14 research outputs found

    Concise methods for the synthesis of chiral polyoxazolines and their application in asymmetric hydrosilylation

    No full text
    Seven polyoxazoline ligands were synthesized in high yield in a one-pot reaction by heating polycarboxylic acids or their esters and chiral β-amino alcohols under reflux with concomitant removal of water or the alcohol produced in the reaction. The method is much simpler and more efficient in comparison to those methods reported in the literature

    Synthesis, Structure, and Dielectric Properties of (3-Nitroanilinium) (18-Crown) (PF6)

    No full text
    (3-Nitroanilinium) (18-crown) (PF6) (1), which is an organic-inorganic hybrid containing one-dimensional chains of hydrogen-bonded supramolecular cations, was synthesized under slow evaporation conditions and subjected to differential scanning calorimetry, temperature-dependent dielectric measurements, and variable-temperature single-crystal X-ray diffraction analysis. These analyses revealed the occurrence of a reversible structural phase transition [P21/n P21/c] at 223 K and a dielectric anomaly, which, based on the results of structural analysis and potential energy calculations, was attributed to the synergistic effect between the pendulum-like motion of the nitro group in the supramolecular cation, (3-nitroanilinium)(18-crown), and the order-disorder motion of PF6− anions

    Recommended Implementation of Arterial Spin-Labeled Perfusion MRI for Clinical Applications : A Consensus of the ISMRM Perfusion Study Group and the European Consortium for ASL in Dementia

    No full text
    This review provides a summary statement of recommended implementations of arterial spin labeling (ASL) for clinical applications. It is a consensus of the ISMRM Perfusion Study Group and the European ASL in Dementia consortium, both of whom met to reach this consensus in October 2012 in Amsterdam. Although ASL continues to undergo rapid technical development, we believe that current ASL methods are robust and ready to provide useful clinical information, and that a consensus statement on recommended implementations will help the clinical community to adopt a standardized approach. In this review, we describe the major considerations and trade-offs in implementing an ASL protocol and provide specific recommendations for a standard approach. Our conclusion is that as an optimal default implementation, we recommend pseudo-continuous labeling, background suppression, a segmented three-dimensional readout without vascular crushing gradients, and calculation and presentation of both label/control difference images and cerebral blood flow in absolute units using a simplified model. Magn Reson Med 73:102-116, 2015. (c) 2014 Wiley Periodicals, Inc

    Erratum to: Guidelines for the use and interpretation of assays for monitoring autophagy (3rd edition) (Autophagy, 12, 1, 1-222, 10.1080/15548627.2015.1100356

    No full text
    non present
    corecore