking, penetrating disease, prior ICR]. Clinical and histological RFs [active inflammation, granulomas, plexitis in resection margins] for endoscopic recurrence [Rutgeerts' score >= i2b at 6 months] were assessed using logistic regression and ROC curves based on predicted probabilities. Results In total, 213 CD patients after ICR were included [age 34.5 years; 65% women] (93 [44%] low-risk; 120 [56%] high-risk: 45 [38%] smoking; 51 [43%] penetrating disease; 51 [43%] prior ICR). Adherence to the algorithm was 82% in low-risk [no prophylaxis] and 51% in high-risk patients [prophylaxis]. Endoscopic recurrence was higher in patients treated without prophylaxis than with prophylaxis in both low [45% vs 16%, p = 0.012] and high-risk patients [49% vs 26%, p = 0.019]. Clinical risk stratification including the prescription of prophylaxis corresponded to an area under the curve [AUC] of 0.70 (95% confidence interval [CI] 0.61-0.79). Clinical RFs combined with histological RFs increased the AUC to 0.73 [95% CI 0.64-0.81]. Conclusion Adherence to this management algorithm is 65%. Prophylactic medication after ICR prevents endoscopic recurrence in low- and high-risk patients. Clinical risk stratification has an acceptable predictive value, but further refinement is needed.Cellular mechanisms in basic and clinical gastroenterology and hepatolog

    Design and construction of the MicroBooNE detector

    Get PDF
    This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, and acceptance tests are reported
    corecore