688 research outputs found

    The Low Quiescent X-Ray Luminosity of the Transient X-Ray Burster EXO 1747-214

    Full text link
    We report on X-ray and optical observations of the X-ray burster EXO 1747-214. This source is an X-ray transient, and its only known outburst was observed in 1984-1985 by the EXOSAT satellite. We re-analyzed the EXOSAT data to derive the source position, column density, and a distance upper limit using its peak X-ray burst flux. We observed the EXO 1747-214 field in 2003 July with the Chandra X-ray Observatory to search for the quiescent counterpart. We found one possible candidate just outside the EXOSAT error circle, but we cannot rule out the possibility that the source is unrelated to EXO 1747-214. Our conclusion is that the upper limit on the unabsorbed 0.3-8 keV luminosity is L < 7E31 erg/s, making EXO 1747-214 one of the faintest neutron star transients in quiescence. We compare this luminosity upper limit to the quiescent luminosities of 19 neutron star and 14 black hole systems and discuss the results in the context of the differences between neutron stars and black holes. Based on the theory of deep crustal heating by Brown and coworkers, the luminosity implies an outburst recurrence time of >1300 yr unless some form of enhanced cooling occurs within the neutron star. The position of the possible X-ray counterpart is consistent with three blended optical/IR sources with R-magnitudes between 19.4 and 19.8 and J-magnitudes between 17.2 and 17.6. One of these sources could be the quiescent optical/IR counterpart of EXO 1747-214.Comment: 7 pages, accepted by the Astrophysical Journa

    Teleworking practice in small and medium-sized firms: Management style and worker autonomy

    Get PDF
    In an empirical study of teleworking practices amongst small and medium-sized enterprises (SMEs) in West London, organisational factors such as management attitudes, worker autonomy and employment flexibility were found to be more critical than technological provision in facilitating successful implementation. Consequently, we argue that telework in most SMEs appears as a marginal activity performed mainly by managers and specialist mobile workers

    Direct response of twin-slot antenna-coupled hot-electron bolometer mixers designed for 2.5 THz radiation detection

    Get PDF
    We measure the direct response of a Nb diffusion-cooled hot-electron bolometer mixer in a frequency range between 0.5 and 3.5 THz. The mixer consists essentially of a twin-slot antenna, a co-planar waveguide transmission line and a Nb superconducting bridge. It is designed for use in receivers with astronomical and atmospherical applications around 2.5 THz. We calculate the impedance of the antenna, the transmission line, and the bridge separately using models which are developed for frequencies below 1 THz and predict the direct response of the mixer. We demonstrate that these models can be applied to much higher frequencies. However, the measured central frequency is 10%-15% lower than predicted. (C) 2000 American Institute of Physics. [S0003-6951(00)02022-2]

    Opportunities for mesoscopics in thermometry and refrigeration: Physics and applications

    Get PDF
    This review presents an overview of the thermal properties of mesoscopic structures. The discussion is based on the concept of electron energy distribution, and, in particular, on controlling and probing it. The temperature of an electron gas is determined by this distribution: refrigeration is equivalent to narrowing it, and thermometry is probing its convolution with a function characterizing the measuring device. Temperature exists, strictly speaking, only in quasiequilibrium in which the distribution follows the Fermi-Dirac form. Interesting nonequilibrium deviations can occur due to slow relaxation rates of the electrons, e.g., among themselves or with lattice phonons. Observation and applications of nonequilibrium phenomena are also discussed. The focus in this paper is at low temperatures, primarily below 4 K, where physical phenomena on mesoscopic scales and hybrid combinations of various types of materials, e.g., superconductors, normal metals, insulators, and doped semiconductors, open up a rich variety of device concepts. This review starts with an introduction to theoretical concepts and experimental results on thermal properties of mesoscopic structures. Then thermometry and refrigeration are examined with an emphasis on experiments. An immediate application of solid-state refrigeration and thermometry is in ultrasensitive radiation detection, which is discussed in depth. This review concludes with a summary of pertinent fabrication methods of presented devices.Comment: Close to the version published in RMP; 59 pages, 35 figure

    Driving pressure during general anesthesia for open abdominal surgery (DESIGNATION) : study protocol of a randomized clinical trial

    Get PDF
    Background Intraoperative driving pressure (Delta P) is associated with development of postoperative pulmonary complications (PPC). When tidal volume (V-T) is kept constant, Delta P may change according to positive end-expiratory pressure (PEEP)-induced changes in lung aeration. Delta P may decrease if PEEP leads to a recruitment of collapsed lung tissue but will increase if PEEP mainly causes pulmonary overdistension. This study tests the hypothesis that individualized high PEEP, when compared to fixed low PEEP, protects against PPC in patients undergoing open abdominal surgery. Methods The "Driving prESsure durIng GeNeral AnesThesIa for Open abdomiNal surgery trial" (DESIGNATION) is an international, multicenter, two-group, double-blind randomized clinical superiority trial. A total of 1468 patients will be randomly assigned to one of the two intraoperative ventilation strategies. Investigators screen patients aged >= 18 years and with a body mass index <= 40 kg/m(2), scheduled for open abdominal surgery and at risk for PPC. Patients either receive an intraoperative ventilation strategy with individualized high PEEP with recruitment maneuvers (RM) ("individualized high PEEP") or one in which PEEP of 5 cm H2O without RM is used ("low PEEP"). In the "individualized high PEEP" group, PEEP is set at the level at which Delta P is lowest. In both groups of the trial, V-T is kept at 8 mL/kg predicted body weight. The primary endpoint is the occurrence of PPC, recorded as a collapsed composite of adverse pulmonary events. Discussion DESIGNATION will be the first randomized clinical trial that is adequately powered to compare the effects of individualized high PEEP with RM versus fixed low PEEP without RM on the occurrence of PPC after open abdominal surgery. The results of DESIGNATION will support anesthesiologists in their decisions regarding PEEP settings during open abdominal surgery
    • 

    corecore