196 research outputs found

    The 2011 February superoutburst of the dwarf nova SDSS J112003.40+663632.4

    Get PDF
    We report unfiltered photometry of SDSS J112003.40+663632.4 during the 2011 February outburst which revealed the presence of superhumps with peak-to-peak amplitude of up to 0.22 magnitudes showing this to be an SU UMa type dwarf nova. The outburst amplitude was 5.4 magnitudes above mean quiescence and it lasted at least 12 days. The mean superhump period during the plateau phase was Psh = 0.07057(19) d.Comment: Accepted for publication in the Journal of the British Astronomical Association. 12 pages, 5 figure

    Role of Imaging in Left Atrial Appendage Occlusion

    Get PDF
    Percutaneous left atrial appendage (LAA) occlusion is now a valid alternative to long-term oral anticoagulation in patients with non-valvular atrial fibrillation at high thrombo-embolism risk, especially for patients who are considered ineligible for anticoagulation. The most frequently used occluders worldwide include the WATCHAMN (Boston Scientific, Natick, MA, USA) and the Amplatzer Cardiac Plug or Amulet (St. Jude Medical/Abbott, St Paul, MN, USA) devices. Multimodality imaging is key in the understanding of 3D aspects of the LAA and surrounding structures anatomy. Imaging is essential for procedural planning, during each step of the procedure and for device surveillance after implantation. Multimodality imaging, including 2D/3D echocardiography, fluoroscopy, and cardiac computed tomography can increase the safety and efficacy of the procedure

    Efficacy and safety of left atrial appendage closure with WATCHMAN in patients with or without contraindication to oral anticoagulation: 1-Year follow-up outcome data of the EWOLUTION trial

    Get PDF
    Background Left atrial appendage (LAA) occlusion with WATCHMAN has emerged as viable alternative to vitamin K antagonists in randomized controlled trials. Objective EWOLUTION was designed to provide data in routine practice from a prospective multicenter registry. Methods A total of 1025 patients scheduled for a WATCHMAN implant were prospectively and sequentially enrolled at 47 centers. Indication for LAA closure was based on European Society of Cardiology guidelines. Follow-up and transesophageal echocardiography (TEE) were performed per local practice. Results The baseline CHA 2 DS 2 -VASc score was 4.5 ± 1.6; the mean age was 73.4 ± 9 years; previous transient ischemic attack/ischemic stroke was present in 312 (30.5%), 155 (15.1%) had previous hemorrhagic stroke, and 320 (31.3%) had a history of major bleeding; and 750 (73%) were deemed unsuitable for oral anticoagulation therapy. WATCHMAN implant succeeded in 1005 (98.5%) of patients, without leaks >5 mm in 1002 (99.7%) with at least 1 TEE follow-up in 875 patients (87%). Antiplatelet therapy was used in 784 (83%), while vitamin K antagonists were used in only 75 (8%). At 1 year, mortality was 98 (9.8%), reflecting the advanced age and comorbidities in this population. Device thrombus was observed in 28 patients at routine TEE (3.7%) and was not correlated with the drug regimen ( P = .14). Ischemic stroke rate was 1.1% (relative risk 84% vs estimated historical data); the major bleeding rate was 2.6% and was predominantly (2.3%) nonprocedure/device related. Conclusion LAA closure with the WATCHMAN device has a high implant and sealing success. This method of stroke risk reduction appears to be safe and effective with an ischemic stroke rate as low as 1.1%, even though 73% of patients had a contraindication to and were not using oral anticoagulation

    Catheter Ablation of Atrial Fibrillation in Patients with Previous Lobectomy or Partial Lung Resection: Long-Term Results of an International Multicenter Study.

    Get PDF
    INTRODUCTION Data regarding the efficacy of catheter ablation in patients with atrial fibrillation (AF) and patients' previous history of pulmonary lobectomy/pneumonectomy are scanty. We sought to evaluate the efficacy and long-term follow-up of catheter ablation in this highly selected group of patients. MATERIAL AND METHODS Twenty consecutive patients (8 females, 40%; median age 65.2 years old) with a history of pneumonectomy/lobectomy and paroxysmal or persistent AF, treated by means of pulmonary vein isolation (PVI) at ten participating centers were included. Procedural success, intra-procedural complications, and AF recurrences were considered. RESULTS Fifteen patients had a previous lobectomy and five patients had a complete pneumonectomy. A large proportion (65%) of PV stumps were electrically active and represented a source of firing in 20% of cases. PVI was performed by radiofrequency ablation in 13 patients (65%) and by cryoablation in the remaining 7 cases. Over a median follow up of 29.7 months, a total of 7 (33%) AF recurrences were recorded with neither a difference between patients treated with cryoablation or radiofrequency ablation or between the two genders. CONCLUSIONS Catheter ablation by radiofrequency ablation or cryoablation in patients with pulmonary stumps is feasible and safe. Long-term outcomes are favorable, and a similar efficacy of catheter ablation has been noticed in both males and females

    Changes in quality of life, cognition and functional status following catheter ablation of atrial fibrillation

    Get PDF
    Objective To investigate changes in quality of life (QoL), cognition and functional status according to arrhythmia recurrence after atrial fibrillation (AF) ablation. Methods We compared QoL, cognition and functional status in patients with recurrent atrial tachycardia (AT)/AF versus those without recurrent AT/AF in the AXAFA-AFNET 5 clinical trial. We also sought to identify factors associated with improvement in QoL and functional status following AF ablation by overall change scores with and without analysis of covariance (ANCOVA). Results Among 518 patients who underwent AF ablation, 154 (29.7%) experienced recurrent AT/AF at 3 months. Patients with recurrent AT/AF had higher mean CHA(2)DS(2)-VASc scores (2.8 vs 2.3, p Conclusions Patients without recurrent AT/AF appear to experience greater improvement in functional status but similar QoL as those with recurrent AT/AF after AF ablation

    Troponin T in COVID-19 hospitalized patients: Kinetics matter

    Get PDF
    Background: Coronavirus disease 2019 (COVID-19) emerged as a worldwide health crisis, overwhelming healthcare systems. Elevated cardiac troponin T (cTn T) at admission was associated with increased in-hospital mortality. However, data addressing the role of cTn T in major adverse cardiovascular events (MACE) in COVID-19 are scarce. Therefore, we assessed the role of baseline cTn T and cTn T kinetics for MACE and in-hospital mortality prediction in COVID-19.Methods: Three hundred and ten patients were included prospectively. One hundred and eight patients were excluded due to incomplete records. Patients were divided into three groups according to cTn T kinetics: ascending, descending, and constant. The cTn T slope was defined as the ratio of the cTn T change over time. The primary and secondary endpoints were MACE and in-hospital mortality.Results: Two hundred and two patients were included in the analysis (mean age 64.4 ± 16.7 years, 119 [58.9%] males). Mean duration of hospitalization was 14.0 ± 12.3 days. Sixty (29.7%) patients had MACE, and 40 (19.8%) patients died. Baseline cTn T predicted both endpoints (p = 0.047, hazard ratio [HR] 1.805, 95% confidence interval [CI] 1.009–3.231; p = 0.009, HR 2.322, 95% CI 1.234–4.369). Increased cTn T slope predicted mortality (p = 0.041, HR 1.006, 95% CI 1.000–1.011). Constant cTn T was associated with lower MACE and mortality (p = 0.000, HR 3.080, 95% CI 1.914–4.954, p = 0.000, HR 2.851, 95% CI 1.828–4.447).Conclusions: The present study emphasizes the additional role of cTn T testing in COVID-19 patients for risk stratification and improved diagnostic pathway and management
    • …
    corecore