651 research outputs found

    Compatibility of the Radio Frequency Mass Gauge with Graphite-Epoxy Composite Tanks

    Get PDF
    The radio frequency mass gauge (RFMG) is a low-gravity propellant quantity gauge being developed at NASA for possible use in long-duration space missions utilizing cryogenic propellants. As part of the RFMG technology development process, we evaluated the compatibility of the RFMG with a graphite-epoxy composite material used to construct propellant tanks. The key material property that can affect compatibility with the RFMG is the electrical conductivity. Using samples of 8552/IM7 graphite-epoxy composite, we characterized the resistivity and reflectivity over a range of frequencies. An RF impedance analyzer was used to characterize the out-of-plane electrical properties (along the sample thickness) in the frequency range 10 to 1800 MHZ. The resistivity value at 500 MHz was 4.8 ohm-cm. Microwave waveguide measurements of samples in the range 1.7 - 2.6 GHz, performed by inserting the samples into a WR-430 waveguide, showed reflectivity values above 98%. Together, these results suggested that a tank constructed from graphite/epoxy composite would produce good quality electromagnetic tank modes, which is needed for the RFMG. This was verified by room-temperature measurements of the electromagnetic modes of a 2.4 m diameter tank constructed by Boeing from similar graphite-epoxy composite material. The quality factor Q of the tank electromagnetic modes, measured via RF reflection measurements from an antenna mounted in the tank, was typically in the range 400 less than Q less than 3000. The good quality modes observed in the tank indicate that the RFMG is compatible with graphite-epoxy tanks, and thus the RFMG could be used as a low-gravity propellant quantity gauge in such tanks filled with cryogenic propellants

    Dephasing of coupled spin qubit system during gate operations due to background charge fluctuations

    Full text link
    It has been proposed that a quantum computer can be constructed based on electron spins in quantum dots or based on a superconducting nanocircuit. During two-qubit operations, the fluctuation of the coupling parameters is a critical factor. One source of such fluctuation is the stirring of the background charges. We focused on the influence of this fluctuation on a coupled spin qubit system. The induced fluctuation in exchange coupling changes the amount of entanglement, fidelity, and purity. In our previous study, the background charge fluctuations were found to be an important channel of dephasing for a single Josephson qubit.Comment: 10 pages, 7 figure. to be publishe

    Two-Photon Fluorescence Microscopy Developed for Microgravity Fluid Physics

    Get PDF
    Recent research efforts within the Microgravity Fluid Physics Branch of the NASA Glenn Research Center have necessitated the development of a microscope capable of high-resolution, three-dimensional imaging of intracellular structure and tissue morphology. Standard optical microscopy works well for thin samples, but it does not allow the imaging of thick samples because of severe degradation caused by out-of-focus object structure. Confocal microscopy, which is a laser-based scanning microscopy, provides improved three-dimensional imaging and true optical sectioning by excluding the out-of-focus light. However, in confocal microscopy, out-of-focus object structure is still illuminated by the incoming beam, which can lead to substantial photo-bleaching. In addition, confocal microscopy is plagued by limited penetration depth, signal loss due to the presence of a confocal pinhole, and the possibility of live-cell damage. Two-photon microscopy is a novel form of laser-based scanning microscopy that allows three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon microscopy, it utilizes the nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption because of the nonlinear (i.e., quadratic) electric field dependence, so an ultrafast pulsed laser source must typically be employed. On the other hand, this stringent energy density requirement effectively localizes fluorophore excitation to the focal volume. Consequently, two-photon microscopy provides optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction in photo-damage because of the longer excitation wavelength, a reduction in background fluorescence, and a 4 increase in penetration depth over confocal methods because of the reduction in Rayleigh scattering

    Quantum critical states and phase transitions in the presence of non equilibrium noise

    Get PDF
    Quantum critical points are characterized by scale invariant correlations and correspondingly long ranged entanglement. As such, they present fascinating examples of quantum states of matter, the study of which has been an important theme in modern physics. Nevertheless very little is known about the fate of quantum criticality under non equilibrium conditions. In this paper we investigate the effect of external noise sources on quantum critical points. It is natural to expect that noise will have a similar effect to finite temperature, destroying the subtle correlations underlying the quantum critical behavior. Surprisingly we find that in many interesting situations the ubiquitous 1/f noise preserves the critical correlations. The emergent states show intriguing interplay of intrinsic quantum critical and external noise driven fluctuations. We demonstrate this general phenomenon with specific examples in solid state and ultracold atomic systems. Moreover our approach shows that genuine quantum phase transitions can exist even under non equilibrium conditions.Comment: 9 pages, 2 figure

    Alterations in vascular function in primary aldosteronism - a cardiovascular magnetic resonance imaging study

    Get PDF
    Introduction: Excess aldosterone is associated with increased cardiovascular risk. Aldosterone has a permissive effect on vascular fibrosis. Cardiovascular magnetic resonance imaging (CMR) allows study of vascular function by measuring aortic distensibility. We compared aortic distensibility in primary aldosteronism (PA), essential hypertension (EH) and normal controls and explored the relationship between aortic distensibility and pulse wave velocity (PWV).<p></p> Methods: We studied PA (n=14) and EH (n=33) subjects and age-matched healthy controls (n=17) with CMR, including measurement of aortic distensibility, and measured PWV using applanation tonometry. At recruitment, PA and EH patients had similar blood pressure and left ventricular mass.<p></p> Results: Subjects with PA had significantly lower aortic distensibilty and higher PWV compared to EH and healthy controls. These changes were independent of other factors associated with reduced aortic distensibility, including aging. There was a significant relationship between increasing aortic stiffness and age in keeping with physical and vascular aging. As expected, aortic distensibility and PWV were closely correlated.<p></p> Conclusion: These results demonstrate that PA patients display increased arterial stiffness compared to EH, independent of vascular aging. The implication is that aldosterone invokes functional impairment of arterial function. The long-term implications of arterial stiffening in aldosterone excess require further study.<p></p&gt

    Dephasing of Electrons by Two-Level Defects in Quantum Dots

    Full text link
    The electron dephasing time τϕ\tau_{\phi} in a diffusive quantum dot is calculated by considering the interaction between the electron and dynamical defects, modelled as two-level system. Using the standard tunneling model of glasses, we obtain a linear temperature dependence of 1/τϕ1/\tau_{\phi}, consistent with the experimental observation. However, we find that, in order to obtain dephasing times on the order of nanoseconds, the number of two-level defects needs to be substantially larger than the typical concentration in glasses. We also find a finite system-size dependence of τϕ\tau_{\phi}, which can be used to probe the effectiveness of surface-aggregated defects.Comment: two-column 9 page

    Quantum Films Adsorbed on Graphite: Third and Fourth Helium Layers

    Full text link
    Using a path-integral Monte Carlo method for simulating superfluid quantum films, we investigate helium layers adsorbed on a substrate consisting of graphite plus two solid helium layers. Our results for the promotion densities and the dependence of the superfluid density on coverage are in agreement with experiment. We can also explain certain features of the measured heat capacity as a function of temperature and coverage.Comment: 13 pages in the Phys. Rev. two-column format, 16 Figure

    Single and double qubit gates by manipulating degeneracy

    Full text link
    A novel mechanism is proposed for single and double qubit state manipulations in quantum computation with four-fold degenerate energy levels. The principle is based on starting with a four fold degeneracy, lifting it stepwise adiabatically by a set of control parameters and performing the quantum gate operations on non-degenerate states. A particular realization of the proposed mechanism is suggested by using inductively coupled rf-squid loops in the macroscopic quantum tunnelling regime where the energy eigen levels are directly connected with the measurable flux states. The one qubit and two qubit controlled operations are demonstrated explicitly. The appearance of the flux states also allows precise read-in and read-out operations by the measurement of flux.Comment: 6 pages + 5 figures (separately included

    Localized helium excitations in 4He_N-benzene clusters

    Full text link
    We compute ground and excited state properties of small helium clusters 4He_N containing a single benzene impurity molecule. Ground-state structures and energies are obtained for N=1,2,3,14 from importance-sampled, rigid-body diffusion Monte Carlo (DMC). Excited state energies due to helium vibrational motion near the molecule surface are evaluated using the projection operator, imaginary time spectral evolution (POITSE) method. We find excitation energies of up to ~23 K above the ground state. These states all possess vibrational character of helium atoms in a highly anisotropic potential due to the aromatic molecule, and can be categorized in terms of localized and collective vibrational modes. These results appear to provide precursors for a transition from localized to collective helium excitations at molecular nanosubstrates of increasing size. We discuss the implications of these results for analysis of anomalous spectral features in recent spectroscopic studies of large aromatic molecules in helium clusters.Comment: 15 pages, 5 figures, submitted to Phys. Rev.
    corecore