65 research outputs found

    АНАЛІЗ ДІАГНОСТИЧНИХ ПАРАМЕТРІВ ІМУНОБЛОТИНГУ ДЛЯ ВИЗНАЧЕННЯ СЕНСИБІЛІЗАЦІЇ ДО ПИЛКОВИХ АЛЕРГЕНІВ У ПАЦІЄНТІВ З РЕСПІРАТОРНИМИ ЗАХВОРЮВАННЯМИ

    Get PDF
    The aim of the study was to compare the diagnostic parameters of different systems of serological examination by immunoblot method for the determination of sensitization to allergens of pollen group in patients with respiratory allergic diseases – allergic rhinitis and bronchial asthma. Materials and methods. In the study, 88 patients with allergic rhinitis and/or atopic asthma were examined with three different methods of specific allergic diagnosis (in vivo and in vitro). Inclusion criteria were a diagnosis of allergic rhinitis (both intermittent and persistent) and/or atopic asthma. The pre-test was conducted according to the classic test method according to the normative documents with commercial allergen extracts. Western blots for the determination of IgE levels were performed using RIDA AllergyScreen test systems (R-Biopharm AG, Darmstadt, Germany) and Euroline (Euroimmun). Results and conclusions. The results of two systems for determining specific IgE for pollen allergens by the Rida AllergyScreen and Euroline methods do not always agree very well due to the systematic divergence of indicators. The results of determining specific IgE for individual allergens are generally in good agreement with each other and the results of skin testing by the prick test, however, for pollen, birch, hazel and alder pollen allergens, the Euroline system does not always match the results of skin testing by the prick test. negative results. Further analysis of the consistency and diagnostic parameters of the methods for other allergen groups is necessary to summarize all the results of the study.Метою дослідження було порівняти діагностичні параметри різних систем дослідження методом імуноблоту для визначення сенсибілізації до алергенів пилкової групи у пацієнтів з респіраторними захворюваннями – алергічним ринітом та бронхіальною астмою. Матеріали і методи. В ході дослідження 88 пацієнтів з алергічним ринітом і/або атопічною астмою були обстежені трьома різними методами специфічної алергічної діагностики (in vivo та in vitro). Критеріями включення були діагноз алергічного риніту (як інтермітуючого, так і персистуючого) та/або атопічної астми. Прик-тест проводився за класичною методикою тестування відповідно до нормативних документів з комерційними екстрактами алергенів. Вестерн-блот для визначення рівнів IgE проводили з використанням тест-систем RIDA AllergyScreen (R-Biopharm AG, Дармштадт, Німеччина) і Euroline (Euroimmun). Результати та висновки. Результати двох систем визначення специфічного IgE до алергенів пилкової групи методами Rida AllergyScreen та Euroline не завжди добре узгоджуються між собою внаслідок систематичної розбіжності показників. Результати визначення специфічних IgE до окремих алергенів в цілому добре узгоджуються між собою та з результатами шкірного тестування методом прик-тесту, втім до пилкових алергенів полину, берези, ліщини та вільхи система Euroline не завжди узгоджується з даними шкірного тестування методом прик-тесту, даючи хибно-негативні результати. Необхідний подальший аналіз узгодженості та діагностичних параметрів методів за іншими групами алергенів для узагальнення результатів дослідження

    Investigation of contamination caused by rubber compactor in arsine purified in gas centrifuge

    Get PDF
    In the process of studying the application of gas centrifuges for deep purification of arsine from impurities sulphur was found. Estimation of quantitative content of sulphur in pure arsine showed the value -10-4 wt. %. The sources of sulphur was stated to be rubber compactors forming gas centrifuge complex and made from rubber on the basis of butadiene_nitrile caoutchouc using sulfur cure. Using rubber compactors made from rubber produced from fluoroelastomers, not undergoing to sulfur cure one can provide sulphur content in pure product less than 10-5 wt. %

    Interaction between UN and CdCl2 in molten LiCl-KCl eutectic. I. Experiment at 773 K

    Full text link
    The interaction between UN and CdCl2 in the LiCl-KCl molten eutectic was studied at 773 K. The reaction was controlled by sampling the melt, as well as by analysis of the resulting precipitate. The process was shown to proceed according to several parallel reactions. The summary reaction was determined to have two stages: a fast one and a slow one. The 19–53% UN → UCl3 conversion was obtained for the molar ratio of CdCl2/UN = 1.22–14.9. The rest of UN converts into the precipitate of complex composition (UNCl + U2N3 + U4N7 + UN2). The increase in the CdCl2/UN molar ratio from 1.22 to 14.9 resulted in the decrease in duration of the first “fast” stage of the process from 18 h to 1 h. © 201

    Interaction between UN and CdCl2 in Molten LiCl–KCl Eutectic. II. Experiment at 1023 K

    Full text link
    The interaction between UN and CdCl2 in the LiCl–KCl molten eutectic was studied at 1023 K. The chlorination was monitored by sampling and recording the redox potential of the medium. At 1023 K the chlorination of UN with cadmium chloride in the molten LiCl–KCl eutectic proceeds completely and results in the formation of uranium chlorides. The melts of the LiCl–KCl–UCl3 or LiCl–KCl–UCl4 compositions can be obtained by the end of experiment depending on the presence of metallic cadmium in the reaction zone. The higher the concentration of the chlorinating agent, the faster the reaction rate. At [CdCl2]/[UN] = 1.65 (10% excess) the reaction proceeds to completion in about 7.5 h. At [CdCl2]/[UN] = 7 the complete chlorination takes 2.5–3 h. © 2021.The authors gratefully acknowledge for analytical support of the Shared Access Centre "Composition of Compounds" of the Institute of High Temperature Electrochemistry of the Ural Branch of the Russian Academy of Sciences. The present research was partially performed within the Proryv (Breakthrough) project of State Atomic Energy Corporation Rosatom

    ОПЫТ ИСПОЛЬЗОВАНИЯ КОМБИНАЦИИ РАДИОХИРУРГИИ И РЕЗЕКЦИИ ПЕЧЕНИ ПРИ ОБШИРНОМ МЕТАСТАТИЧЕСКОМ ПОРАЖЕНИИ

    Get PDF
    The paper presents the first experience of using a combination of radiosurgery and resection of the liver in patients with extensive metastatic disease treated at theChelyabinskRegionalOncologyCenter. This technique results no in postoperative liver failure, thus allowing R0 resection to be performed for unresectable patients.Представлен первый опыт использования на Урале комбинации радиохирургии и оперативного вмешательства при обширном метастатическом поражении. Данная методика позволяет проводить терапию, не боясь развития послеоперационной печеночной недостаточности, что дает возможность провести лечение в объеме R0 нерезектабельной группе больных

    Старейшина геологической съемки в Туве (к 80-летию С. С. Куликова)

    No full text
    Статья посвящена Сергею Сергеевичу Куликову, ветерану геологической службы Тувы, начальнику многих геологических партий, осуществлявших геологическую съёмку и поиски полезных ископаемых в различных районах республики

    Analysis of Relationship Between the Dynamics of a Thermoelectric Cooler and Its Design and Modes of Operation

    Full text link
    We examined a dynamic model of the relationship between basic parameters and indicators of reliability, taking into consideration the structural and technological elements, for a single-stage cooling device under various current modes of operation, thermal load at a temperature difference of 40 K. The ratios derived allow us to define the time required for a single-stage of thermoelectric cooling device to enter a stationary mode of operation, and the temperature of a heat-absorbing junction. The dependences take into consideration values of a thermal load, the number of thermoelements, current mode of operation, with respect to both the mass and heat capacity of the object, and the mass and heat capacity of structural and technological elements at heat-absorbing junctions of the module. It was found that the heat capacity and mass of structural and technological elements of the module affect not only the time required to enter a stationary mode, but the device's reliability indicators, reducing them by 2‒3 times. The results of analysis of dynamic characteristics and energy indicators of a single-stage thermoelectric cooler demonstrated the possibility to control the time required to enter a stationary mode. Structural control, enabled by selecting the number and geometry of the cooler's thermoelements, and the mass and heat capacity of the load, makes it possible to reduce the time required for a thermoelectric cooling device to enter a stationary mode by up to 2.5 times. Operational control, executed by changing working current of the cooler, makes it possible to reduce the time required to enter a stationary mode by up to 3 times
    corecore