2,247 research outputs found

    Source population synthesis and the Galactic diffuse gamma-ray emission

    Get PDF
    Population synthesis is used to study the contribution from undetected sources to the Galactic ridge emission measured by EGRET. Synthesized source counts are compared with the 3rd EGRET catalogue at low and high latitudes. For pulsar-like populations, 5-10% of the emission >100 MeV comes from sources below the EGRET threshold. A steeper luminosity function can increase this to 20% without violating EGRET source statistics. Less luminous populations can produce much higher values without being detected. Since the unresolved source spectrum is different from the interstellar spectrum, it could provide an explanation of the observed MeV and GeV excesses above the predictions, and we give an explicit example of how this could work.Comment: Astrophysics and Space Science, in press. (Proceedings of Conference 'The multi-messenger approach to high-energy gamma-ray sources', Barcelona, 2006). Minor changes for accepted version, updated reference

    Seedling salt tolerance in tomato

    Get PDF
    Soils with higher concentrations of salt are becoming more and more a constraint for many crops to obtain high yields. Wild tomato species, adapted to adverse environments, are a potential reservoir for genes underlying quantitative trait loci (QTL) related to salt tolerance in tomato. In this study two introgression line (IL) libraries derived from two different wild species, Solanum pennellii LA716 and Solanum lycopersicoides LA2951, were used to identify QTLs for salt tolerance in the seedling stage. In the S. pennellii IL library, four major QTLs were identified on chromosomes 6, 7 and 11. In the S. lycopersicoides IL library, six major QTLs were discovered which are located on chromosomes 4, 6, 9 and 12. Co-localization of QTLs on chromosome 6 in the two IL libraries and previously reports hinted that this locus might be conserved in the tomato crop. Three S. pennellii ILs (IL6-2, IL7-1 and IL7-5) harboring QTLs on chromosome 6 and 7 were crossed. Semi-dominance and dominance were shown for these three QTLs, and non-additive and epistatic interactions between them were observe

    Energy Efficiency Improvements in Dry Drilling with Optimised Diamond-Like Carbon Coating

    Get PDF
    We demonstrate enhancements of performance and energy efficiency of cutting tools by deposition of diamond-like carbon (DLC) coatings on machine parts. DLC was deposited on steel drill bits, using plasma enhanced chemical vapour deposition (PECVD) with the acetylene precursor diluted with argon, to produce a surface with low friction and low wear rate. Drill bit performance in dry drilling of aluminium was quantified by analysis of power consumption and swarf flow. Optimised deposition conditions produced drill bits with greatly enhanced performance over uncoated drill bits, showing a 25% reduction in swarf clogging, a 36% reduction in power consumption and a greater than five-fold increase in lifetime. Surface analysis with scanning electron microscopy shows that DLC coated drills exhibit much lower aluminium build up on the trailing shank of the drill, enhancing the anti-adhering properties of the drill and reducing heat generation during operation, resulting in the observed improvements in efficiency. Variation of drilling efficiency with argon dilution of precursor is related to changes in the microstructure of the DLC coating

    Influence of the electrode gap separation on the pseudospark-sourced electron beam generation

    Get PDF
    Pseudospark-sourced electron beam is a self-focused intense electron beam which can propagate without any external focusing magnetic field. This electron beam can drive a beam-wave interaction directly or after being post-accelerated. It is especially suitable for terahertz (THz) radiation generation due to the ability of a pseudospark discharge to produce small size in the micron range and very high current density and bright electron beams. In this paper, a single-gap pseudospark discharge chamber has been built and tested with several electrode gap separations to explore the dependence of the pseudospark-sourced electron beam current on the discharge voltage and the electrode gap separation. Experimental results show that the beam pulses have similar pulse width and delay time from the distinct drop of the applied voltage for smaller electrode gap separations but longer delay time for the largest gap separation used in the experiment. It has been found that the electron beam only starts to occur when the charging voltage is above a certain value, which is defined as the starting voltage of the electron beam. The starting voltage is different for different electrode gap separations and decreases with increasing electrode gap separation in our pseudospark discharge configuration. The electron beam current increases with the increasing discharge voltage following two tendencies. Under the same discharge voltage, the configuration with the larger electrode gap separation will generate higher electron beam current. When the discharge voltage is higher than 10 kV, the beam current generated at the electrode gap separation of 17.0 mm, is much higher than that generated at smaller gap separations. The ionization of the neutral gas in the main gap is inferred to contribute more to the current increase with increasing electrode gap separation

    The CompactLight design study

    Get PDF
    The H₂020 CompactLight Project (www. CompactLight.eu) aims at designing the next generation of compact X-rays Free-Electron Lasers, relying on very high gradient accelerating structures (X-band, 12 GHz), the most advanced concepts for bright electron photo injectors, and innovative compact short-period undulators. Compared to existing facilities, the proposed facility will benefit from a lower electron beam energy, due to the enhanced undulators performance, and will be significantly more compact, with a smaller footprint, as a consequence of the lower energy and the high-gradient X-band structures. In addition, the whole infrastructure will also have a lower electrical power demand as well as lower construction and running costs

    A cusp electron gun for millimeter wave gyro-devices

    Get PDF
    A thermionic cusp electron gun has been designed, numerically optimized and experimentally measured and is presented. A 40 kV, 1.5 A annular axis-encircling electron beam has been simulated to generate a beam with low velocity and alpha spreads. The electron gun performance has been verified through experiments. Based on the measured results further improvement and optimization of the cusp gun for high frequency operation were carried out and the results will be presented

    Preliminary design of a G-band extended interaction oscillator driven by a sheet electron beam

    Get PDF
    A preliminary design of a G-band extended interaction oscillator (EIO) driven by a sheet electron beam is presented in this paper. PIC-3D simulations reveal that an output power of about 3.1 kW can be achieved when driven by a sheet electron beam with a voltage of 31.5 kV and a current of 0.85 A. The oscillation frequency is 197.3 GHz and the electronic efficiency is about 11.6%

    Self-calibration and motion recovery from silhouettes with two mirrors

    Get PDF
    LNCS v. 7724-7727 (pts. 1-4) entitled: Computer vision - ACCV 2012: 11th Asian Conference on Computer Vision ... 2012: revised selected papersThis paper addresses the problem of self-calibration and motion recovery from a single snapshot obtained under a setting of two mirrors. The mirrors are able to show five views of an object in one image. In this paper, the epipoles of the real and virtual cameras are firstly estimated from the intersection of the bitangent lines between corresponding images, from which we can easily derive the horizon of the camera plane. The imaged circular points and the angle between the mirrors can then be obtained from equal angles between the bitangent lines, by planar rectification. The silhouettes produced by reflections can be treated as a special circular motion sequence. With this observation, technique developed for calibrating a circular motion sequence can be exploited to simplify the calibration of a single-view two-mirror system. Different from the state-of-the-art approaches, only one snapshot is required in this work for self-calibrating a natural camera and recovering the poses of the two mirrors. This is more flexible than previous approaches which require at least two images. When more than a single image is available, each image can be calibrated independently and the problem of varying focal length does not complicate the calibration problem. After the calibration, the visual hull of the objects can be obtained from the silhouettes. Experimental results show the feasibility and the preciseness of the proposed approach. © 2013 Springer-Verlag.postprin

    Integrating Al with NiO nano honeycomb to realize an energetic material on silicon substrate

    Get PDF
    Nano energetic materials offer improved performance in energy release, ignition, and mechanical properties compared to their bulk or micro counterparts. In this study, the authors propose an approach to synthesize an Al/NiO based nano energetic material which is fully compatible with a microsystem. A two-dimensional NiO nano honeycomb is first realized by thermal oxidation of a Ni thin film deposited onto a silicon substrate by thermal evaporation. Then the NiO nano honeycomb is integrated with an Al that is deposited by thermal evaporation to realize an Al/NiO based nano energetic material. This approach has several advantages over previous investigations, such as lower ignition temperature, enhanced interfacial contact area, reduced impurities and Al oxidation, tailored dimensions, and easier integration into a microsystem to realize functional devices. The synthesized Al/NiO based nano energetic material is characterized by scanning electron microscopy, X-ray diffraction, differential thermal analysis, and differential scanning calorimetry

    Systematic uncertainties in the precise determination of the strangeness magnetic moment of the nucleon

    Get PDF
    Systematic uncertainties in the recent precise determination of the strangeness magnetic moment of the nucleon are identified and quantified. In summary, G_M^s = -0.046 \pm 0.019 \mu_N.Comment: Invited presentation at PAVI '04, International Workshop on Parity Violation and Hadronic Structure, Laboratoire de Physique Subatomique et de Cosmologie, Grenoble, France, June 8-11, 2004. 7 pages, 16 figure
    corecore