261 research outputs found

    META-ANALYSIS OF RANDOMIZED CONTROLLED TRIALS: QUANTITATIVE ASPECTS

    Get PDF
    A meta-analysis combines the results of several studies that address a set of related research hypotheses. Meta-analyses has been taking place in the medical literature, specialy in systematic reviews of randomized control trials. Therefore, there is a need for more works on the underlying statistical methodology. Results from studies are combined using different statistical approaches. One approach frequently used in meta-analysis of randomized controlled trials considers that there is homogeneity across all studies. Regression models with fixed effects are compatible with this assumption. Other approach considers heterogeneity across the studies. Random effects regression models are used in this situation. The present article reviews some quantitative aspects of the meta-analysis.A metanálise é uma técnica que combina os resultados de diversos estudos voltados a um conjunto de hipóteses específicas. A metanálise vem sendo amplamente utilizada em estudos médicos, especialmente em revisões sistemáticas de ensaios clínicos aleatorizados. Há, portanto, a necessidade de estudos sobre as ferramentas estatísticas envolvidas. Os resultados dos estudos são combinados por diferentes estratégias. Uma alternativa considera homogeneidade entre os estudos. Modelos de regressão com efeitos fixos são compatíveis com este pressuposto. Por outro lado, se for assumida heterogeneidade entre os estudos, os modelos de efeitos aleatórios são mais adequados. O presente artigo revisa alguns aspectos quantitativos da metanálise

    A Journey into the European Supply Chains: Key Industries and Best Practices

    Get PDF
    Macro-trends and sectoral-specific evolutions are changing the way companies produce, distribute and build relationships in their supply network and with customers. Aiming to investigate the effective implementation of new supply chain concepts and innovation needs identified in the previous sections, this chapter provides a study of multiple cases of excellence among European supply chains. It depicts an overview of major trends and structural features of 8 key industries for European economy, i.e. Automotive, Aerospace, Fashion, Chemical, IT, Distribution/logistics, Furniture, Food and Beverage. For each industry, a structured investigation into one or more companies was performed with a total of 18 companies involved. The results identify possible matchings in relation to supply chain strategies, and good and best practices adopted accordingl

    Short-term forecasting of daily COVID-19 cases in Brazil by using the Holt’s model

    Get PDF
    Introduction: We evaluated the performance of the Holt’s model to forecast the daily COVID-19 reported cases in Brazil and three Brazilian states. Methods: We chose the date of the first COVID-19 case to April 25, 2020, as the training period, and April 26 to May 3, 2020, as the test period. Results: The Holt’s model performed well in forecasting the cases in Brazil and in São Paulo and Minas Gerais states, but the forecasts were underestimated in Rio de Janeiro state. Conclusions: The Holt’s model can be an adequate shortterm forecasting method if their assumptions are adequately verified and validated by experts

    Construct validity of a Portuguese version of the Female Sexual Function Index

    Get PDF
    Este trabalho teve como objetivos avaliar a validade de construto de uma versão do Female Sexual Function Index (FSFI). A versão foi inserida ao final de um questionário multidimensional e aplicada face a face em 235 mulheres esterilizadas. O índice de não resposta foi de 1,7%. A amostra apresentou-se bastante homogênea com baixa renda e nível educacional. Um coeficiente alfa de Cronbach de 0,948 indicou uma consistência interna muito alta. A análise fatorial demonstrou que o instrumento parece medir quatro fatores latentes: desejo/excitação, lubrificação, orgasmo/satisfação e dor. Isso pode referir-se a uma característica do próprio instrumento, às características da resposta sexual feminina ou ainda às peculiaridades culturais da amostra, o que pode interferir no entendimento das perguntas ou dos conceitos sobre os quais o instrumento versa. Assim aponta-se para necessidade de desenvolvimento de outros estudos na população geral para a definição do conjunto de propriedades do FSFI, como sua composição de fatores latentes e o estabelecimento de pontos de corte adequados à população brasileira.This study aimed to evaluate the construct validity of a version of the Female Sexual Function Index (FSFI). The version was inserted into a multidimensional questionnaire and applied face-to-face to 235 sterilized women. Non-response rate was 1.7%. The sample proved to be highly homogeneous, with low income and education. Cronbach's alpha of 0.948 indicated high internal consistency. Factor analysis showed that the instrument was measuring four factors: desire/arousal, lubrication, orgasm/satisfaction, and pain. This may reflect characteristics of the instrument itself, female sexual response, or even the sample's cultural peculiarities, which can affect understanding of the questions or concepts with which the instrument deals. This study emphasizes the need for further research in the general population to determine the psychometric properties of the FSFI, such as its factor composition and definition of appropriate cut-off points for the Brazilian population.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP

    Free radical polymerization photoinitiated of multicomponent systems for us e in ophthalmic devices : optical and mechanical aspects

    Get PDF
    Orientador: Edison BittencourtTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia QuimicaResumo: 0 mercado atual procura por materiais que apresentem boas propriedades ópticas, que satisfaçam os consumidores e os usuários em geral e que sejam de fácil manuseio e processabilidade. No geral, um polímero deve apresentar boas propriedades ópticas, resistência ao impacto e dureza, compatíveis com o seu uso como lentes oftálmicas. O processo de fabricação de lentes oftálmicas poliméricas por muito tempo foi feito por meio de processos térmicos (cura térmica, processo que ainda é usado), levando cerca de 20 horas ou mais na obtenção de lentes que não apresentassem problemas de trincas por diferença de propriedades no corpo da lente. Dessa forma a introdução da tecnologia de cura pela luz ultravioleta (UV) permitiu a obtenção de materiais com a mesma característica e até superiores aquelas obtidas através da cura térmica e com a vantagem da diminuição do tempo de processo, diminuindo de horas para minutos, resultando também em redução dos custos. Neste trabalho foram utilizados os monômeros e oligômeros listados a seguir: metil metacrilato de metila (MAM), 1,6-Hexanediol diacrilato (HDDMA), diacrilato uretano alifático tetrafuncional (Ebecryl 5129) e diacrilato epóxi bisfenol-A (Ebecryl 3700) e em cada formulação foi aplicado um sistema de fotoiniciadores (nomes comerciais) compostos por Darocur 1173, Irgacure 184, Irgacure 1300, Irgacure 2959 e Irgacure 250 e Irgacure 819. Os sistemas de fotoiniciadores foram formulados a base de 3% p/p sobre cada formulação, seguindo as orientações dos fornecedores e de resultados experimentais obtidos ao longo deste estudo, sendo o tempo de cura da formulação de 7 minutos. Foram analisadas as propriedades mecânicas relevantes que uma lente deve apresentar, entre elas, dureza e resistência ao impacto. Foram determinadas também as temperaturas de transição vítrea obtidas da formulação, e a resistência ao calor. Foram comparados com os diversos fotoiniciadores, e realizado um estudo inicial da cinética, bem como medidas as entalpias e conversões resultantes da polimerização na temperatura de trabalho de 100°C, utilizando-se um fotocalorímetro diferencial de varredura (DPC).Abstract: The current market calls for materials presenting good optical properties which satisfy consumers and users in general and that can be easily handled and processed. Generally, a polymer must present good optical properties, impact resistance and hardness - all compatible in their use as ophthalmic lenses. For quite a long period of time, ophthalmic lenses manufacturing had been achieved by means of thermal processes (thermal curing), taking up to 20 hours to obtain lenses free of cracking and/or processing errors. In this manner, the introduction of ultraviolet light curing technology has allowed the production of materials with equal and even superior characteristics than those obtained through thermal curing, and with advantages in processing time (reduced from hours to minutes), as well as costs, which were also reduced. The following monomers and oligomers were utilized in this study: methyl methacrylate (MAM), 1,6-Hexanediol diacrylate (HDDMA), diacrylate tetra functional aliphatic urethane (Ebecryl 5129) and epoxy diacrylate bisphenol A (Ebecryl 3700-20 t). A system of photoinitiators composed by darocur 1173, Irgacure 184, Irgacure 1300, Irgacure 2959, Irgacure 250 and Irgacure 819 have been applied in each formulation. The photoinitiators systems have been formulated on a 3% p/p basis, following suppliers orientations and experimental results obtained throughout this study, with a 7-minute formulation curing time. The main mechanical properties a lens must present, such as acceptable harness and impact resistance, were analyzed in the study. Vitreous transition temperature, heat resistance and the evaluation of the photoinitiators in kinetics have been analyzed and studied, as well as the evolution of enthalpy during a 100°C polymerization process and formulation conversions by differential photocalorimetry distinguishing (DPC).DoutoradoCiencia e Tecnologia de MateriaisDoutor em Engenharia Químic

    Estimação bayesiana das medidas do desempenho da colpocitologia oncologica, captura hibrida II e inspeção visual com acido acetico em detectar lesões cervicais pre neoplasicas e neoplasicas

    Get PDF
    Orientador: Francisco Louzada-Neto, Sophie Françoise Mauricette DerchainTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias MedicasDoutorad

    Um modelo SARIMA para predição do número de casos de dengue em Campinas, Estado de São Paulo

    Get PDF
    INTRODUCTION: Forecasting dengue cases in a population by using time-series models can provide useful information that can be used to facilitate the planning of public health interventions. The objective of this article was to develop a forecasting model for dengue incidence in Campinas, southeast Brazil, considering the Box-Jenkins modeling approach. METHODS: The forecasting model for dengue incidence was performed with R software using the seasonal autoregressive integrated moving average (SARIMA) model. We fitted a model based on the reported monthly incidence of dengue from 1998 to 2008, and we validated the model using the data collected between January and December of 2009. RESULTS: SARIMA (2,1,2) (1,1,1)12 was the model with the best fit for data. This model indicated that the number of dengue cases in a given month can be estimated by the number of dengue cases occurring one, two and twelve months prior. The predicted values for 2009 are relatively close to the observed values. CONCLUSIONS: The results of this article indicate that SARIMA models are useful tools for monitoring dengue incidence. We also observe that the SARIMA model is capable of representing with relative precision the number of cases in a next year.INTRODUÇÃO: A predição do número de casos de dengue em uma população utilizando modelos de series temporais pode trazer informações úteis para um melhor planejamento de intervenções públicas de saúde. O objetivo deste artigo é desenvolver um modelo capaz de descrever e predizer a incidência de dengue em Campinas, sudeste do Brasil, considerando a metodologia de Box e Jenkins. MÉTODOS: O modelo seasonal autoregressive integrated moving average (SARIMA) para os dados de incidência de dengue em Campinas, foi implementado no programa R. Ajustamos um modelo baseado na incidência mensal notificada da doença de 1998 a 2008 e validado pelos dados de janeiro a dezembro de 2009. RESULTADOS: O modelo SARIMA (2,1,2) (1,1,1)12 foi o mais adequado aos dados. Este modelo indicou que o número de casos de dengue em um dado mês pode ser estimado pelo número de casos ocorridos há um, dois e doze meses. Os valores preditos para 2009 são relativamente próximos aos valores observados. CONCLUSÕES: Os resultados deste artigo indicam que os modelos SARIMA são ferramentas úteis para o monitoramento da incidência da dengue. Observamos ainda que o modelo SARIMA é capaz de representar com relativa precisão o número de casos de dengue em um ano consecutivo à série de dados usada no ajuste do modelo

    Métodos ativos de aquecimento cutâneo para a prevenção de hipotermia no período intraoperatório: revisão sistemática

    Get PDF
    This study analyzed the evidence available in the literature concerning the effectiveness of different active cutaneous warming systems to prevent intraoperative hypothermia. This is a systematic review with primary studies found in the following databases: CINAHL, EMBASE, Cochrane Register of Controlled Trials and Medline. The sample comprised 23 randomized controlled trials. There is evidence in the literature indicating that the circulating water garment system is the most effective in maintaining patient body temperature. These results can support nurses in the decision-making process concerning the implementation of effective measures to maintain normothermia, though the decision of health services concerning which system to choose should also take into account its cost-benefit status given the cost related to the acquisition of such systems.La finalidad del estudio fue analizar las evidencias disponibles en la literatura acerca de la efectividad de los diferentes métodos activos de calentamiento cutáneo para la prevención de hipotermia en el período intraoperatorio. Para esto, la revisión sistemática fue usada como método de revisión. La búsqueda de los estudios primarios fue efectuada en las bases de datos CINAHL, EMBASE, Cochrane Register of Controlled Trials y Medline. La muestra de la revisión abarcó 23 ensayos clínicos aleatorios controlados. La literatura ofrece evidencias que indican que el sistema de circulación de agua calentada es el método más efectivo en la manutención de la temperatura corporal. Los resultados evidenciados pueden subsidiar la toma de decisión del enfermero en la implementación de medidas efectivas para la manutención de la temperatura corporal. Sin embargo, considerando los costos de adquisición de los sistemas investigados, la elección del sistema en cada servicio de salud debería ser basada en el análisis de costo-beneficio.O estudo teve como objetivo analisar as evidências disponíveis na literatura sobre a efetividade dos diferentes métodos ativos de aquecimento cutâneo, para a prevenção de hipotermia no período intraoperatório. Para tal, a revisão sistemática foi empregada como método de revisão. A busca por estudos primários foi realizada nas bases de dados CINAHL, EMBASE, Cochrane Register of Controlled Trials e MEDLINE. A amostra da revisão foi composta por 23 ensaios clínicos randomizados controlados. Na literatura, há evidências que indicam que o sistema de circulação de água aquecida é o método mais efetivo à manutenção da temperatura corporal. Os resultados evidenciados podem subsidiar a tomada de decisão do enfermeiro na implementação de medidas efetivas para a manutenção da temperatura corporal. Recomenda-se, entretanto, que a escolha do sistema em cada serviço de saúde seja também baseada na análise custo/benefício, devido aos custos relativos à aquisição dos sistemas investigados

    Efeito do pré-aquecimento na manutenção da temperatura corporal do paciente cirúrgico: ensaio clínico randomizado

    Get PDF
    Objetivo: evaluar el efecto del pre-calentamiento en el mantenimiento de la temperatura corporal de pacientes sometidas a cirugías ginecológicas electivas. Método: 86 pacientes fueron aleatorizados, sin ceguera, para recibir cuidado usual (calentamiento con sábanas de algodón y manta) o pre-calentamiento con el uso del sistema de aire forzado calentado, durante 20 minutos (38°C). Todas las pacientes fueron calentadas de forma activa durante el período intraoperatorio. Los datos fueron recogidos de la admisión de la paciente en el centro quirúrgico hasta el final de la cirugía. La temperatura corporal fue medida durante los períodos pre e intraoperatorio con un termómetro timpánico infrarrojo. Para la temperatura y humedad del aire de la sala quirúrgica, se utilizó el termo-higrómetro. Resultados: los datos indicaron homogeneidad entre los grupos investigados. No hubo diferencia estadísticamente significante entre los grupos después del pre-calentamiento (p=0,27). Al final de la cirugía, la temperatura media de los grupos estudiados fue igual (36,8°C), con diferencia estadísticamente no significante (p=0,66). Conclusión: el pre-calentamiento con el sistema de aire forzado calentado tuvo efecto semejante al cuidado usual en la temperatura corporal de pacientes sometidas a cirugías ginecológicas electivas. ClinicalTrials.gov n. NCT02422758. CAAE, n. 38320814.2.0000.5393.Objetivo: avaliar o efeito do pré-aquecimento na manutenção da temperatura corporal de pacientes submetidas a cirurgias ginecológicas eletivas. Método: foram randomizadas 86 pacientes, sem cegamento, para receber cuidado usual (aquecimento com lençol de algodão e cobertor) ou pré-aquecimento com o uso do sistema de ar forçado aquecido, durante 20 minutos (38°C). Todas as pacientes foram aquecidas de forma ativa durante o período intraoperatório. Os dados foram coletados da admissão da paciente no centro cirúrgico até o final da cirurgia. A temperatura corporal foi mensurada durante os períodos pré e intraoperatório com termômetro timpânico infravermelho. Para a temperatura e umidade do ar da sala cirúrgica, utilizou-se o termo-higrômetro. Resultados: os dados indicaram homogeneidade entre os grupos investigados. Não houve diferença estatisticamente significante entre os grupos após o pré-aquecimento (p=0,27). Ao final da cirurgia, a temperatura média dos grupos estudados foi igual (36,8°C), com diferença estatisticamente não significante (p=0,66). Conclusão: o pré-aquecimento com o sistema de ar forçado aquecido teve efeito semelhante ao cuidado usual na temperatura corporal de pacientes submetidas a cirurgias ginecológicas eletivas. ClinicalTrials.gov n. NCT02422758. CAAE, n. 38320814.2.0000.5393.Objective: to evaluate the effect of preheating on the maintenance of body temperature of patients submitted to elective gynecological surgeries. Method: eighty-six patients were randomized, without blinding, to receive usual care (heating with a cotton sheet and blanket) or preheating with a forced air system for 20 minutes (38°C). All patients were actively heated during the intraoperative period. Data were collected from admission of the patient in the surgical center until the end of the surgery. Body temperature was measured during the preoperative and intraoperative periods with an infrared tympanic thermometer. A thermo-hygrometer was used to monitor air temperature and humidity of the operating room. Results: data indicated homogeneity between the groups investigated. There was no statistically significant difference between groups after preheating (p = 0.27). At the end of the surgery, the mean temperature of the groups studied was the same (36.8°C), with a statistically non-significant difference (p = 0.66). Conclusion: preheating with the heated forced air system had a similar effect to the usual care in the body temperature of patients submitted to elective gynecological surgeries. ClinicalTrials.gov n. NCT02422758. CAAE, n. 38320814.2.0000.5393
    • …
    corecore