Pressure and flow properties of dual-lumen cannulae for extracorporeal membrane oxygenation
Introduction: In the last decade, dual-lumen cannulae have been increasingly applied in patients undergoing extracorporeal life support. Well-performing vascular access is crucial for efficient extracorporeal membrane oxygenation support; thus, guidance for proper cannulae size is required. Pressure-flow charts provided by manufacturers are often based on tests performed using water, rarely blood. However, blood is a shear-thinning and viscoelastic fluid characterized by different flow properties than water. Methods: We performed a study evaluating pressure-flow curves during standardized conditions using human whole blood in two commonly available dual-lumen cannulae used in neonates, pediatric, and adult patients. Results were merged and compared with the manufacturer's corresponding curves obtained from the public domain. Results: The results showed that using blood as compared with water predominantly influenced drainage flow. A 10-80% higher pressure-drop was needed to obtain same drainage flow (hematocrit of 26%) compared with manufacturer's water charts in 13-31 Fr bi-caval dual-lumen cannulae. The same net difference was found in cavo-atrial cannulae (16-32 Fr), where a lower drainage pressure was required (Hct of 26%) compared with the manufacturer's test using blood with an Hct of 33%. Return pressure-flow data were similar, independent whether pumping blood or water, to the data reported by manufacturers. Conclusion: Non-standardized testing of pressure-flow properties of extracorporeal membrane oxygenation dual-lumen cannulae prevents an adequate prediction of pressure-flow results when these cannulae are used in patients. Properties of dual-lumen cannulae may vary between sizes within same cannula family, in particular concerning the drainage flow
Pressure and flow properties of cannulae for extracorporeal membrane oxygenation II:drainage (venous) cannulae
The use of extracorporeal life support devices such as extracorporeal membrane oxygenation in adults requires cannulation of the patient’s vessels with comparatively large diameter cannulae to allow circulation of large volumes of blood (>5 L/min). The cannula diameter and length are the major determinants for extracorporeal membrane oxygenation flow. Manufacturing companies present pressure-flow charts for the cannulae; however, these tests are performed with water. Aims of this study were 1. to investigate the specified pressure-flow charts obtained when using human blood as the circulating medium and 2. to support extracorporeal membrane oxygenation providers with pressure-flow data for correct choice of the cannula to reach an optimal flow with optimal hydrodynamic performance. Eighteen extracorporeal membrane oxygenation drainage cannulae, donated by the manufacturers (n = 6), were studied in a centrifugal pump driven mock loop. Pressure-flow properties and cannula features were described. The results showed that when blood with a hematocrit of 27% was used, the drainage pressure was consistently higher for a given flow (range 10%-350%) than when water was used (data from each respective manufacturer’s product information). It is concluded that the information provided by manufacturers in line with regulatory guidelines does not correspond to clinical performance and therefore may not provide the best guidance for clinicians.SCOPUS: ar.jinfo:eu-repo/semantics/publishe