539 research outputs found

    Ion backflow studies with a triple-GEM stack with increasing hole pitch

    Full text link
    Gas Electron Multipliers have undergone a very consistent development since their invention in 1997. Their production procedures have been tuned in such a way that nowadays it is possible to produce foils with areas of the order of the square meter that can operate at a reasonable gain, uniform over large areas and with a good stability in what concerns electrical discharges. For the third run of LHC, they will be included in the CMS and ALICE experiments after significant upgrades of the detectors, confirming that these structures are suitable for very large experiments. In the special case of Time Projection Chambers, the ion backflow and the energy resolution are sensitive issues that must be addressed and the GEM has shown to be able to deal with both of them. In this work, a stack of three GEMs with different pitches has been studied as a possible future approach for ion-backflow suppression to be used in TPCs and other detection concepts. With this approach, an ion backflow of 1 % with an energy resolution of 12 % at 5.9 keV has been achieved with the detector operating in an Ar/CO2 (90/10) mixture at a gain of ~ 2000.Comment: 15 pages, 11 figure

    Micro-Hole and Strip Plate (MHSP) operation in CF4

    Get PDF
    The Micro-Hole and Strip Plate (MHSP) is a hybrid electron multiplier which combines the working principles of a Gas Electron Multiplier (GEM) and a Micro-Strip Gas Counter (MSGC). The compact double stage electron multiplication processes found in the MHSP enables the realisation of higher gas gain than the lone GEM operation. Thermal neutron detection using gas detectors involves the use of gas with another suitable stopping gas, operated at elevated pressure to confine the products of the neutron- reaction. It is, however, well known that the gain of GEMs drops too sharply with increasing chamber pressure.http://www.sciencedirect.com/science/article/B6TJM-4NS2G9V-D/1/497af6476b376b1c2f407a3fa7ff735

    First in-beam studies of a Resistive-Plate WELL gaseous multiplier

    Full text link
    We present the results of the first in-beam studies of a medium size (10×\times10 cm2^2) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity (\sim109Ω^9 \Omegacm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1×\times1 cm2^2 square copper pads with APV25-SRS readout electronics. The single-element detector was operated in Ne\(5% CH4\mathrm{CH_{4}}) at a gas gain of a few times 104^4, reaching 99%\% detection efficiency at average pad multiplicity of \sim1.2. Operation at particle fluxes up to \sim104^4 Hz/cm2^2 resulted in \sim23%\% gain drop leading to \sim5%\% efficiency loss. The striking feature was the discharge-free operation, also in intense pion beams. These results pave the way towards robust, efficient large-scale detectors for applications requiring economic solutions at moderate spatial and energy resolutions.Comment: Accepted by JINS

    Further studies on the gain properties of a Gas Electron Multiplier with a Micro-Induction Gap Amplifying Structure (GEM-MIGAS) aimed at low-energy X-ray detection

    Get PDF
    A Gas Electron Multiplier with Micro-Induction Gap Amplifying Structure (GEM-MIGAS) is formed when the induction gap of the GEM is set between 50 and 100 [mu]m using kapton pillars spaced at regular intervals. This configuration combines the properties of a GEM and Micromegas, allowing operation in tandem to generate high charge gains. We measured the essential operational parameters of this system using argon-isobutane (IB) and helium-IB gas mixtures. The present short induction gap GEM was able to achieve effective gains exceeding 2×104 using argon-IB and 105 using helium-IB mixtures. In view of the high gains achieved, particularly when using helium-based gas mixtures, these studies confirmed the possibility of using the present system for high-performance sub-keV X-ray detection.http://www.sciencedirect.com/science/article/B6TJM-4P61N30-5/1/fb32483bc2ec5006bc9641ac8675ee9

    Micromegas operation in high pressure xenon: charge and scintillation readout

    Full text link
    The operational characteristics of a Micromegas operating in pure xenon at the pressure range of 1 to 10 bar are investigated. The maximum charge gain achieved in each pressure is approximately constant, around 4x10^2, for xenon pressures up to 5 bar and decreasing slowly above this pressure down to values somewhat above 10^2 at 10 bar. The MM presents the highest gains for xenon pressures above 4 bar, when compared to other micropattern gaseous multipliers. The lowest energy resolution obtained for X-rays of 22.1 keV exhibits a steady increase with pressure, from 12% at 1bar to about 32% at 10 bar. The effective scintillation yield, defined as the number of photons exiting through the MM mesh holes per primary electron produced in the conversion region was calculated. This yield is about 2x10^2 photons per primary electron at 1 bar, increasing to about 6x10^2 at 5 bar and, then, decreasing again to 2x10^2 at 10 bar. The readout of this scintillation by a suitable photosensor will result in higher gains but with increased statistical fluctuations.Comment: 22 pages, 11 figure

    X-ray imaging with gaseous detectors using the VMM3a and the SRS

    Get PDF
    The integration of the VMM3a Application-Specific Integrated Circuit (ASIC) into RD51's Scalable Readout System (SRS) provides a versatile tool for the readout of Micro-Pattern Gaseous Detectors (MPGDs). With its self-triggered high-rate readout, its analogue part that allows to get information on the deposited energy in the detector, and its so-called neighbouring-logic that allows to recover information on the charge distribution, this new system has features of particular interest for digital X-ray imaging. In the present article, we want to emphasise the capabilities of VMM3a/SRS by presenting results of X-ray imaging studies. We will highlight the advantages on the energy and the spatial resolution provided by the neighbouring-logic. In the first part, we focus on spatial resolution studies. We show how segmented readout structures introduce a repeating pattern in the distribution of the reconstructed positions (using the centre-of-gravity method) and how this behaviour can be mitigated with the neighbouring-logic. As part of these studies, we explore as well an alternative position reconstruction algorithm. In the second part of the article, we present the energy resolution studies.Peer reviewe

    THGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation

    Get PDF
    We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1 cm2 readout pads. The detector is comprised of single- or double-THGEM multipliers coupled to the pad electrode either directly or via a resistive anode. Investigations employing standard discrete electronics and the KPiX readout system have been carried out both under laboratory conditions and with muons and pions at the CERN RD51 test beam. For detectors having a charge-induction gap, it has been shown that even a ~6 mm thick single-THGEM detector reached detection efficiencies above 95%, with pad-hit multiplicity of 1.1-1.2 per event; discharge probabilities were of the order of 1e-6 - 1e-5 sparks/trigger, depending on the detector structure and gain. Preliminary beam tests with a WELL hole-structure, closed by a resistive anode, yielded discharge probabilities of <2e-6 for an efficiency of ~95%. Methods are presented to reduce charge-spread and pad multiplicity with resistive anodes. The new method showed good prospects for further evaluation of very thin THGEM-based detectors as potential active elements for DHCAL, with competitive performances, simplicity and robustness. Further developments are in course.Comment: 15 pages, 11 figures, MPGD2011 conference proceedin

    Avoidance, biomass and survival response of soil dwelling (endogeic) earthworms to OECD artificial soil: potential implications for earthworm ecotoxicology

    Get PDF
    Soil dwelling earthworms are now adopted more widely in ecotoxicology, so it is vital to establish if standardised test parameters remain applicable. The main aim of this study was to determine the influence of OECD artificial soil on selected soil-dwelling, endogeic earthworm species. In an initial experiment, biomass change in mature Allolobophora chlorotica was recorded in Standard OECD Artificial Soil (AS) and also in Kettering Loam (KL). In a second experiment, avoidance behaviour was recorded in a linear gradient with varying proportions of AS and KL (100% AS, 75% AS + 25% KL, 50% KS + 50% KL, 25% AS + 75% KL, 100% KL) with either A. chlorotica or Octolasion cyaneum. Results showed a significant decrease in A. chlorotica biomass in AS relative to KL, and in the linear gradient, both earthworm species preferentially occupied sections containing higher proportions of KL over AS. Soil texture and specifically % composition and particle size of sand are proposed as key factors that influenced observed results. This research suggests that more suitable substrates are required for ecotoxicology tests with soil dwelling earthworms

    Operation of MHSP multipliers in high pressure pure noble-gas

    Full text link
    We report on the performance of a Micro-Hole & Strip Plate (MHSP) electron multiplier operating in pure Xe, Kr, Ar and Ne at the pressure range of 1 to 6 bar. The maximal gains at 1 bar Xe and Kr are 50000 and 100000, respectively; they drop by about one order of magnitude at 2 bar and by almost another order of magnitude at 5-6 bar; they reach gains of 500 and 4000 at 5 bar in Xe and Kr, respectively. In Ar, the gain varies very little with pressure, being 3000-9000; in Ne the maximum attainable gain, about 100000, is pressure independent above 2 bar. The results are compared with that of single- and triple-GEM multipliers operated in similar conditions. Potential applications are in hard X-ray imaging and in cryogenic radiation detectors.Comment: 16 pages, 4 figures. Submitted to JINST, 9 jan, 200
    corecore