104 research outputs found

    Lack of Cardiac Nerve Sprouting after Intramyocardial Transplantation of Bone Marrow-Derived Stem Cells in a Swine Model of Chronic Ischemic Myocardium

    Get PDF
    Previous experimental studies suggested that mesenchymal stem cell transplantation causes cardiac nerve sprouting; however, whether bone marrow (BM)-derived mononuclear cells (MNC) and endothelial progenitor cells (EPC) can also lead to cardiac nerve sprouting and alter gap junction expression remains unclear. We investigated the effect of electroanatomical mapping-guided direct intramyocardial transplantation of BM-MNC (n = 8) and CD31+EPC (n = 8) compared with saline control (n = 8) on cardiac nerve sprouting and gap junction expression in a swine model of chronic ischemic myocardium. At 12 weeks after transplantation, the distribution and density of cardiac nerve sprouting were determined by staining of tyrosine hydroxylase (TH) and growth associated protein 43(GAP-43) and expression of connexin 43 in the targeted ischemic and remote normal myocardium. After 12 weeks, no animal developed sudden death after the transplantation. There were no significant differences in the number of cells with positive staining of TH and GAP-43 in the ischemic and normal myocardium between three groups. Furthermore, expression of connexin 43 was also similar in the ischemic and normal myocardia in each group of animals (P > 0.05). The results of this study demonstrated that intramyocardial BM-derived MNC or EPC transplantation in a large animal model of chronic myocardial ischemia was not associated with increased cardiac nerve sprouting over the ischemic myocardium

    Specification and guideline for technical aspects and scanning parameter settings of neonatal lung ultrasound examination

    Get PDF
    Lung ultrasound (LUS) is now widely used in the diagnosis and monitor of neonatal lung diseases.Nevertheless, in the published literatures,the LUS images may display a significant variation in technical execution,while scanning parameters may influence diagnostic accuracy.The inter- and intra-observer reliabilities of ultrasound exam have been extensively studied in general and in LUS.As expected,the reliability declines in the hands of novices when they perform the point-of-care ultrasound (POC US).Consequently,having appropriate guidelines regarding to technical aspects of neonatal LUS exam is very important especially because diagnosis is mainly based on interpretation of artifacts produced by the pleural line and the lungs.The present work aimed to create an instrument operation specification and parameter setting guidelines for neonatal LUS.Technical aspects and scanning parameter settings that allow for standardization in obtaining LUS images include (1)select a high-end equipment with high-frequency linear array transducer (12-14 MHz).(2)Choose preset suitable for lung examination or small organs.(3)Keep the probe perpendicular to the ribs or parallel to the intercostal space.(4)Set the scanning depth at 4-5 cm.(5)Set 1-2 focal zones and adjust them close to the pleural line.(6)Use fundamental frequency with speckle reduction 2-3 or similar techniques.(7)Turn off spatial compounding imaging.(8)Adjust the time-gain compensation to get uniform image from the near-to far-field

    Effect of Hypoxia on Expression of Selected Proteins Involved in Regulation of Apoptotic Activity in Striatum of Newborn Piglets

    Get PDF
    The levels of selected neuroregulatory proteins that inhibit or promote apoptotic cell death were measured in the striatum of piglets subjected to precisely controlled 1 h hypoxic insult followed by 0, 2 and 4 h recovery and compared to sham operated animals. The anti-apoptotic proteins: there were increases in Survivin at 0 (157%, P = 0.031) and 4 h (171%, P = 0.033), in Bcl-XL at 0 (138%, P = 0.028) and 4 h (143%, P = 0.007), in VEGF at 4 h (185%, P = 0.019) and Hsp27 at 2 h (144%, P = 0.05) and 4 h (143%, P = 0.05). The pro-apoptotic proteins: caspases-1 and 7 increased at 4 h (135%, P = 0.05) and (129%, P = 0.038), respectively. Bim increased after 4 h (115%, P = 0.028), Apoptosis Inducing Factor after 2 h (127%, P = 0.048) and Calpain after 4 h (143% of control, P = 0.04). Hypoxia causes increase in levels of both anti- and pro-apoptotic proteins. Their relative activity determines the outcome in terms of cell damage and neuronal deficit

    Beam-Target Double Spin Asymmetry A_LT in Charged Pion Production from Deep Inelastic Scattering on a Transversely Polarized He-3 Target at 1.4<Q^2<2.7 GeV^2

    Full text link
    We report the first measurement of the double-spin asymmetry ALTA_{LT} for charged pion electroproduction in semi\nobreakdash-inclusive deep\nobreakdash-inelastic electron scattering on a transversely polarized 3^{3}He target. The kinematics focused on the valence quark region, 0.16<x<0.350.16<x<0.35 with 1.4<Q2<2.7GeV21.4<Q^{2}<2.7\,\textrm{GeV}^{2}. The corresponding neutron ALTA_{LT} asymmetries were extracted from the measured 3^{3}He asymmetries and proton over 3^{3}He cross section ratios using the effective polarization approximation. These new data probe the transverse momentum dependent parton distribution function g1Tqg_{1T}^{q} and therefore provide access to quark spin-orbit correlations. Our results indicate a positive azimuthal asymmetry for π\pi^{-} production on 3^{3}He and the neutron, while our π+\pi^{+} asymmetries are consistent with zero.Comment: 6 pages, 2 figures, 1 tables, published in PR

    Single Spin Asymmetries in Charged Pion Production from Semi-Inclusive Deep Inelastic Scattering on a Transversely Polarized 3^3He Target

    Full text link
    We report the first measurement of target single spin asymmetries in the semi-inclusive 3He(e,eπ±)X^3{He}(e,e'\pi^\pm)X reaction on a transversely polarized target. The experiment, conducted at Jefferson Lab using a 5.9 GeV electron beam, covers a range of 0.14 <x<< x < 0.34 with 1.3 <Q2<<Q^2< 2.7 GeV2^2. The Collins and Sivers moments were extracted from the azimuthal angular dependence of the measured asymmetries. The extracted π±\pi^\pm Collins moments for 3^3He are consistent with zero, except for the π+\pi^+ moment at x=0.34x=0.34, which deviates from zero by 2.3σ\sigma. While the π\pi^- Sivers moments are consistent with zero, the π+\pi^+ Sivers moments favor negative values. The neutron results were extracted using the nucleon effective polarization and the measured cross section ratio of proton to 3^3He, and are largely consistent with the predictions of phenomenological fits and quark model calculations.Comment: 6 pages, 2 figures, 2 tables, published in PR

    The Role of Purported Mucoprotectants in Dealing with Irritable Bowel Syndrome, Functional Diarrhea, and Other Chronic Diarrheal Disorders in Adults

    Get PDF
    Chronic diarrhea is a frequent presenting symptom, both in primary care medicine and in specialized gastroenterology units. It is estimated that more than 5% of the global population suffers from chronic diarrhea. and that about 40% of these subjects are older than 60 years. The clinician is frequently faced with the need to decide which is the best therapeutic approach for these patients. While the origin of chronic diarrhea is diverse, impairment of intestinal barrier function, dysbiosis. and mucosal micro-inflammation are being increasingly recognized as underlying phenomena characterizing a variety of chronic diarrheal diseases. In addition to current pharmacological therapies, there is growing interest in alternative products such as mucoprotectants, which form a mucoadhesive film over the epithelium to reduce and protect against the development of altered intestinal permeability, dysbiosis, and mucosal micro-inflammation. This manuscript focuses on chronic diarrhea in adults, and we will review recent evidence on the ability of these natural compounds to improve symptoms associated with chronic diarrhea and to exert protective effects for the intestinal barrier

    Cerebral ischemic damage in diabetes: an inflammatory perspective

    Get PDF
    corecore