149 research outputs found

    Introduction. Carotid endarterectomy versus carotid stenting. A never-ending story

    Get PDF
    L'articolo discute le controversie relative all'accettazione in pratica clinica dello stentig carotide

    Long-term results of carotid artery stenting

    Get PDF
    ObjectiveData regarding the long-term efficacy of carotid artery stenting (CAS) are still scarce. As demonstrated by several major randomized controlled trials (RCT) comparing the efficacy of carotid endarterectomy (CEA) vs medical therapy, even after successful carotid revascularization late ipsilateral stroke occurs in 5-13% at 5 years. Therefore, major concerns also remain about the durability of the CAS procedure in terms of stroke prevention. The purpose of this study was to review long-term results after carotid stent implantation in a large cohort of patients.MethodsThis retrospective investigation involved 3179 CAS procedures performed at four European carotid high-volume centers. Echo-duplex scan using modified velocity criteria to recognize in-stent restenosis (ISR) and neurological examinations of all patients were carried out every 6 months after the procedure. Life-table analysis was used to determine freedom from mortality, stroke-related death, ipsilateral fatal/major stroke, and any ipsilateral stroke. Freedom from ISR and from reintervention were also reported. The secondary aim was to identify predictive risk factors for neurological complications and ISR.ResultsAt 5 years freedom from mortality, stroke-related death, ipsilateral fatal/major stroke, and any stroke rate were 82%, 93.5%, 93.3%, and 91.9%, respectively. The only predictor for neurological complications was the presence of neurological symptoms before CAS (hazard ratio 1.38 [CI 1.05, 1.82] P = .02). Freedom from restenosis at 1, 3, and 5 years was, respectively, 98.4%, 96.1%, and 94%. Uni- and multi-variate analyses showed that stent characteristics (material/design/free-cell area) were not significantly associated with time to in-stent restenosis or time to reintervention.ConclusionOur long-term results in a large cohort of patients validated CAS as a durable procedure for stroke prevention. The annual rate of neurological complications after CAS was comparable to that of conventional surgery as demonstrated by large RCTs involving both symptomatic patients (North American Symptomatic Carotid Endarterectomy Trial [NASCET] and European Carotid Surgery Trial [ECST]) and asymptomatic patients (Asymptomatic Carotid Atherosclerosis Study [ACAS] and Asymptomatic Carotid Surgery Trial [ACST])

    Endovascular Abdominal Aortic Aneurysm Repair With Ovation Alto Stent Graft: Protocol for the ALTAIR (ALTo endogrAft Italian Registry) Study

    Get PDF
    Background: Since 2010, the Ovation Abdominal Stent Graft System has offered an innovative sealing option for abdominal aortic aneurysm (AAA) by including a sealing ring filled with polymer 13 mm from the renal arteries. In August 2020, the redesigned Ovation Alto, with a sealing ring 6 mm closer to the top of the fabric, received CE Mark approval. Objective: This registry study aims to evaluate intraoperative, perioperative, and postoperative results in patients treated by the Alto stent graft (Endologix Inc.) for elective AAA repair in a multicentric consecutive experience. Methods: All consecutive eligible patients submitted to endovascular aneurysm repair (EVAR) by Alto Endovascular AAA implantation will be included in this analysis. Patients will be submitted to EVAR procedures based on their own preferences, anatomical features, and operators experience. An estimated number of 300 patients submitted to EVAR with Alto stent graft should be enrolled. It is estimated that the inclusion period will be 24 months. The follow-up period is set to be 5 years. Full data sets and cross-sectional images of contrast-enhanced computed tomography scan performed before EVAR, at the first postoperative month, at 24 or 36 months, and at 5-year follow-up interval will be reported in the central database for a centralized core laboratory review of morphological changes. The primary endpoint of the study is to evaluate the technical and clinical success of EVAR with the Alto stent graft in short- (90-day), mid- (1-year), and long-term (5-year) follow-up periods. The following secondary endpoints will be also addressed: operative time; intraoperative radiation exposure; contrast medium usage; AAA sac shrinkage at 12-month and 5-year follow-up; any potential role of patients' baseline characteristics, valuated on preoperative computed tomography angiographic study, and of device configuration (number of component) in the primary endpoint. Results: The study is currently in the recruitment phase and the final patient is expected to be treated by the end of 2023 and then followed up for 5 years. A total of 300 patients will be recruited. Analyses will focus on primary and secondary endpoints. Updated results will be shared at 1- and 3-5-year follow-ups. Conclusions: The results from this registry study could validate the safety and effectiveness of the new design of the Ovation Alto Stent Graft. The technical modifications to the endograft could allow for accommodation of a more comprehensive range of anatomies on-label

    Restenosis after Coronary and Peripheral Intervention: Efficacy and Clinical Impact of Cilostazol

    Get PDF
    Restenosis is one of the main complications in patients undergoing coronary or peripheral revascularization procedures and is the leading cause for their long-term failures. Cilostazol is the only pharmacotherapy that showed an adequate efficacy for preventing restenosis in randomized, controlled studies after coronary or peripheral revascularization procedures. The present review sums up the main clinical evidence supporting the use of cilostazol after revascularization interventions, focusing on all its benefits, warnings, and administration schedules

    Acute deep vein thrombosis and pulmonary embolism: is the thromboaspiration device an appropriate choice?

    Get PDF
    Nowadays patients affected by deep vein thrombosis (DVT) and pulmonary embolism (PE) are studied widely but the challenge for physicians is when and how they are to be treated. Most patients present serious comorbidities that can potentially make treatment difficult. An increasing cohort of patients cannot be treated with systemic fibrinolysis but fortunately today, physicians can utilize a number of different instruments to resolve acute DVT and PE

    Midterm results of proximal aneurysm sealing with the ovation stent-graft according to On-vs off-label use

    Get PDF
    Purpose: To compare the use of the Ovation stent-graft according to the â\u89¥7-mm neck length specified by the original instructions for use (IFU) vs those treated off-label (OL) for necks 2 mm). Results: At 3 years, there was no aneurysm-related death, rupture, stent-graft migration, or neck enlargement. There were no differences in terms of freedom from type Ia endoleak (98.2% IFU vs 96.8% OL, p=0.6; hazard ratio [HR] 0.55, 95% CI 0.02 to 9.71 or freedom from any device-related reintervention (92.8% IFU vs 96.4% OL, p=0.4; HR 2.42, 95% CI 0.34 to 12.99). In the sealing zone, the mean change in diameters was-0.05±0.8 mm in the IFU group and -0.1±0.5 mm in the OL group. Conclusion: Use of the Ovation stent-graft in patients with neck length <7 mm achieved midterm outcomes similar to patients with â\u89¥7-mm-long necks. These midterm data show that the use of the Ovation system for the treatment of infrarenal abdominal aortic aneurysm is not restricted by the conventional measurement of aortic neck length, affirming the recent Food and Drug Administration-approved changes to the IFU

    Focusing on diabetic ulcers

    Get PDF
    Foot ulcers associated with Diabetes mellitus require immediate attention due to risk of amputation if left untreated. Herein we focus on the mitigating risk factors and physiopathology of the diabetic foot, recounting our own surgical approach and revascularization procedures
    • …
    corecore