138 research outputs found

    Eotaxin-1 in exhaled breath condensate of stable and unstable asthma patients.

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Airway eosinophilia is considered a central event in the pathogenesis of asthma. Eotaxin plays a key role in selective eosinophil accumulation in the airways and, subsequently, their activation and degranulation. The study was undertaken to evaluate eotaxin-1 levels in the exhaled breath condensate (EBC) of asthmatics with different degrees of asthma severity and to establish the possible correlation of these measurements with other recognized parameters of airway inflammation.</p> <p>Methods</p> <p>EBC was collected from 46 patients with allergic asthma (14 with steroid-naïve asthma, 16 with ICS-treated, stable asthma, 16 with ICS-treated unstable asthma) and 12 healthy volunteers. Concentrations of eotaxin-1 were measured by ELISA.</p> <p>Results</p> <p>In the three groups of asthmatics, eotaxin-1 concentrations in EBC were significantly higher compared with healthy volunteers (steroid-naïve asthma: 9.70 pg/ml ± 1.70, stable ICS-treated asthma: 10.45 ± 2.00, unstable ICS-treated asthma: 17.97 ± 3.60, healthy volunteers: 6.24 ± 0.70). Eotaxin-1 levels were significantly higher in patients with unstable asthma than in the two groups with stable disease. We observed statistically significant correlations between the concentrations of eotaxin-1 in EBC and exhaled nitric oxide (F<sub>ENO</sub>) or serum eosinophil cationic protein (ECP) in the three studied groups of asthmatics. We also discovered a significantly positive correlation between eotaxin-1 in EBC and blood eosinophil count in the groups of patients with unstable asthma and steroid-naïve asthma.</p> <p>Conclusions</p> <p>Measurements of eotaxin-1 in the EBC of asthma patients may provide another useful diagnostic tool for detecting and monitoring airway inflammation and disease severity.</p

    Exhaled nitric oxide in the diagnosis of asthma in adults: a systematic review.

    Get PDF
    OBJECTIVES: To identify and synthesise evidence on the diagnostic accuracy of FE NO for asthma in adults. MATERIALS AND METHODS: Systematic searches (nine key biomedical databases and trial registers) were carried out to November 2014. Records were included if they: recruited patients with the symptoms of asthma; used a single set of inclusion criteria; measured FE NO50 in accordance with American Thoracic Society guidelines, 2005 (off-line excluded); reported/allowed calculation of true positive, true negative, false positive and false negative patients as classified against any reference standard. Study quality was assessed using QUADAS II. Meta-analysis was planned where clinical study heterogeneity allowed. Rule-in and Rule-out uses of FE NO were considered. RESULTS: 4861 records were identified originally and 1312 in an update. 27 studies were included. Heterogeneity precluded meta-analysis. Results varied even within subgroups of studies. Cut-off values for the best sum of sensitivity and specificity varied from 12ppb to 55ppb, but did not produce high accuracy. 100% sensitivity or 100% specificity were reported by some studies indicating potential use as a rule-in or rule-out strategy. CONCLUSIONS: FE NO50 had variable diagnostic accuracy even within subgroups of studies with similar characteristics. Diagnostic accuracy, optimal cut-off values and best position for FE NO50 within a pathway remain poorly evidenced. This article is protected by copyright. All rights reserved

    Endothelin-1 in exhaled breath condensate of allergic asthma patients with exercise-induced bronchoconstriction

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Exercise-induced bronchoconstriction (EIB) is a highly prevalent condition, whose pathophysiology is not well understood. Endothelins are proinflammatory, profibrotic, broncho- and vasoconstrictive peptides which play an important role in the development of airway inflammation and remodeling in asthma. The aim of the study was to evaluate the changes in endothelin-1 levels in exhaled breath condensate following intensive exercise in asthmatic patients.</p> <p>Methods</p> <p>The study was conducted in a group of 19 asthmatic patients (11 with EIB, 8 without EIB) and 7 healthy volunteers. Changes induced by intensive exercise in the concentrations of endothelin-1 (ET-1) in exhaled breath condensate (EBC) during 24 hours after an exercise challenge test were determined. Moreover, the possible correlations of these measurements with the results of other tests commonly associated with asthma and with the changes of airway inflammation after exercise were observed.</p> <p>Results</p> <p>In asthmatic patients with EIB a statistically significant increase in the concentration of ET-1 in EBC collected between 10 minutes and 6 hours after an exercise test was observed. The concentration of ET-1 had returned to its initial level 24 hours after exercise. No effects of the exercise test on changes in the concentrations of ET-1 in EBC in either asthmatic patients without EIB or healthy volunteers were observed. A statistically significant correlation between the maximum increase in ET-1 concentrations in EBC after exercise and either baseline F<sub>ENO </sub>and the increase in F<sub>ENO </sub>or BHR to histamine 24 hours after exercise in the groups of asthmatics with EIB was revealed.</p> <p>Conclusion</p> <p>The release of ET-1 from bronchial epithelium through the influence of many inflammatory cells essential in asthma and interactions with other cytokines, may play an important role in increase of airway inflammation which was observed after postexercise bronchoconstriction in asthmatic patients.</p

    Associations of airway inflammation and responsiveness markers in non asthmatic subjects at start of apprenticeship

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Bronchial Hyperresponsiveness (BHR) is considered a hallmark of asthma. Other methods are helpful in epidemiological respiratory health studies including Fractional Exhaled Nitric Oxide (FENO) and Eosinophils Percentage (EP) in nasal lavage fluid measuring markers for airway inflammation along with the Forced Oscillatory Technique measuring Airway resistance (AR). Can their outcomes discriminate profiles of respiratory health in healthy subjects starting apprenticeship in occupations with a risk of asthma?</p> <p>Methods</p> <p>Rhinoconjunctivitis, asthma-like symptoms, FEV1 and AR post-Methacholine Bronchial Challenge (MBC) test results, FENO measurements and EP were all investigated in apprentice bakers, pastry-makers and hairdressers not suffering from asthma. Multiple Correspondence Analysis (MCA) was simultaneously conducted in relation to these groups and this generated a synthetic partition (EI). Associations between groups of subjects based on BHR and EI respectively, as well as risk factors, symptoms and investigations were also assessed.</p> <p>Results</p> <p>Among the 441 apprentice subjects, 45 (10%) declared rhinoconjunctivitis-like symptoms, 18 (4%) declared asthma-like symptoms and 26 (6%) suffered from BHR. The mean increase in AR post-MBC test was 21% (sd = 20.8%). The median of FENO values was 12.6 ppb (2.6-132 range). Twenty-six subjects (6.7%) had EP exceeding 14%. BHR was associated with atopy (p < 0.01) and highest FENO values (p = 0.09). EI identified 39 subjects with eosinophilic inflammation (highest values of FENO and eosinophils), which was associated with BHR and atopy.</p> <p>Conclusions</p> <p>Are any of the identified markers predictive of increased inflammatory responsiveness or of development of symptoms caused by occupational exposures? Analysis of population follow-up will attempt to answer this question.</p

    Exhaled and arterial levels of endothelin-1 are increased and correlate with pulmonary systolic pressure in COPD with pulmonary hypertension

    Get PDF
    BACKGROUND: Endothelin-1 (ET-1) and Nitric Oxide (NO) are crucial mediators for establishing pulmonary artery hypertension (PAH). We tested the hypothesis that their imbalance might also occur in COPD patients with PAH. METHODS: The aims of the study were to measure exhaled breath condensate (EBC) and circulating levels of ET-1, as well as exhaled NO (FENO) levels by, respectively, a specific enzyme immunoassay kit, and by chemiluminescence analysis in 3 groups of subjects: COPD with PAH (12), COPD only (36), and healthy individuals (15). In order to evaluate pulmonary-artery systolic pressure (PaPs), all COPD patients underwent Echo-Doppler assessment. RESULTS: Significantly increased exhaled and circulating levels of ET-1 were found in COPD with PAH compared to both COPD (p < 0.0001) only, and healthy controls (p < 0.0001). In COPD with PAH, linear regression analysis showed good correlation between ET-1 in EBC and PaPs (r = 0.621; p = 0.031), and between arterial levels of ET-1 and PaPs (r = 0.648; p = 0.022), while arterial levels of ET-1 inversely correlated with FEV1%, (r = -0.59, p = 0.043), and PaPs negatively correlated to PaO2 (r = -0.618; p = 0.032). Significantly reduced levels of FENO were found in COPD associated with PAH, compared to COPD only (22.92 +/- 11.38 vs.35.07 +/- 17.53 ppb; p = 0.03). Thus, we observed an imbalanced output in the breath between ET-1 and NO, as expression of pulmonary endothelium and epithelium impairment, in COPD with PAH compared to COPD only. Whether this imbalance is an early cause or result of PAH due to COPD is still unknown and deserves further investigations

    FDA Critical Path Initiatives: Opportunities for Generic Drug Development

    Get PDF
    FDA’s critical path initiative documents have focused on the challenges involved in the development of new drugs. Some of the focus areas identified apply equally to the production of generic drugs. However, there are scientific challenges unique to the development of generic drugs as well. In May 2007, FDA released a document “Critical Path Opportunities for Generic Drugs” that identified some of the specific challenges in the development of generic drugs. The key steps in generic product development are usually characterization of the reference product, design of a pharmaceutically equivalent and bioequivalent product, design of a consistent manufacturing process and conduct of the pivotal bioequivalence study. There are several areas of opportunity where scientific progress could accelerate the development and approval of generic products and expand the range of products for which generic versions are available, while maintaining high standards for quality, safety, and efficacy. These areas include the use of quality by design to develop bioequivalent products, more efficient bioequivalence methods for systemically acting drugs (expansion of BCS waivers, highly variable drugs), and development of new bioequivalence methods for locally acting drugs

    NIOX VERO: Individualized Asthma Management in Clinical Practice

    Get PDF
    As we move toward an era of precision medicine, novel biomarkers of disease will enable the identification and personalized treatment of new endotypes. In asthma, fractional exhaled nitric oxide (FeNO) serves as a surrogate marker of airway inflammation that often correlates with the presence of sputum eosinophils. The increase in FeNO is driven by an upregulation of inducible nitric oxide synthase (iNOS) by cytokines, which are released as a result of type-2 airway inflammation. Scientific evidence supports using FeNO in routine clinical practice. In steroid-naive patients and in patients with mild asthma, FeNO levels decrease within days after corticosteroid treatment in a dose-dependent fashion and increase after steroid withdrawal. In difficult asthma, FeNO testing correlates with anti-inflammatory therapy compliance. Assessing adherence by FeNO testing can remove the confrontational aspect of questioning a patient about compliance and change the conversation to one of goal setting and ways to improve disease management. However, the most important aspect of incorporating FeNO in asthma management is the reduction in the risk of exacerbations. In a recent primary care study, reduction of exacerbation rates and improved symptom control without increasing overall inhaled corticosteroid (ICS) use were demonstrated when a FeNO-guided anti-inflammatory treatment algorithm was assessed and compared to the standard care. A truly personalized asthma management approach—showing reduction of exacerbation rates, overall use of ICS and neonatal hospitalizations—was demonstrated when FeNO testing was applied as part of the treatment algorithm that managed asthma during pregnancy. The aim of this article is to describe how FeNO and the NIOX VERO® analyzer can help to optimize diagnosis and treatment choices and to aid in the monitoring and improvement of clinical asthma outcomes in children and adults

    Systematic review with meta-analysis of the epidemiological evidence relating smoking to COPD, chronic bronchitis and emphysema

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Smoking is a known cause of the outcomes COPD, chronic bronchitis (CB) and emphysema, but no previous systematic review exists. We summarize evidence for various smoking indices.</p> <p>Methods</p> <p>Based on MEDLINE searches and other sources we obtained papers published to 2006 describing epidemiological studies relating incidence or prevalence of these outcomes to smoking. Studies in children or adolescents, or in populations at high respiratory disease risk or with co-existing diseases were excluded. Study-specific data were extracted on design, exposures and outcomes considered, and confounder adjustment. For each outcome RRs/ORs and 95% CIs were extracted for ever, current and ex smoking and various dose response indices, and meta-analyses and meta-regressions conducted to determine how relationships were modified by various study and RR characteristics.</p> <p>Results</p> <p>Of 218 studies identified, 133 provide data for COPD, 101 for CB and 28 for emphysema. RR estimates are markedly heterogeneous. Based on random-effects meta-analyses of most-adjusted RR/ORs, estimates are elevated for ever smoking (COPD 2.89, CI 2.63-3.17, n = 129 RRs; CB 2.69, 2.50-2.90, n = 114; emphysema 4.51, 3.38-6.02, n = 28), current smoking (COPD 3.51, 3.08-3.99; CB 3.41, 3.13-3.72; emphysema 4.87, 2.83-8.41) and ex smoking (COPD 2.35, 2.11-2.63; CB 1.63, 1.50-1.78; emphysema 3.52, 2.51-4.94). For COPD, RRs are higher for males, for studies conducted in North America, for cigarette smoking rather than any product smoking, and where the unexposed base is never smoking any product, and are markedly lower when asthma is included in the COPD definition. Variations by sex, continent, smoking product and unexposed group are in the same direction for CB, but less clearly demonstrated. For all outcomes RRs are higher when based on mortality, and for COPD are markedly lower when based on lung function. For all outcomes, risk increases with amount smoked and pack-years. Limited data show risk decreases with increasing starting age for COPD and CB and with increasing quitting duration for COPD. No clear relationship is seen with duration of smoking.</p> <p>Conclusions</p> <p>The results confirm and quantify the causal relationships with smoking.</p
    corecore